Background: Atrioventricular block (AVB) is a frequent initial presentation of cardiac sarcoidosis (CS), but dangerous ventricular arrhythmias (VA) can occur. Despite the scarcity of data, guidelines recommend implantable cardioverter-defibrillator (ICD) rather than a pacemaker implantation whenever a device is needed.
Objective: In this study, we aimed to establish predictors for sustained VA in patients with CS presenting with pacing indication because of an AVB.
Purpose Of Review: Cardiovascular magnetic resonance (CMR) imaging excels in providing detailed three-dimensional anatomical information together with excellent soft tissue contrast and has already become a valuable tool for diagnostic evaluation, electrophysiological procedure (EP) planning, and therapeutical stratification of atrial or ventricular rhythm disorders. CMR-based identification of ablation targets may significantly impact existing concepts of interventional electrophysiology. In order to exploit the inherent advantages of CMR imaging to the fullest, CMR-guided ablation procedures (EP-CMR) are justly considered the ultimate goal.
View Article and Find Full Text PDFAims: High-power-short-duration (HPSD) ablation is an effective treatment for atrial fibrillation but poses risks of thermal injuries to the oesophagus and vagus nerve. This study aims to investigate incidence and predictors of thermal injuries, employing machine learning.
Methods And Results: A prospective observational study was conducted at Leipzig Heart Centre, Germany, excluding patients with multiple prior ablations.
Fully CMR-guided electrophysiological interventions (EP-CMR) have recently been introduced but data on the optimal CMR imaging protocol are scarce. This study determined the clinical utility of 3D non-selective whole heart steady-state free precession imaging using compressed SENSE (nsWHcs) for automatic segmentation of cardiac cavities as the basis for targeted catheter navigation during EP-CMR cavo-tricuspid isthmus ablation. Fourty-two consecutive patients with isthmus-dependent right atrial flutter underwent EP-CMR radiofrequency ablations.
View Article and Find Full Text PDF[This corrects the article DOI: 10.3389/fcvm.2023.
View Article and Find Full Text PDFAims: Low-voltage areas (LVAs) found during left atrial (LA) electroanatomical mapping are increasingly targeted by radiofrequency catheter ablation (RFCA) on top of pulmonary vein isolation to improve arrhythmia-free survival in patients with atrial fibrillation (AF). However, pre-procedural prediction of LVAs remains challenging. The purpose of the present study was to describe the association between parameters of LA function and dimensions, respectively, derived from pre-procedural cardiovascular magnetic resonance (CMR) imaging, and the presence of LVAs on LA voltage mapping.
View Article and Find Full Text PDFPurpose: Mitral valve prolapse (MVP) is associated with left ventricle (LV) fibrosis, including the papillary muscles (PM), which is in turn linked to malignant arrhythmias. This study aims to evaluate comprehensive tissue characterization of the PM by cardiovascular magnetic resonance (CMR) imaging and its association with LV fibrosis observed by intraoperative biopsies.
Methods: MVP patients with indication for surgery due to severe mitral regurgitation (n = 19) underwent a preoperative CMR with characterization of the PM: dark-appearance on cine, T1 mapping, conventional bright blood (BB) and dark blood (DB) late gadolinium enhancement (LGE).
Purpose: Mitral valve prolapse (MVP) is associated with left ventricle (LV) fibrosis, including the papillary muscles (PM), which is in turn linked to malignant arrhythmias. This study aims to evaluate comprehensive tissue characterization of the PM by cardiovascular magnetic resonance (CMR) imaging and its association with LV fibrosis observed by intraoperative biopsies.
Methods: MVP patients with indication for surgery due to severe mitral regurgitation (n=19) underwent a preoperative CMR with characterization of the PM: dark-appearance on cine, T1 mapping, conventional bright blood (BB) and dark blood (DB) late gadolinium enhancement (LGE).
Cardiac sarcoidosis can mimic any cardiomyopathy in different stages. Noncaseating granulomatous inflammation can be missed, because of the nonhomogeneous distribution in the heart. The current diagnostic criteria show discrepancies and are partly nonspecific and insensitive.
