Publications by authors named "P Mouroulis"

Article Synopsis
  • - The Mapping Imaging Spectrometer for Europa (MISE) is an infrared instrument on NASA's Europa Clipper mission, aimed at understanding the composition and habitability of Europa's ocean and its icy surface.
  • - MISE will capture data from 0.8 to 5 μm with high spatial (25 m per pixel) and spectral resolution, helping identify critical components such as water ice, salts, acids, and organics on Europa's surface.
  • - This instrument, along with other Europa Clipper payloads, will enhance our knowledge of Europa's geological processes and surface structure, as detailed in the accompanying paper describing MISE's science goals, design, operations, and expected data products.
View Article and Find Full Text PDF

The design, characteristics, and first test flight results are described of the Portable Remote Imaging Spectrometer, an airborne sensor specifically designed to address the challenges of coastal ocean remote sensing. The sensor incorporates several technologies that are demonstrated for the first time, to the best of our knowledge, in a working system in order to achieve a high performance level in terms of uniformity, signal-to-noise ratio, low polarization sensitivity, low stray light, and high spatial resolution. The instrument covers the 350-1050 nm spectral range with a 2.

View Article and Find Full Text PDF

We have collected reflectance spectra of various unprocessed rock samples in the 450-1,650 nm wavelength range with a spatial resolution of 60 and 120 microm (diameter) and using three illumination modes. Spectra taken in diffuse reflectance (dark field) mode are comparable to those obtained from macroscopic measurements and can provide the basis for mineral detection at that spatial scale. The spectral discrimination of the dark field mode is demonstrated to be consistent with the spatial resolution of the microscope for the samples examined.

View Article and Find Full Text PDF

The introduction of spherical aberration in a lens design can be used to extend the depth of field while preserving resolution up to half the maximum diffraction-limited spatial frequency. Two low-power microscope objectives are shown that achieve an extension of +/- 0.88 lambda in terms of wavefront error, which is shown to be comparable to alternative techniques but without the use of special phase elements.

View Article and Find Full Text PDF

We present an optical design for an airborne imaging spectrometer that addresses the unique constraints imposed by imaging the coastal ocean region. A fast (F/1.8) wide field system (36 degrees) with minimum polarization dependence and high response uniformity is required, that covers the spectral range 350-1050 nm with 3 nm sampling.

View Article and Find Full Text PDF