Publications by authors named "Ozan O"

Purpose: The study aimed to determine the influence of implant angulation on the trueness of multi-unit implant impressions taken through different techniques and strategies.

Materials And Methods: As reference models, three partially edentulous mandibular models (Model 1: No angulation; Model 2: No angulation for #33, 15-degree distal angulation for #35 and #37; Model 3: No angulation for #33, 25-degree distal angulation for #35 and #37) were created by modifying the angulations of implant analogues. Using a lab scanner, these reference models were scanned.

View Article and Find Full Text PDF

Purpose: To study the influence of insertion depth and implant angulation on the 3D trueness of models obtained with different impression techniques.

Materials And Methods: Four different reference models (model 1: parallel, depth of 1.5 mm; model 2: parallel, depth of 4 mm; model 3: 20-degree angle, depth of 1.

View Article and Find Full Text PDF

Listeria monocytogenes is a ubiquitous opportunistic foodborne pathogen capable of survival in various adverse environmental conditions. Pathogenesis of L. monocytogenes is tightly controlled by a complex regulatory network of transcriptional regulators that are necessary for survival and adaptations to harsh environmental conditions both inside and outside host cells.

View Article and Find Full Text PDF

The long-term success of dental implants is greatly influenced by the use of appropriate materials while applying the "All-on-4" concept in the edentulous jaw. This study aims to evaluate the stress distribution in the "All-on-4" prosthesis across different material combinations using three-dimensional finite element analysis (FEA) and to evaluate which opposing arch material has destructive effects on which prosthetic material while offering certain recommendations to clinicians accordingly. Acrylic and ceramic-based hybrid prosthesis have been modelled on a rehabilitated maxilla using the "All-on-4" protocol.

View Article and Find Full Text PDF

Statement Of Problem: How material loss from sleeves and drills is affected when different guide sleeve materials and different sizes of implant drills are used for different regions of surgical guides is unclear.

Purpose: The purpose of this in vitro study was to compare the amount of material loss from different guide sleeves (zirconia and cobalt-chromium) and drills of different diameters during osteotomy preparation in different regions.

Material And Methods: Three tooth-supported surgical guides with sleeve holes positioned in the first premolar and second molar sites were prepared.

View Article and Find Full Text PDF

Background: Alveolar bone height in the posterior maxillary region is very important and critical for dental implant planning and placement.

Objectives: This study aimed to evaluate the anatomy of the maxillary sinus floor in relation to the alveolar crest and to determine variations in the vertical measurements between the maxillary sinus floor and the alveolar bone crest tip in the posterior edentulous maxilla with the use of cone beam computerized tomography.

Methods: This analysis enrolled 234 retrospectively selected patients (123 males with mean age 52.

View Article and Find Full Text PDF

Converting an acrylic resin removable complete prosthesis into a fixed implant-supported prosthesis to immediately load the implants can be a challenging procedure. Using acrylic resin to secure titanium interim copings intraorally may be a difficult task, and any process to facilitate this procedure may be advantageous for the clinician and the patient. This report describes a technique for facilitating the fabrication of an interim immediately loaded implant-supported fixed complete prosthesis.

View Article and Find Full Text PDF

Background: Patients with severely atrophied jaws can be challenging in implantology. The All-on-4 treatment concept eliminates advanced augmentation procedures in highly resorbed ridges by preserving the relevant anatomic structures. In addition, the inclination of the distal implants enables the placement of longer implants.

View Article and Find Full Text PDF

Background: There is no consensus in the literature regarding the impression procedures in the presence of multiple and angulated implants.

Methods: Three maxillary master models with 6 implants bilaterally positioned in anterior, premolar and molar regions were fabricated. In model 1, all implants were placed in parallel; in models 2 and 3, anterior implants were buccally inclined and posterior implants were distally inclined in 10- and 20-degrees, respectively.

View Article and Find Full Text PDF

BACKGROUND The aim of this study was to evaluate the precision of correlation between intraoral scanners and computer aided design (CAD) software programs used during scanning and designing phases of digital dentistry. In the present study, CAD software programs that accept data in Standard Tessellation Language (STL) and proprietary format have been evaluated and data loss has been examined in the scanned data. MATERIAL AND METHODS A single unit crown preparation was conducted for maxillary right first molar on a fully dentulous model.

View Article and Find Full Text PDF

Objective: To investigate the influence of surface treatments conducted in presintering and postsintering stages on flexural strength and optical properties of zirconia.

Materials And Methods: Specimens were milled from partially sintered zirconia blocks in different geometries and divided into three main groups as presintered, postsintered, and control groups. Test groups were further divided into three subgroups (n = 10) according to the surface treatments conducted (grinding, Er,Cr:YSGG laser irradiation, air-borne particle abrasion [APA]).

View Article and Find Full Text PDF

Background: Chronic kidney disease (CKD) is associated with an increased risk of adverse cardiovascular outcomes, in patients with coronary artery disease (CAD) undergoing percutaneous coronary intervention (PCI). However, most studies used bare-metal stents or first-generation drug-eluting stents, and less guideline-directed therapy to reduce cardiovascular risk was reported in CKD patients. This study investigates the impact of moderate-CKD on patients undergoing PCI in the current era.

View Article and Find Full Text PDF

Statement Of Problem: A nonpassive fit of implant-supported restorations can jeopardize the biological and mechanical success of the treatment. Data regarding the fit of different impression techniques for the all-on-4 protocol are limited.

Purpose: The purpose of this in vitro study was to digitally evaluate 4 different impression techniques used with the all-on-4 protocol, with distal multiunit analogs positioned in 4 different angulations.

