An original sub-surface, high spatial resolution tomographic technique based on scanning microwave microscopy (SMM) is used to visualize in-depth materials with different chemical compositions. A significant phase difference in SMM between aluminum and chromium buried patterns has been observed. Moreover this technique was used to characterize a solid solution of a light chemical element (oxygen) in a metal lattice (zirconium).
View Article and Find Full Text PDFThe effect of the nature of the working electrode used in amperometric gas sensors on the performance criteria of sensitivity, detection limit, gas flow rate and humidity dependence was evaluated. The arrangement based on metallized ion-exchange membranes (Nafion) was compared with gas-diffusion electrodes based on porous poly(tetrafluoroethylene) (PTFE) with metallic electrodes deposited on the rear side. Two representative analyte gases were chosen: SO2, which has fast reaction kinetics, and NO, which has slow reaction kinetics.
View Article and Find Full Text PDFThe sensing device used is based on a porous Pt electrode, which is supported on an ion-exchange membrane and directly exposed to the gas phase. Under acid conditions, ethylene oxide was found to be oxidized on the platinum oxide surface at +550 mV vs MSE, thus enabling its monitoring via the measurement of the associated current. A detection limit of 15 ppb was obtained, based on a signal-to-noise ratio of three, and a linear dynamic range was found up to 100 ppm.
View Article and Find Full Text PDFThe minimal epitope of an anti-Candida albicans mannan monoclonal antibody (MAb) EB-CA1, used to detect mannanemia in patient sera, was determined, MAb EB-CA1 exhibited reactivity with oligomannosides released from the mannan acid stable domain, converted into neoglycolipids (NGLs) and coated onto ELISA plates. Reactivity occurred with mannopentaose and higher oligomers, whereas mannotriose and mannotetraose were unreactive. MAb EB-CA1 binding to mannan acid stable mannopentaose NGL displayed a dose dependent and saturable specific reactivity curve whereas there was a complete absence of binding, even at high concentrations, with NGLs constructed from the beta-1,2-linked mannopentaose derived from the mannan acid labile fraction.
View Article and Find Full Text PDFClin Diagn Lab Immunol
March 1996
Elevated antibody levels against the yeast Saccharomyces cerevisiae have been reported in sera from patients with Crohn's disease and not with ulcerative colitis. The aim of the study was to identify the nature of the epitopes supporting this antibody response. Whole cells from different S.
View Article and Find Full Text PDF