Publications by authors named "P Trueb"

The aim of this study is to propose diagnostic reference levels (DRLs) values for mammography in Switzerland. For the data collection, a survey was conducted among a sufficient number of centres, including five University hospitals, several cantonal hospitals, and large private clinics, covering all linguistic regions of Switzerland to be representative of the clinical practice. The data gathered contained the mean glandular dose (MGD), the compressed breast thickness (CBT), the mammography model and the examination parameters for each acquisition.

View Article and Find Full Text PDF

Purpose: To assess whether two-point Dixon (TPD) MRI, true fast imaging with steady-state free precession (TRUFI) MRI and non-contrast-enhanced CT (NECT) can accurately measure muscle fat fraction (FF) in the autochthonous back muscles (AM) and the psoas muscle (PM) compared to multi-point Dixon (MPD) MRI.

Method: 29 oncological patients who received MRI including MPD, TPD and NECT imaging in a period of three months were analyzed retrospectively. A sub-cohort of 16 patients additionally underwent TRUFI MRI and were included in a sub-analysis.

View Article and Find Full Text PDF

Nationwide surveys on radiation dose to the population from medical imaging are recommended in order to follow trends in population exposure. The goal of the 2018 survey was to investigate the current exposure. The invoice coding information was collected in five university hospitals and large clinics.

View Article and Find Full Text PDF

Purpose: Definition of new national diagnostic reference levels (DRLs) for volume computed tomography dose index (CTDI) and dose length product (DLP) for neuro-paediatric CT examinations depending on the medical indication.

Methods: Paediatric cranial CT data sets acquired between January 2013 and December 2016 were retrospectively collected between July 2016 and March 2017 from eight of the largest university and cantonal hospitals that perform most of the neuro-paediatric CTs in Switzerland. A consensus review of CTDI and DLP was undertaken for three defined anatomical regions: brain, facial bone, and petrous bone, each with and without contrast medium application.

View Article and Find Full Text PDF

Purpose: Hybrid Photon Counting (HPC) detectors profoundly improved x-ray diffraction experiments at third generation synchrotron facilities. Enabling the simultaneous measurement of x-ray intensities in multiple energy bins, they also have many potential applications in the field of medical imaging. A prerequisite for this is a clean spectral response.

View Article and Find Full Text PDF