Publications by authors named "Pablo Sanz-Ruiz"

Background: Effective surgical wound management in total knee arthroplasty (TKA) is crucial for optimal healing and patient outcomes. Despite surgical advances, managing wounds to prevent complications remains challenging. This study aimed to identify and address evidence gaps in TKA wound management, including preoperative optimization, intraoperative options, and postoperative complication avoidance.

View Article and Find Full Text PDF

Rifampicin is one of the mainstays in treating staphylococcal prosthetic joint infection (PJI). However, discontinuation due to intolerance, drug interactions, and adverse events is common. Two-stage revision surgery remains the gold standard, with the number of revision arthroplasties steadily increasing.

View Article and Find Full Text PDF

Cylindrical fully-coated cobalt-chromium stems (CCS) have been widely used in femoral revisions. However, monoblock fluted conical tapered stems (FCTS) are growing in popularity. The present study seeks to determine whether there are any long-term differences between the two designs.

View Article and Find Full Text PDF

Background: This modified Delphi study aimed to develop a consensus on optimal wound closure and incision management strategies for total hip arthroplasty (THA). Given the critical nature of wound care and incision management in influencing patient outcomes, this study sought to synthesize evidence-based best practices for wound care in THA procedures.

Methods: An international panel of 20 orthopedic surgeons from Europe, Canada, and the United States evaluated a targeted literature review of 18 statements (14 specific to THA and 4 related to both THA and total knee arthroplasty).

View Article and Find Full Text PDF

Background: The purpose of this modified Delphi study was to obtain consensus on wound closure and dressing management in total knee arthroplasty (TKA).

Methods: The Delphi panel included 20 orthopaedic surgeons from Europe and North America. There were 26 statements identified using a targeted literature review.

View Article and Find Full Text PDF

Background: The rising incidence and complexity of revision knee arthroplasty has led to an increase in the use of metaphyseal reconstruction systems. One of the most widely used systems are metaphyseal sleeves as they have demonstrated excellent long-term survival. However, there is concern about the possible difficulty of extracting a sleeve if it were necessary, as no known procedures have yet been validated.

View Article and Find Full Text PDF
Article Synopsis
  • The study compares the tibial rotation between two types of knee implants: rotating hinge knee prostheses and constrained condylar prostheses, focusing on clinical outcomes in revision knee arthroplasty.
  • It included 20 patients, with 10 receiving each type of prosthesis, and tibial rotation was measured at various degrees of knee flexion using accelerometers.
  • Results showed that the rotating hinge knee group had significantly higher tibial rotation and better postoperative Knee Injury and Osteoarthritis Outcome Scores, suggesting it may offer greater clinical satisfaction due to its lower rotational constraint.
View Article and Find Full Text PDF

Irrigation and debridement using an irrigation solution is a fundamental step during the surgical treatment of both acute and chronic periprosthetic joint infection (PJI). However, there is no consensus on the optimal solution, nor is there sufficient evidence on the optimal irrigation time and combination of solutions. Therefore, it is necessary to determine which solution or combination of solutions is most efficacious against biofilm, as well as the optimal irrigation time.

View Article and Find Full Text PDF

Based on previous studies by our group in which we demonstrated that dalbavancin loaded in bone cement had good elution capacity for the treatment of biofilm-related periprosthetic infections, we now assess the anti-biofilm activity of dalbavancin and compare it with that of vancomycin over a 3-month period. We designed an in vitro model in which we calculated the percentage reduction in log cfu/mL counts of sonicated steel discs contaminated with staphylococci and further exposed to bone cement discs loaded with 2.5% or 5% vancomycin and dalbavancin at various timepoints (24 h, 48 h, 1 week, 2 weeks, 6 weeks, and 3 months).

View Article and Find Full Text PDF

Background: Two-stage exchange is a frequently performed procedure in patients who have a periprosthetic joint infection. Positive cultures when performing the second stage are perceived as a risk factor for reinfection. This study aimed to determine the impact of positive cultures during the second stage on the outcome of patients undergoing a 2-stage septic exchange and the impact of stopping the antibiotic treatment before reimplantation.

View Article and Find Full Text PDF

The use of additive manufacturing or 3D printing in biomedicine has experienced fast growth in the last few years, becoming a promising tool in pharmaceutical development and manufacturing, especially in parenteral formulations and implantable drug delivery systems (IDDSs). Periprosthetic joint infections (PJIs) are a common complication in arthroplasties, with a prevalence of over 4%. There is still no treatment that fully covers the need for preventing and treating biofilm formation.

