Publications by authors named "P Van Malderen"

Objective: Hyperphosphatemia leads to increased risk of death in maintenance hemodialysis patients (MHD). This study investigated phosphorus (P) removal, P reduction rate (PRR), and P rebound, comparing on-line, high-volume hemodiafiltration in postdilution (HDF) and high-flux hemodialysis (HD) in a setting of an equal amount of produced dialysate solution in both modalities.

Methods: A total of 22 MHD patients, treated with regular 3 x 4 hours HDF weekly, were randomly dialyzed with one 4-hour session of HDF and of HD.

View Article and Find Full Text PDF

Background: The accumulation of beta2-microglobulin (beta2-M) in long-term dialysis patients may lead to dialysis amyloidosis. In this respect, the removal with different modes of on-line haemodiafiltration (HDF) of beta2-M was studied. Long-term clinical observations in patients with more than 10 years of dialysis, treated mainly with biocompatible and highly permeable membranes and in the last years with on-line HDF are also reported.

View Article and Find Full Text PDF

Various renal replacement therapies have been used for the treatment of acute renal failure in critically ill patients in the last decade. Due to the slower rate of solute and fluid removal, the continuous renal replacement therapies are generally better tolerated than conventional therapy. There is no consensus whether different treatment strategies effect the outcome of critically ill patients and no clear definition of adequacy of renal support in the severely ill patient.

View Article and Find Full Text PDF

Unlabelled: Eight chronic, anuric hemodialysis patients were randomly treated with a high-flux polysulphone dialyzer (F80), using 6 different modes: conventional bicarbonate hemodialysis (HD), hemodiafiltration (HDF) with a replacement solution at 40, 60, 80 or 100 ml/min in postdilution and 80 ml/min in predilution. The differences in beta 2-microglobulin (beta 2M) reduction ratio and clearance were evaluated statistically by analysis of variance (ANOVA). Both studies revealed no significant difference between HD and HDF40 in postdilution, but an increasing significant difference from HDF60 to HDF100 in postdilution and with HDF80 in predilution.

View Article and Find Full Text PDF

Since 1973, 41 autogenous saphenous vein (ASV) fistulae in the arm or the leg have been constructed in 30 chronic haemodialysis patients. The mean patency rate for the arm fistulae was 36.8 months and 21.