View Article and Find Full Text PDF

Aims: The aim of this study was to compare the dimensional accuracy of four different implant impression techniques of a mandibular edentulous model with five parallel implants.

Materials And Methods: Five dental implants were placed in an edentulous mandibular model in parallel. A total of forty impressions were obtained using four different impression techniques.

View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate the effect of implant inclination and cantilever length on the stress distribution in mandibular cortical bone, implant, abutment, prosthetic framework, and prosthetic screw via three-dimensional (3D) finite element analysis (FEA).

Materials And Methods: Four different finite element models (0-0, 17-17, 30-30, 45-30) were designed according to the tilting angle (0, 17, 30, and 45 degrees) of the posterior implant and angle of multiunit abutments (0, 17, and 30 degrees). Screw-retained fixed prostheses with different cantilever lengths in accordance with implant inclination were modeled.

View Article and Find Full Text PDF

Anemic patients remain at increased risk of ischemic and bleeding events. Whether the effects of hemoglobin levels on thrombotic and bleeding risk are independent of platelet reactivity on clopidogrel, however, remains unknown. Patients from the Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents study were categorized by the presence of anemia at baseline, defined according the World Health Organization criteria.

View Article and Find Full Text PDF

Objectives: The aim of this study was to investigate the accuracy of 2 different impression techniques and 3 different impression materials in models simulating parallel and angulated implants.

Methods: Three master models simulating partial edentulous mandible with 2 implants at the sites of second premolars (parallel) and second molars with different angulations (parallel, 10° or 20° angulated) were fabricated. Two different impression techniques [splinted direct (D), indirect (I)] and 3 different monophase impression materials [polyether (PE), vinyl polysiloxane (VPS), vinyl polyether silicone (VPES)] were used for each master model and a total of 180 impressions were made (n=10).

View Article and Find Full Text PDF

Objective: The aim of this study was to compare the effects of erbium, chromium: yttrium, scandium, gallium, and garnet (Er,Cr:YSGG) laser application to different surface treatments on the micropush-out bond strengths between glass and quartz fiber posts and composite resin core material.

Background Data: Different types of lasers have been used as an alternative to airborne particle abrasion and other surface treatment methods to enhance the bond strength of dental materials. However, there is no study regarding the use of Er,Cr:YSGG laser as a surface treatment method for fiber posts in order to improve the bond strength.

View Article and Find Full Text PDF

Implant-supported overdentures with self-aligning attachment systems are preferred to improve the stability and retention of complete dentures. The positioning of the implant attachments is a very important aspect of two-implant overdentures in obtaining better stress distribution. Therefore, the objective of this study was to compare two different attachment systems in a two-implant overdenture by evaluating the stress distributions in peri-implant bone and stresses on the attachments with positioning at different height levels using the 3D FEA method.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to analyze the functional stresses around implants and supporting tissues placed in different combinations in the grafted and nongrafted atrophic posterior maxilla and to consider the acceptability of various fixed partial denture treatment options.

Materials And Methods: A computer model of the atrophic posterior maxilla was created from the computed tomography images of an actual patient. Three different treatment scenarios were modeled with partial denture restorations, grafted and nongrafted maxillary sinuses, and various implant inclinations.

View Article and Find Full Text PDF

Purpose: To compare the clinical success of a self-adhesive resin cement used in combination with different adhesive bonding systems with that of a conventional dual-cure resin cement.

Methods: The study was performed with 136 freshly extracted molars embedded in acrylic resin blocks and 136 IPS e.max Press discs.

View Article and Find Full Text PDF

Purpose: The aim of this study was to compare vertical and horizontal mandibular alveolar bone resorption by measuring bone morphological variation in Kennedy Class II removable partial denture (RPD) wearers and non-wearers using cone-beam computed tomography (CBCT).

Materials And Methods: In total, 124 sites in the CBCT scans of 62 (29 RPD non-wearers, 33 RPD wearers) Kennedy Class II patients were analyzed retrospectively. Three-dimensional representations of the mandible with superimposed cross-sectional slices were developed with the CBCT scans to evaluate the mandibular alveolar height and width by measuring distances between the mandibular canal, mylohyoid ridge, alveolar crest, and lower border of the mandible in four regions (eight sites) of Kennedy Class II non-wearers and wearers of RPDs.

View Article and Find Full Text PDF

Background: The aim of this study was to evaluate the correlation between the density of bone where implants were placed and the angular deviations that occurred between the virtually planned and actually placed implants using 2 different stereolithographic surgical guides.

Methods: The study population consisted of 54 patients who received 216 implants. Computed tomography machine was used for preoperative evaluation of the jawbone for implant therapy as well as determination of the bone density values (Hounsfield units [HU]) of the implantation site.

View Article and Find Full Text PDF

The success of implant-supported restorations depends on the treatment planning and the transfer of planning through the surgical field. Recently, new computer-aided design and manufacturing (CAD/CAM) techniques, such as stereolithographic (SLA) rapid prototyping, have been developed to fabricate surgical guides to improve the precision of implant placement. The objective of the present case is to introduce a recently developed SLA surgical guide system into the rehabilitation of a 62-year-old male patient with mandibular edentulism.

View Article and Find Full Text PDF

Numb chin syndrome, sometimes called numb lip syndrome, is an uncommon but well-recognized symptom in medical oncology. It may be a metastatic neurologic manifestation of malignancy, often with no clinically visible pathologic finding. The authors report a numb chin syndrome as a manifestation possible breast cancer metastasis around dental implants in a 69-year-old woman.

View Article and Find Full Text PDF