Publications by authors named "Ozen J"

Pediatric liver transplantation (PLT) has very good results at experienced transplant centers. However, there is still an ongoing discussion about inferior outcomes, especially in young infants. The aim of this retrospective study was to evaluate outcomes of infants compared to older recipients in a single center over 20 years.

View Article and Find Full Text PDF

The aim of this study was to present the use of retroauricular full-thickness skin grafts in vestibuloplasty surgeries for dental implant rehabilitation in vascularized fibula grafts. Two patients underwent mandibular reconstruction with vascularized fibula grafts due to mandibular gunshot injuries. Inadequate sulcus gaps secondary to mandibular soft tissue deficiencies were managed by full-thickness autologous skin grafts harvested from the retroauricular region.

View Article and Find Full Text PDF

The purpose of this study was to investigate the flexural strength of all-ceramics with varying core thicknesses submitted to aging. In-Ceram Alumina (IC), IPS e.max Press (EM) and Katana (K) (n=40), were selected.

View Article and Find Full Text PDF

Objectives: This study aimed to compare a number of new nano-composites capable of protecting the jaw from ionizing radiation.

Materials And Methods: Four different types of nano-powders [Ti, Zr (IV) oxide, Ag and Co] were mixed in a polymer matrix to create nano-composites with doping values of 8% in weight. Small-angle X-ray scattering (SAXS) analysis was performed using a HECUSSAXS system with 50 kV- 50 mA.

View Article and Find Full Text PDF

Objective: Clinicians should reserve all-ceramics with high translucency for clinical applications in which high-level esthetics are required. Furthermore, it is unclear whether a correlation exists between core thickness and color change. The aim of this study was to examine the effects of different core thicknesses and artificial aging on the color stability of three all-ceramic systems.

View Article and Find Full Text PDF

Background: Immediate loading of dental implants appears to be a successful option. Questions still remain whether annual failure rates (AFRs) as well as annual marginal bone-level changes are comparable with conventionally loaded implants.

Hypothesis: Immediately loaded implants (≤24 h after implantation) do not show different annual survival rates or peri-implant bone-level changes as compared to conventionally loaded implants (≥3 months after implantation).

View Article and Find Full Text PDF

This study was undertaken to evaluate the relation between bone quality and alterations of implant stability quotient values measured during the initial phase of healing. Nineteen patients treated with 106 implants were included in the current study. The mean bone density of the implant recipient area was measured using Simplant 11 software incorporated in the computerized tomography (CT) machine.

View Article and Find Full Text PDF

Objective: To investigate the effect of the accelerated aging process on the color stability of feldspathic ceramic treated with dual ion exchange, overglaze, polishing, and autoglaze surface treatments.

Method And Materials: A total of 40 disks (15 mm in diameter and 2 mm thick) of feldspathic ceramic were made in an A2 shade according to the manufacturer's recommendations. The samples were randomly divided into 4 groups: dual ion exchange, overglaze, polishing, and autoglaze.

View Article and Find Full Text PDF

The purpose of this study was to determine the effect of oral moisturizing agents, denture adhesives, and surface treatments on the retention of an acrylic resin test base dislodged from the maxillary alveolar ridges of xerostomic radiotherapy patients. Acrylic resin test bases prepared for 10 edentulous xerostomia patients were subjected to 8 surface treatment methods: method 1 = untreated dry surface; method 2 = use of Biotène oral moisturizer; method 3 = use of Protefix denture adhesive; method 4 = combination of Biotène and Protefix; method 5 = sandblasting of test bases; method 6 = use of Biotène on sandblasted surface; method 7 = use of Protefix on sandblasted surface; method 8 = combination of Protefix and Biotène on sandblasted surface. After each treatment, a tensile testing apparatus was used to dislodge the inserted test bases, and force values (N) were recorded.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to evaluate compressive and tensile stress values and patterns on implant-supported all-ceramic restorations applied in maxillary partially edentulous cases by utilizing the 3-dimensional (3-D) finite element stress analysis.

Method And Materials: Two different 3-D finite element designs representing a maxillary implant-supported fixed partial denture (from maxillary canine to second premolar) were constructed with 3 different core materials (Inceram-Zirconia, IPS 2 disilicate glass-ceramic, cobalt-chromium). In the first design, the cross-sectional connector areas of the dentures were constructed to be 3.

