Publications by authors named "P Helevirta"

Background And Aims: Cancellous bone fractures and arthrodeses have been treated successfully with bioabsorbable polyglycolide and poly-L-lactide implants. In this study bioabsorbable poly-L-lactide lag screws and metallic screws were compared in the fixation of subcapital femoral neck fractures.

Patients And Methods: Forty patients with femoral neck fractures were treated by internal fixation using three bioabsorbable self-reinforced poly-L-lactide (SR-PLLA) lag screws of 6.

View Article and Find Full Text PDF

In this article, the design and properties of a new bioabsorbable suture anchor (SmartAnchor(trade mark)) are described and its properties are compared with those of some commercial anchors. Two comparative experiments were carried out in order to measure (1) the breaking force of suture/anchor attachment for SmartAnchor, MitekGII, and for Ogden anchors; and (2) the fixation force of the following anchors and tacks: SmartAnchor, MitekGII, BankartTack, and Suretac. The average suture/anchor attachment breaking force of SmartAnchor (204, 9 N) was 32% higher in comparison to MitekGII (155, 6 N) and 84% higher in comparison to the Ogden anchor (111, 4).

View Article and Find Full Text PDF

In a preliminary study, 24 patients with rupture of the anterior cruciate ligament (ACL) were operated on using implants made of self-reinforced poly-l-lactide (SR-PLLA). The operation method was outside-in bone-tendon-bone reconstruction. In 10 patients the fixation was made with an SR-PLLA screw with a diameter of 6.

View Article and Find Full Text PDF

The biocompatibility and degradation of self-reinforced poly-L-lactide (SR-PLLA) and polyglycolide (SR-PGA) miniscrews, vs titanium miniscrews, was studied in frontal bone osteotomies in 20 lambs, where they were used for plate fixation. At follow-up at 4, 6, 12, 26, 52 and 104 weeks, no clinical foreign body reaction, infection or other complications had occurred. Histologically, PGA material was hydrolyzed and fragmented at 4-6 weeks and was resorbed by 12 weeks, whereas the SR-PLLA miniscrews retained their integrity and holding power for 26 weeks and were mostly resorbed at 2 years.

View Article and Find Full Text PDF

The effect of the manufacturing method on the strength retention of self-reinforced poly-L-lactide (SR-PLLA) screws was studied in vitro and in vivo from 3 up to at least 15 weeks. SR-PLLA screws were manufactured from axially oriented SR-PLLA billets by the conventional compression moulding process and an in-house developed machine cutting technique. New machined SR-PLLA screws (thread diameters 4.

View Article and Find Full Text PDF