Appl Radiat Isot
September 2012
The national traceability chain for (131)I activity measurements performed in nuclear medicine in Cuba is described. At the highest (primary) level, liquid scintillation counting employing the CIEMAT/NIST method is used; at the secondary level, a secondary standard radionuclide calibrator is utilized that allows for a quick and simple transference of the measurement unit to the tertiary level of end-users' instruments. The equivalence of Cuban standards and the assessment of measurement uncertainties at the end-user level are determined through the results of measurement comparisons.
View Article and Find Full Text PDFRadioactivity found in wild food products has assumed greater importance when assessing the total exposure of the population. For this reason, IRMM has been developing a reference material for the activity concentration of three radionuclides in bilberry samples. In order to characterise this new material, a CCRI(II) supplementary comparison was organised.
View Article and Find Full Text PDFA generally applicable protocol for organizing comparisons among nuclear medicine clinics created within the IAEA project CRP E2.10.05 was tested in Brazil, Cuba, Czech Republic, India, Iran, Republic of Korea, Romania and Turkey in 2007.
View Article and Find Full Text PDFAppl Radiat Isot
March 2008
The traceability of activity measurements performed during the development phase of the radiopharmaceutical and in its clinical application is essential for establishing the comparability of clinical results reported in the nuclear medicine field. This paper presents and discusses the evaluation over time of the quality of activity measurement results obtained in Cuban nuclear medicine, on the basis of statistical samples taken during the radionuclide calibrator comparison program. An attempt is also made to evaluate the role played by such comparisons in quality measurement improvement in nuclear medicine, on the basis of results obtained in a number of countries and published by several authors over a period of time.
View Article and Find Full Text PDFThis paper describes the results obtained using a simulated test for administration of activity in nuclear medicine between 2002 and 2004. Measurements in the radionuclide calibrator are made during the different stages of the procedure. The test attempts to obtain supplementary information on the quality of the measurement, with the aim of evaluating in a more complete way the accuracy of the administered activity value compared with the prescribed one.