View Article and Find Full Text PDF

This study aimed to compare the effect of precementation desensitizing laser treatment and conventional desensitizing agents on crown retention. Crowns were fabricated for 50 molar teeth, and specimens were assigned to 5 groups based on treatment method: untreated control group (CON), laser group (LAS), sodium fluoride group (FLU), Oxagel oxalate group (OXA), and Gluma primer group (GLU). All crowns were luted with glass-ionomer cement.

View Article and Find Full Text PDF

Purpose: To determine the optimal thickness of protective oral radiation shields composed of an acrylic resin stent and a lead shield, which are used in head and neck radiotherapy to minimize undesired normal tissue radiomorbidity.

Materials And Methods: Intraoral acrylic resin stents and lead shields of different thicknesses were inserted into a specially designed human mandible phantom with thermoluminescent lithium fluoride dosimeter chips (TLD-100) placed on the buccal and lingual sites and exposed to irradiation of different energies. Fifty-cGy irradiation was performed and TLD-100 dose measurements were obtained for each irradiation type, acrylic resin stent thickness, and lead shield thickness.

View Article and Find Full Text PDF

A self-inflicted gunshot maxillofacial defect was restored with dental implants and various attachments. Following mandibular surgical reconstruction, a fixed full-arch implant-supported prosthesis was fabricated. The maxillary defect was restored with an obturator retained with bar-clip and ball attachments.

View Article and Find Full Text PDF

Acrylic resin dentures may have cytotoxic effects on oral soft tissues. However, there is sparse data about the cytotoxic effect of fibre-reinforced acrylic resin denture base materials. The purpose of this in vitro study was to determine the effect of two fibre impregnation methods on the cytotoxicity of a glass and carbon fibre-reinforced heat-polymerized acrylic resin denture base material on oral epithelial cells and fibroblasts.

View Article and Find Full Text PDF

Purpose: Patterns of von Mises stress values surrounding implants supporting fixed prostheses in the posterior edentulous maxilla were evaluated using 3-dimensional finite element analysis.

Materials And Methods: Implants were placed in maxillary bone in 2 different configurations. In the first configuration, implants were placed in the first premolar, second premolar, and second molar regions; in the second configuration, implants were placed in the second premolar and second molar regions, and a mesial cantilever was extended to the space of the first premolar tooth on the superstructure.

View Article and Find Full Text PDF

Purpose: The purpose of this in vitro study was to demonstrate the dentinal tubule-occluding effect of desensitizing laser treatment on dentin surfaces using environmental scanning electron microscopy (E-SEM).

Materials And Methods: Ground dentin surfaces were divided into 5 areas. Each area received a different mode of laser irradiation (low potency [LP] versus high potency [HP] and short time [ST] versus long time [LT]).

View Article and Find Full Text PDF

Objectives: In this study, quantification of backscatter doses between scattering titanium dental implant and the thermoluminescent dosimeter (TLD(100)) radiation detector at axial beam irradiation-angle range of 0-90 degrees in head and neck radiotherapy is done to evaluate irradiation angle dependency of dose enhancement contributing to osteoradionecrosis.

Methods: A cylindrical titanium dental implant with diameter of 4 mm and length of 9 mm was implanted into a specially-designed human mandible phantom with a TLD100 chip placed on the buccal site and irradiated with 6 MV X, 25 MV X and Co-60 gamma sources at 19 different irradiation angles.

Results: Dose enhancement on a buccal site of the titanium implant depends on the incident beam angle.

View Article and Find Full Text PDF

Purpose: This study evaluated the validity of the color selection results obtained from digital cameras.

Materials And Methods: Four observers matched the colors of 30 extracted maxillary incisors under daylight conditions. Two different digital cameras, with 1.

View Article and Find Full Text PDF

Little information is available on the immunological basis for side-effects of dental materials. The objective of this study is to evaluate effects of pure metals, dental alloys and ceramic on cell viability and interleukin-1 beta (IL-1beta) release in three-dimensional human gingival fibroblast cultures as an indicator of their biological performance in gingival tissues. The gingival fibroblast cultures were exposed to test specimens fabricated from nickel, iron, molybdenum, copper, indium, gold, Ni-Cr-Mo alloy (Remanium CS), Au-Pt-In alloy (Pontostar) and a dental ceramic (In-ceram).

View Article and Find Full Text PDF

Objective: The aim of the study was to examine the dose enhancement from scattered radiation at bone-dental implant interfaces during simulated head and neck radiotherapy.

Study Design: Four cylindrical titanium dental implants with 3 different sizes and lengths were implanted into a human mandible in 4 different positions. Ionization measurements for 6 MV X, 25 MV X, and Co-60 gamma rays were done.

View Article and Find Full Text PDF