Spectrochim Acta A Mol Biomol Spectrosc
September 2017
We have recently reported infrared spectroscopy of human skin in vivo using quantum cascade laser excitation and photoacoustic or photothermal detection for non-invasive glucose measurement . Here, we analyze the IR light diffusely reflected from skin layers for spectral contributions of glucose. Excitation of human skin by an external cavity tunable quantum cascade laser in the spectral region from 1000 to 1245cm, where glucose exhibits a fingerprint absorption, yields reflectance spectra with some contributions from glucose molecules.
View Article and Find Full Text PDFWe have reported two methods to analyze glucose in the interstitial fluid of skin based on mid-infrared excitation with a tunable quantum cascade laser and photoacoustic or photothermal detection. These methods were evaluated for optimum skin locations to obtain reproducible glucose information. The lower part of the arm, the hypothenar, the tips of the index finger and the thumb were tested.
View Article and Find Full Text PDFAn infrared spectroscopic technique is described that employs a mid-IR broadband (980-1245 cm) tunable quantum cascade laser (QCL) to produce a pump beam, and a detection method based on photothermal deflection, enhanced by total internal reflection. The IR spectra thus obtained are depth-dependent by modulating the pump beam with different frequencies between 10 Hz and 500 Hz. A model system consisting of glucose and a polymer film is used to demonstrate the depth selectivity of this technique.
View Article and Find Full Text PDFThe application of a novel open, windowless cell for the photoacoustic infrared spectroscopy of human skin is described. This windowless cavity is tuned for optimum performance in the ultrasound range between 50 and 60 kHz. In combination with an external cavity tunable quantum cascade laser emitting in the range from ~1000 cm(-1) to 1245 cm(-1), this approach leads to high signal-to-noise-ratio (SNR) for mid-infrared spectra of human skin.
View Article and Find Full Text PDFThe noninvasive determination of glucose in the interstitial layer of the human skin by mid-infrared spectroscopy is reported. The sensitivity for this measurement was obtained by combining the high pulse energy from an external cavity quantum cascade laser (EC-QCL) tunable in the infrared glucose fingerprint region (1000-1220 cm(-1)) focused on the skin, with a detection of the absorbance process by photoacoustic spectroscopy in the ultrasound region performed by a gas cell coupled to the skin. This combination facilitates a quantitative measurement for concentrations of skin glucose in the range from <50 mg/dL to >300 mg/dL, which is the relevant range for the glucose monitoring in diabetes patients.
View Article and Find Full Text PDF