Publications by authors named "P Schury"

The new isotope ^{241}U was synthesized and systematic atomic mass measurements of nineteen neutron-rich Pa-Pu isotopes were performed in the multinucleon transfer reactions of the ^{238}U+^{198}Pt system at the KISS facility. The present experimental results demonstrate the crucial role of the multinucleon transfer reactions for accessing unexplored neutron-rich actinide isotopes toward the N=152 shell gap in this region of nuclides.

View Article and Find Full Text PDF

The atomic masses of ^{55}Sc, ^{56,58}Ti, and ^{56-59}V have been determined using the high-precision multireflection time-of-flight technique. The radioisotopes have been produced at RIKEN's Radioactive Isotope Beam Factory (RIBF) and delivered to the novel designed gas cell and multireflection system, which has been recently commissioned downstream of the ZeroDegree spectrometer following the BigRIPS separator. For ^{56,58}Ti and ^{56-59}V, the mass uncertainties have been reduced down to the order of 10 keV, shedding new light on the N=34 shell effect in Ti and V isotopes by the first high-precision mass measurements of the critical species ^{58}Ti and ^{59}V.

View Article and Find Full Text PDF

Mass-separated ^{187}Ta_{114} in a high-spin isomeric state has been produced for the first time by multinucleon transfer reactions, employing an argon gas-stopping cell and laser ionization. Internal γ rays revealed a T_{1/2}=7.3±0.

View Article and Find Full Text PDF

A procedure is introduced to extract the time-of-flight probability density distribution for ions of one type using an accumulated ion peak as a template for use in the fitting of time-of-flight peaks of co-accumulated ions. We demonstrate the use of logarithmic splines and discuss the statistical criteria for the selection of the spline smoothing parameter to obtain a smooth function for approximating such an ion peak. Furthermore, a "Bootstrap" method is proposed to determine the uncertainty of the fitted time-of-flight values, which is calculated using the extracted peak shape via a repeated statistical experiment.

View Article and Find Full Text PDF

Achieving the highest possible mass resolving power in a multireflection time-of-flight mass spectrometer requires very high-stability power supplies. To this end, we have developed a programmable high-voltage power supply that can achieve long-term stability in the order of parts-per-million. Herein, we present the design of a stable high-voltage system and bench-top stability measurements up to 1 kV; a stabilization technique can, in principle, be applied up to 15 kV or more.

View Article and Find Full Text PDF