The annual occupational doses for workers at the Ghana Research Reactor-1 facility were assessed for the period 2018-2021. The dose records of monitored staff were retrieved and analysis done for dose distribution and collective effective doses. Thermoluminiscent dosimeters were used to monitor the occupational exposures.

View Article and Find Full Text PDF

This study aimed at assessing patient's peak skin doses (PSD) during fluoroscopy cardiac procedures and proposed a look up table to enhance patient's dose management. Perspex phantom and thermoluminescent dosemeters (TLD) were irradiated for different dose levels with X-ray equipment (Philips Azurion 7). It was found that PSD measures were higher than the kerma at the interventional reference point [K (IRP)] reported with factors 1.

View Article and Find Full Text PDF

Analyses of the results of calibration of survey meters carried out at the Secondary Standards Dosimetry Laboratory (SSDL) in Ghana over a period of 4 y (2008-2011) are reported. The calibration factors (CFs) of the set of survey meters indicated that ∼91.04 % were within the acceptable limit of ± 20.

View Article and Find Full Text PDF

Radiation exposure of workers in Ghana have been estimated on the basis of personal dose records of the occupationally exposed in medical, industrial and research/teaching practices for the period 2008-09. The estimated effective doses for 2008 are 0.400, 0.