Background: With the Society of Gastrointestinal and Endoscopic Surgeons supervision, the Safe Cholecystectomy Task Force (SAFE CHOLE) was translated into French by the the Federation of Visceral and Digestive Surgery (FCVD) and adopted to run on its national e-learning platform for surgical continuing medical education (CME). The objective of this study was to assess the impact of the SAFE CHOLE (SF) program on the knowledge and practice of French surgeons performing cholecystectomy and participating in the FCVD lead CME activity.
Methods: To obtain CME certification, each participant must fill out three FCVD validated questionnaires regarding (1) the participants' routine practice for cholecystectomy, (2) the participants' knowledge and practice after successful completion of the program, and (3) the educational value of the SC program.
We analyzed the underlying principles of an unmodulated very-low-voltage (VLV) mode, designated as "soft coagulation" in hemostasis, and demonstrate its clinical applications. . While the advantage of the VLV mode has been reported across surgical specialties, the basic principle has not been well described and remains ambiguous.
View Article and Find Full Text PDFIntroduction: Healthcare consumers seeking accurate information about where to find quality surgical care face a confusing constellation of rating systems that lack transparency or consistency of opinion. For example, a 2016 report in Health Affairs demonstrated that no hospital was rated as a high performer by all four prominent national ratings systems: Consumer Reports, Leapfrog, Healthgrades and U.S.
View Article and Find Full Text PDFBackground: The growth of laparoscopic surgery has increased the use of laparoscopic electrosurgical devices based on radiofrequency current. Despite an improvement in most post-operative outcomes, the use of these devices can be associated with inadvertent thermal or mechanical injuries, also called accidental punctures and lacerations (APLs). APLs can occur through either operator error or system error, including insulation failure or capacitive coupling resulting in stray energy burns.
View Article and Find Full Text PDFBackground: Despite an early radical reoperation, recurrence and poor survival are observed in up to 40% of patients with an incidentally discovered gallbladder carcinoma (I-GBC) after undergoing a laparoscopic cholecystectomy (LC). This study seeks to identify prognostic factors after re-I-GBC resection.
Methods: A retrospective review of a prospectively maintained patient database with patients who were undergoing resection for I-GBC from January 1995 to March 2017 was performed.