Publications by authors named "P J Zimetbaum"

Background: Use of pulmonary vein isolation (PVI) to treat atrial fibrillation continues to increase. Despite great interest in leveraging administrative data for real-world analyses, contemporary procedural codes for identifying PVI have not been evaluated.

Methods And Results: In this observational retrospective cohort study, inpatient PVIs were identified among US Medicare fee-for-service beneficiaries using Current Procedural Terminology (CPT) code 93656 in Carrier Line Files.

View Article and Find Full Text PDF

Background: The current standard of practice for cremating patients with cardiac implantable electronic devices (CIEDs) is surgical explantation before cremation to mitigate the risk of device explosion. This surgery may conflict with patient or family beliefs, whereas cremation of CIEDs may create occupational hazards.

Objective: This study sought to establish an ex vivo model for screening CIED behavior during cremation.

View Article and Find Full Text PDF

Background: Multiple studies continue to evaluate the use of intracardiac echocardiography (ICE) and transesophageal echocardiography (TEE) for guiding left atrial appendage occlusion (LAAO).

Objective: The purpose of this study was to conduct an updated meta-analysis comparing the effectiveness and safety outcomes of both imaging modalities.

Methods: PubMed, Cochrane, and Embase were searched for studies comparing ICE vs TEE to guide LAAO.

View Article and Find Full Text PDF

With the expanding use of cardiac implantable electronic device (CIED) therapy, intravascular device infections are becoming more common. In the case of transvenous implantable cardioverter-defibrillator (ICD) infections requiring extraction for bacterial clearance, there remains no standard method to deliver temporary ICD therapy following device removal. We present a case of persistent bacteremia complicated by monomorphic ventricular tachycardia (VT) electrical storm where biventricular ICD system extraction was performed and a temporary transvenous dual-coil lead with an externalized ICD generator was used to treat VT episodes prior to the re-implantation of a new permanent system.

View Article and Find Full Text PDF

Background: Early coronary occlusion detection by portable personal device with limited number of electrocardiographic (ECG) leads might shorten symptom-to-balloon time in acute coronary syndromes.

Objectives: The purpose of this study was to compare the accuracy of coronary occlusion detection using vectorcardgiographic analysis of a near-orthogonal 3-lead ECG configuration suitable for credit card-size personal device integration with automated and human 12 lead ECG interpretation.

Methods: The 12-lead ECGs with 3 additional leads ("abc") using 2 arm and 2 left parasternal electrodes were recorded in 66 patients undergoing percutaneous coronary intervention prior to ("baseline", n = 66), immediately before ("preinflation", n = 66), and after 90-second balloon coronary occlusion ("inflation", n = 120).

View Article and Find Full Text PDF