Background: The purpose was to assess the impact of irradiation technique type and beam energy on the mixed radiation field around the medical linear accelerator (linac) in terms of radiation quality and related radiation protection quantities.
Materials And Methods: Seven radiotherapeutic plans with Alderson-Rando anthropomorphic phantom [different techniques: conventional three-dimensional conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT) and intensity modulated arc therapy (IMAT), different beams: 6 MV or 18 MV, and their arrangements) were prepared for the case of prostate malignancy. Recombination chambers REM-2 and GW2 were positioned on the treatment couch 100 cm from the beam axis at the height of the isocentre.
Dosimetry based on gas detectors operating in the recombination and saturation region provides unique research opportunities but requires high-quality electrometers with a measuring range below 1 pA (10 A). The standard approach in electrometry is to strive to increase the accuracy and precision of the measurement, ignoring the importance of its duration. The article presents an algorithm for the measurement of low current values (from 100 fA) that allows both a fast measurement (with a step of 2.
View Article and Find Full Text PDFIn this study, the influence of additional 10B4C polarizing electrodes coating on KW-1 multisignal ionization chamber performance was investigated. Using the FLUKA Monte Carlo code energy deposition, neutron fluence and neutron track-length distributions were simulated. Further calculations allow us to obtain response functions for monoenergetic neutron beams in the energy range from 1 meV to 30 MeV.
View Article and Find Full Text PDFIn the study, the passive multi-layer neutron spectrometer, based on thermoluminescence detectors, was tested in a calibration laboratory with 239Pu-Be and 252Cf isotopic sources. MCNP code was used for the calculation of the response functions for the neutron energy range from 1 meV to 100 MeV. It was also utilised for initial guess spectra calculations.
View Article and Find Full Text PDFBackground: The inadvertent detachment of stent retrievers during mechanical thrombectomy is an extremely rare but feared complication associated with poor clinical outcomes. We discuss management considerations after an unexpected disconnection of the pRESET stent retriever during mechanical thrombectomy, based on clinical experience and mechanical and phantom studies.
Methods: We present a clinical course of rare accidents of stent-retriever separation inside an intracranial vessel that occurred in patients in a comprehensive stroke centre between 2018 and 2020.