View Article and Find Full Text PDFBackground: Cardiovascular magnetic resonance (CMR) imaging allows to combine pulmonary perfusion measurements and pulmonary venous angiography during a single-session examination with both imaging modules representing the basis for accurate diagnosis and therapeutic stratification of pulmonary vein (PV) stenosis. The present study investigated the clinical utility of dynamic pulmonary perfusion imaging integrated into a comprehensive CMR protocol for the evaluation of patients with suspected PV stenosis.
Methods: 162 patients with clinically suspected PV stenosis after catheter ablation of atrial fibrillation underwent a combined single-session CMR examination (cardiac cine imaging, dynamic pulmonary perfusion, and three-dimensional PV angiography).
Purpose: To evaluate a silent MR active catheter tracking sequence that allows conducting catheter interventions with low acoustic noise levels.
Methods: To reduce the acoustic noise associated with MR catheter tracking, we implemented a technique previously used in conventional MRI. The gradient waveforms are modified to reduce the sound pressure level (SPL) and avoid acoustic resonances of the MRI system.
Aims: Left bundle branch area pacing (LBBAP) can be technically challenging and fluoroscopy-intense. Three-dimensional electroanatomical mapping (EAM) facilitates non-fluoroscopic lead navigation and electrogram mapping. We sought to prospectively evaluate the feasibility, safety, and outcomes of routine EAM-guided LBBAP in patients with structural heart disease (SHD) and advanced conduction abnormalities.
View Article and Find Full Text PDFBackground: Pulmonary vein (PV) stenosis represents a rare but serious complication following radiofrequency ablation of atrial fibrillation with a comprehensive diagnosis including morphological stenosis grading together with the assessment of its functional consequences being imperative within the relatively narrow window for therapeutic intervention. The present study determined the clinical utility of a combined, single-session cardiovascular magnetic resonance (CMR) imaging protocol integrating pulmonary perfusion and PV angiographic assessment for pre-procedural planning and follow-up of patients referred for interventional PV stenosis treatment.
Methods: CMR examinations (cine imaging, dynamic pulmonary perfusion, three-dimensional PV angiography) were performed in 32 consecutive patients prior to interventional treatment of PV stenosis and at 1-day and 3-months follow-up.
Objectives: In patients of advanced age, the feasibility of myocardial ischemia testing might be limited by age-related comorbidities and falling compliance abilities. Therefore, we aimed to test the accuracy of 3D cardiac magnetic resonance (CMR) stress perfusion in the elderly population as compared to reference standard fractional flow reserve (FFR).
Methods: Fifty-six patients at age 75 years or older (mean age 79 ± 4 years, 35 male) underwent 3D CMR perfusion imaging and invasive coronary angiography with FFR in 5 centers using the same study protocol.
Cardiac magnetic resonance imaging (cMRI) now rates among the established diagnostic procedures for the clarification of cardiac disease patterns. In modern clinical electrophysiology, apart from providing basic cardiac diagnostics of patients prior to interventional procedures, the imaging method enables the three-dimensional reconstruction of cardiac target structures of the planned ablation procedure, which can significantly improve the safety and efficacy of the intervention. Furthermore, cMRI has a high significance with respect to risk stratification during implantable cardioverter defibrillator (ICD) evaluation.
View Article and Find Full Text PDFIntroduction: Preprocedural cardiovascular magnetic resonance (CMR) or computed tomography (CT) imaging of the left atrium/pulmonary veins is usually employed to guide catheter ablation of atrial fibrillation (AFCA). Incidental findings (IFs) are common on cardiac imaging prior to AFCA. However, previous studies have mainly focused on extracardiac IFs detected on CT scan.
View Article and Find Full Text PDFFluoroscopy-based catheter ablation has established itself as a standard procedure for the treatment of patients with cardiac arrhythmias. However, it is subject to certain limitations with regard to the visualization of arrhythmogenic substrate and ablation lesions and is associated with radiation exposure. Within the framework of studies, initial experience with MRI-based, radiation-free electrophysiological examinations and ablations could be gained.