View Article and Find Full Text PDF

Necrotizing fasciitis is a rare soft tissue infection that requires immediate medical attention to prevent its fulminant development that can lead to amputation or death of the patient. In most of reported cases of multifocal necrotizing fasciitis, injuries appear synchronously within hours from the initial diagnosis. It is the only third reported case with metachronous lesions, and the first that involves both S.

View Article and Find Full Text PDF

Antibiotic-loaded bone cement is the most widely used approach for the treatment of biofilm-induced septic sequelae in orthopedic surgery. Dalbavancin is a lipoglycopeptide that acts against Gram-positive bacteria and has a long half-life, so we aimed to assess whether it could be a new alternative drug in antibiotic-loaded bone cement for the treatment of periprosthetic joint infections. We assessed the elution capacity of dalbavancin and compared it with that of vancomycin in bone cement.

View Article and Find Full Text PDF

Prosthetic joint infection (PJI) is one of the most devastating complications of orthopedic surgery. However, not all patients are equally at the risk of severe infection. The incidences of PJI vary with the host and surgery-related risk factors.

View Article and Find Full Text PDF

Introduction: Reconstruction of acetabular bone defects by the combination of trabecular metal augments and porous cups can be complex when extensive bone loss and poor-quality bone exists. The onset of porous cups with an interlocking mechanism may simplify surgical technique due to its superior initial mechanical stability. We endorse the possibility for a change in the classical order of setting of the augments and the cup.

View Article and Find Full Text PDF

Introduction: The correct positioning of the implant in revision total hip arthroplasty (rTHA) is critical to obtaining substantial functional outcomes, and to avoiding complications. Current literature supports three-dimensional (3D)-printed models as potentially useful tools for preplanning, as well as the "do it yourself (DIY)" methodology to reduce both the time and costs of this procedure. However, no study has determined the efficacy of both methods combined in a cohort of patients with severe acetabular defects.

View Article and Find Full Text PDF

This study describes a new ultrasound-guided surgical technique for aponeurotomy and interphalangeal joint capsular release in patients with Dupuytren's disease and analyses the clinical outcomes. We carried out a retrospective review of 70 digits in 35 patients who underwent ultrasound-guided aponeurotomy and interphalangeal joint capsular release, with a minimum follow-up of 2 years. The primary outcome was the correction of the deformity and the QuickDASH questionnaire score after surgery and at 1 and 2 years.

View Article and Find Full Text PDF

Background: The appropriate degree of constraint in knee prosthetic revision is unknown, necessitating the use of the lowest possible constraint. This study aimed to compare the long-term clinical and survival results of revision with rotation hinge knee (RHK) VS constrained condylar constrained knee (CCK) implants.

Methods: Overall, 117 revision case were prospectively reviewed and dividing into two groups based on the degree of constraint used, using only one prosthetic model in each group (61 CCK vs 56 RHK).

View Article and Find Full Text PDF

Purpose: Microencapsulation techniques have allowed the addition of rifampicin to bone cement, but its in vivo efficacy has not been proven. The aim of our study is to determine the superiority of cement containing gentamicin and rifampicin microcapsules in the treatment of PJI versus cement exclusively containing gentamicin.

Methods: An S.

View Article and Find Full Text PDF

Background: Greater trochanteric pain syndrome encompasses a range of causes of lateral hip pain including greater trochanteric bursitis, tendinopathy and tears of the gluteus minimus and medius, and lateral snapping hip (LSH). Surgical options for LSH range from open surgery to endoscopic surgery, including a diamond-shaped cut or a simple transversal release to gluteus maximus tendon release. Resection of an area of proximal iliotibial band (ITB) and step-cut or z-plasty lengthening have not proven superior to transverse release of the ITB.

View Article and Find Full Text PDF

Background: 3D printing technology in hospitals facilitates production models such as point-of-care manufacturing. Orthopedic Surgery and Traumatology is the specialty that can most benefit from the advantages of these tools. The purpose of this study is to present the results of the integration of 3D printing technology in a Department of Orthopedic Surgery and Traumatology and to identify the productive model of the point-of-care manufacturing as a paradigm of personalized medicine.

View Article and Find Full Text PDF

Background: Iliotibial band (ITB) syndrome is the most common cause of lateral knee pain in runners (affecting 7-14%) and in persons taking part in other sports. The aim of this study was to show how to perform a distal release of the ITB guided by ultrasound and present our initial results with this new technique.

Methods: The surgical technique - either Z-plasty or transverse section of the ITB - was first validated on 14 cadaver specimens and then applied in clinical practice.

View Article and Find Full Text PDF