Article Synopsis
  • The study aimed to compare the refractive outcomes of mechanical PRK (mPRK) and transepithelial PRK (tPRK) using the WaveLight Allegretto EX500 laser system in patients with astigmatism and myopia.
  • Conducted at the Federal University of Sao Paulo, Brazil, the prospective randomized study involved 151 eyes from 73 patients, ensuring minimal differences in pre-surgery refraction.
  • Results indicated that six months post-surgery, mPRK had better uncorrected distance visual acuity (UDVA) and spherical equivalent (SE) compared to tPRK, though both procedures showed similar safety profiles.
View Article and Find Full Text PDF

Purpose: To objectively demonstrate eyelid spasms relief in hemifacial spasm (HFS) patients using a smartphone and a custom-made software.

Methods: Nineteen patients with HFS had standardized videos recorded with a smartphone (iPhone 6S, Apple) camera before and 15 days after receiving onabotulinumtoxinA injections. Nineteen age-matched control subjects were also assessed.

View Article and Find Full Text PDF

Purpose: To determine the absorbance coefficient of the thin porcine cornea to ultraviolet-A radiation (365 nm) submitted for crosslinking.

Methods: This in vitro, benchtop experiment using cadaver tissue study analyzed 12 porcine corneal lamellas, which were obtained using a microkeratome after mechanical de-epithelization and separated into three thickness groups: 180, 300, and 360 μm. The corneal thickness values were measured by anterior-segment optical coherence tomography.

View Article and Find Full Text PDF

Background: Artificial intelligence (AI) deals with development of algorithms that seek to perceive one's environment and perform actions that maximize one's chance of successfully reaching one's predetermined goals.

Objective: To provide an overview of the basic principles of AI and its main studies in the fields of glaucoma, retinopathy of prematurity, age-related macular degeneration and diabetic retinopathy. From this perspective, the limitations and potential challenges that have accompanied the implementation and development of this new technology within ophthalmology are presented.

View Article and Find Full Text PDF

Purpose: To evaluate the surgical technique, clinical performance, and biocompatibility of a novel keratoprosthesis (KPro) named KPro of Brazil (KoBra) in an alkali-burned rabbit model.

Methods: Two-piece three-dimensional-printed titanium powder and polymethyl methacrylate KPros were implanted into 14 alkali-burned corneas of 14 rabbits using an autologous full-thickness corneal graft as the KPro carrier. Rabbits were examined weekly for 12 months to evaluate retention and postoperative complications.

View Article and Find Full Text PDF