View Article and Find Full Text PDFA 25-year-old male patient with highly symptomatic, monomorphic, premature ventricular contractions presented for repeat ablation after failed endocardial ablation. Three weeks after excessive endocardial and epicardial ablation on the left ventricular summit, the patient was admitted again with tamponade following a pseudoaneurysm on the ablation site. ().
View Article and Find Full Text PDFAims: To establish a cardiovascular magnetic resonance (CMR)-based prediction model for complete systolic left ventricular ejection fraction (LVEF) recovery for the distinction of 'arrhythmia-induced' from 'arrhythmia-mediated' cardiomyopathy in patients with atrial tachyarrhythmias.
Methods And Results: Two hundred and fifty-three tachyarrhythmia patients referred for catheter ablation were enrolled and underwent CMR baseline imaging; patients with a reduced LVEF <50% at baseline and CMR imaging at 3-month follow-up after successful rhythm restoration constituted the final study population (n = 134). CMR at baseline consisted of standard functional cine imaging, determination of extracellular volume, and late gadolinium enhancement (LGE) imaging; follow-up CMR comprised standard functional cine imaging.
Background: Four-dimensional cardiovascular magnetic resonance (CMR) flow assessment (4D flow) allows to derive volumetric quantitative parameters in mitral regurgitation (MR) using retrospective valve tracking. However, prior studies have been conducted in functional MR or in patients with congenital heart disease, thus, data regarding the usefulness of 4D flow CMR in case of a valve pathology like mitral valve prolapse (MVP) are scarce. This study aimed to evaluate the clinical utility of cine-guided valve segmentation of 4D flow CMR in assessment of MR in MVP when compared to standardized routine CMR and transthoracic echocardiography (TTE).
View Article and Find Full Text PDFBackground: Interventricular septal perforation is an extremely rare complication of radiofrequency ablation (RFA), with an incidence of 1%. The most common mechanism is a 'steam pop', which can be described as 'mini-explosions' of gas bubbles. Data for percutaneous repair of cardiac perforations due to RFA are limited.
View Article and Find Full Text PDFThree-dimensional transthoracic echocardiography (3D-TTE) provides a semi-automated proximal isovelocity surface area method (3D-PISA) to obtain quantitative parameters. Data assessing regurgitation severity in mitral valve prolapse (MVP) are scarce, so we assessed the 3D-PISA method compared with 2D-PISA and cardiovascular magnetic resonance (CMR) and the role of an eccentricity index. We evaluated the 3D-PISA method for assessing MR in 54 patients with MVP (57 ± 14 years; 42 men; 12 mild/mild-moderate; 12 moderate-severe; and 30 severe MR).
View Article and Find Full Text PDFAims: Conventional His bundle pacing (HBP) can be technically challenging and fluoroscopy-intense, particularly in patients with His-Purkinje conduction disease (HPCD). Three-dimensional electroanatomical mapping (EAM) facilitates non-fluoroscopic lead navigation and HB electrogram mapping. We sought to assess the procedural outcome of routine EAM-guided HBP compared with conventional HBP in a real-world population and evaluate the feasibility and safety of EAM-guided HBP in patients with HPCD.
View Article and Find Full Text PDFBackground: Patients with cardiac implantable electronic devices (CIED) necessitate comprehensive cardiovascular magnetic resonance (CMR) examinations. The aim of this study was to provide data on CMR image quality and feasibility of functional assessment of the right heart in patients with CIED depending on the device type and imaging sequence used.
Methods: 120 CIED carriers (Insertable cardiac monitoring system, n = 13; implantable loop-recorder, n = 22; pacemaker, n = 30; implantable cardioverter-defibrillator (ICD), n = 43; and cardiac resynchronization therapy defibrillator (CRT-D), n = 12) underwent clinically indicated CMR imaging using a 1.