Purpose: The patchy anatomical distribution of atherosclerosis has been attributed to variation in haemodynamic wall shear stress (WSS). The consensus is that low WSS and a high Oscillatory Shear Index (OSI) trigger the disease. We found that atherosclerosis at aortic branch sites correlates threefold better with transverse WSS (transWSS), a metric which quantifies multidirectional near-wall flow.
View Article and Find Full Text PDFUltrasound imaging is a valuable clinical tool. It is commonly achieved using the delay and sum beamformer algorithm, which takes the signals received by an array of sensors and generates an image estimating the spatial distribution of the signal sources. This algorithm, while computationally efficient, has limited resolution and suffers from high side lobes.
View Article and Find Full Text PDFObjective: Super-resolution ultrasound (SRUS) imaging through localizing and tracking microbubbles, also known as ultrasound localization microscopy (ULM), can produce sub-diffraction resolution images of micro-vessels. We have recently demonstrated 3-D selective SRUS with a matrix array and phase change contrast agents (PCCAs). However, this method is limited to a small field of view (FOV) and by the complex hardware required.
View Article and Find Full Text PDFAm J Physiol Heart Circ Physiol
July 2024
This study investigated the sensitivity and specificity of identifying heart failure with reduced ejection fraction (HFrEF) from measurements of the intensity and timing of arterial pulse waves. Previously validated methods combining ultrafast B-mode ultrasound, plane-wave transmission, singular value decomposition (SVD), and speckle tracking were used to characterize the compression and decompression ("S" and "D") waves occurring in early and late systole, respectively, in the carotid arteries of outpatients with left ventricular ejection fraction (LVEF) < 40%, determined by echocardiography, and signs and symptoms of heart failure, or with LVEF ≥ 50% and no signs or symptoms of heart failure. On average, the HFrEF group had significantly reduced S-wave intensity and energy, a greater interval between the R wave of the ECG and the S wave, a reduced interval between the S and D waves, and an increase in the S-wave shift (SWS), a novel metric that characterizes the shift in timing of the S wave away from the R wave of the ECG and toward the D wave (all < 0.
View Article and Find Full Text PDFObjective: This study aimed to realise 3-D super-resolution ultrasound imaging transcutaneously with a row-column array which has far fewer independent electronic channels and a wider field of view than typical fully addressed 2-D matrix arrays. The in vivo image quality of the row-column array is generally poor, particularly when imaging non-invasively. This study aimed to develop a suite of image formation and post-processing methods to improve image quality and demonstrate the feasibility of ultrasound localisation microscopy using a row-column array, transcutaneously on a rabbit model and in a human.
View Article and Find Full Text PDF