The CITIUS detector is a next-generation high-speed X-ray imaging detector. It has integrating-type pixels and is designed to show a consistent linear response at a frame rate of 17.4 kHz, which results in a saturation count rate of over 30 Mcps pixel when operating at an acquisition duty cycle close to 100%, and up to 20 times higher with special extended acquisition modes.
View Article and Find Full Text PDFPixelated LGADs have been established as the baseline technology for timing detectors for the High Granularity Timing Detector (HGTD) and the Endcap Timing Layer (ETL) of the ATLAS and CMS experiments, respectively. The drawback of segmenting an LGAD is the non-gain area present between pixels and the consequent reduction in the fill factor. To overcome this issue, the inverse LGAD (iLGAD) technology has been proposed by IMB-CNM to enhance the fill factor and provide excellent tracking capabilities.
View Article and Find Full Text PDFChromium compensated GaAs or GaAs:Cr sensors provided by the Tomsk State University (Russia) were characterized using the low noise, charge integrating readout chip JUNGFRAU with a pixel pitch of 75 × 75 µm regarding its application as an X-ray detector at synchrotrons sources or FELs. Sensor properties such as dark current, resistivity, noise performance, spectral resolution capability and charge transport properties were measured and compared with results from a previous batch of GaAs:Cr sensors which were produced from wafers obtained from a different supplier. The properties of the sample from the later batch of sensors from 2017 show a resistivity of 1.
View Article and Find Full Text PDFRecent advances in segmented low-gain avalanche detectors (LGADs) make them promising for the position-sensitive detection of low-energy X-ray photons thanks to their internal gain. LGAD microstrip sensors fabricated by Fondazione Bruno Kessler have been investigated using X-rays with both charge-integrating and single-photon-counting readout chips developed at the Paul Scherrer Institut. In this work it is shown that the charge multiplication occurring in the sensor allows the detection of X-rays with improved signal-to-noise ratio in comparison with standard silicon sensors.
View Article and Find Full Text PDFJ Synchrotron Radiat
September 2014
Although beamline instrumentation is by nature driven by science, some recent examples serve as reminders that new technologies also enable new science. Indeed, exploiting the full scientific potential of forthcoming new storage rings with unprecedented source characteristics will, in many cases, require the development and implementation of novel instrumentation. In comparison with present synchrotron radiation facilities, the majority of beamlines should reap immediate performance benefits from the improved source emittance, principally through increased flux and/or horizontal beam size reduction at the sample.
View Article and Find Full Text PDFPhys Rev E Stat Nonlin Soft Matter Phys
July 2013
This Brief Report studies the linear stability of a thermoconvective problem in an annular domain for relatively low (~1) Prandtl (viscosity effects) and Biot (heat transfer) numbers. The four possible patterns for the instabilities, namely, hydrothermal waves of first and second class, longitudinal rolls, and corotating rolls, are present in a small region of the Biot-Prandtl plane. This region can be split in four zones, depending on the sort of instability found.
View Article and Find Full Text PDFThe demand for access to macromolecular crystallography synchrotron beam time continues to increase. To meet this demand the ESRF has constructed a dual station beamline using a canted undulator system as the X-ray source. The first phase of the beamline to be constructed is ID23-1, a tunable MAD-capable station with a mini-focus X-ray beam.