Purpose: Long-term ambulatory EEG recordings can improve the monitoring of absence epilepsy in children, but signal quality and increased review workload are a concern. We evaluated the feasibility of around-the-ears EEG arrays (cEEGrids) to capture 3-Hz short-lasting and ictal spike-and-wave discharges and assessed the performance of automated detection software in cEEGrids data. We compared patterns of bilateral synchronisation between short-lasting and ictal spike-and-wave discharges.
View Article and Find Full Text PDFThe diagnostic process for epilepsy can be lengthy and stressful, which may delay the start of treatment. The objective of this study was to determine the benefit of routine magnetoencephalography (MEG) with regard to diagnostic gain, compared to routine electroencephalography (EEG), EEG following sleep deprivation (EEGsd), and 24-hour EEG. In this prospective study, patients were included from two centres (Academic Centre for Epileptology Kempenhaeghe, Heeze and Elisabeth-Twee Steden Hospital, Tilburg) and MEG recording took place at a single centre (Amsterdam University Medical Centre, Vrije Universiteit Amsterdam) in The Netherlands.
View Article and Find Full Text PDFObjective: Our objective was to unravel the dynamics underlying spike-and-wave discharges (SWDs) characteristic for childhood absence epilepsy.
Methods: SWDs were recorded for a cohort of 28 children using magnetoencephalography. Non-linear association analyses and a graph theoretical metric of local connectedness (LoC) were utilized in a sliding window starting one s before till four s after ictal onset.
Purpose: To study possible detection of structural abnormalities on 7T MRI that were not detected on 3T MRI and estimate the added value of MEG-guidance. For abnormalities found, analysis of convergence between clinical, MEG and 7T MRI localization of suspected epileptogenic foci.
Methods: In adult patients with well-documented localization-related epilepsy in whom a previous 3T MRI did not demonstrate an epileptogenic lesion but MEG indicated a plausible epileptogenic focus, 7T MRI was performed.
Objective: The interictal epileptic discharges (IEDs) occurring in stereotactic EEG (SEEG) recordings are in general abundant compared to ictal discharges, but difficult to interpret due to complex underlying network interactions. A framework is developed to model these network interactions.
Methods: To identify the synchronized neuronal activity underlying the IEDs, the variation in correlation over time of the SEEG signals is related to the occurrence of IEDs using the general linear model.
Background: An accurate delineation of the optic radiation (OR) using diffusion MR tractography may reduce the risk of a visual field deficit after temporal lobe resection. However, tractography is prone to generate spurious streamlines, which deviate strongly from neighboring streamlines and hinder a reliable distance measurement between the temporal pole and the Meyer's loop (ML-TP distance).
New Method: Stability metrics are introduced for the automated removal of spurious streamlines near the Meyer's loop.
Objective: Subtle motion of an epileptic patient examined with co-registered EEG and functional MRI (EEG-fMRI) may often lead to spurious fMRI activation patterns when true epileptic spikes are contaminated with motion artefacts. In recent years, methods relying on reference signals for correcting these subtle movements in the EEG have emerged. In this study, the performance of two reference-based devices are compared to the template-based method with regard to their ability to remove movement-related artifacts in EEG measured during scanning.
View Article and Find Full Text PDFObjective: MEG and EEG after sleep deprivation (EEG-SD) are applied as diagnostic tools in the evaluation of patients with possible epilepsy. There is no gold standard to check whether the diagnosis based on these two modalities is correct. The best standard available is the long-term follow-up of patients.
View Article and Find Full Text PDFStructural brain networks constructed based on diffusion-weighted MRI (dMRI) have provided a systems perspective to explore the organization of the human brain. Some redundant and nonexistent fibers, however, are inevitably generated in whole brain tractography. We propose to add one critical step while constructing the networks to remove these fibers using the linear fascicle evaluation (LiFE) method, and study the differences between the networks with and without LiFE optimization.
View Article and Find Full Text PDFPurpose: Although absence epilepsy is considered to be a prototypic type of generalized epilepsy, it is still under debate whether generalized 3 Hz spike-and-wave discharges (SWDs) might have a cortical focal origin. Here it is investigated whether focal interictal epileptiform discharges (IEDs), which typically occur in the electro- (EEG) and magnetoencephalogram (MEG) in case of focal epilepsy, are present in the MEG of children with absence epilepsy. Next, the location of the sources of the IEDs is established, and it is investigated whether the location is concordant to the earlier established focal cortical regions involved in the generalized SWDs of these children.
View Article and Find Full Text PDFAnti-epileptic drugs (AEDs) have a global effect on the neurophysiology of the brain which is most likely reflected in functional brain activity recorded with EEG and fMRI. These effects may cause substantial inter-subject variability in studies where EEG correlated functional MRI (EEG-fMRI) is used to determine the epileptogenic zone in patients who are candidate for epilepsy surgery. In the present study the effects on resting state fMRI are quantified in conditions with AED administration and after withdrawal of AEDs.
View Article and Find Full Text PDFStructural brain networks based on diffusion MRI and tractography show robust attributes such as small-worldness, hierarchical modularity, and rich-club organization. However, there are large discrepancies in the reports about specific network measures. It is hypothesized that these discrepancies result from the influence of construction methodology.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
December 2015
A high density wireless electroencephalographic (EEG) platform has been designed. It is able to record up to 64 EEG channels with electrode to tissue impedance (ETI) monitoring. The analog front-end is based on two kinds of low power ASICs implementing the active electrodes and the amplifier.
View Article and Find Full Text PDFObjective: A method for automatic detection of epileptic seizures in long-term scalp-EEG recordings called EpiScan will be presented. EpiScan is used as alarm device to notify medical staff of epilepsy monitoring units (EMUs) in case of a seizure.
Methods: A prospective multi-center study was performed in three EMUs including 205 patients.
Spatial independent component analysis (ICA) is increasingly being used to extract resting-state networks from fMRI data. Previous studies showed that ICA also reveals independent components (ICs) related to the seizure onset zone. However, it is currently unknown how these epileptic ICs depend on the presence of interictal epileptic discharges (IEDs) in the EEG.
View Article and Find Full Text PDFDiffusion MRI and tractography allow for investigation of the architectural configuration of white matter in vivo, offering new avenues for applications like presurgical planning. Despite the promising outlook, there are many pitfalls that complicate its use for (clinical) application. Amongst these are inaccuracies in the geometry of the diffusion profiles on which tractography is based, and poor alignment with neighboring profiles.
View Article and Find Full Text PDFBackground: Diagnosing epilepsy is a lengthy and burdensome process for patients and their family. Although the need for a more patient-centered approach in clinical practice is widely acknowledged, empirical evidence regarding patient preferences for diagnostic modalities in epilepsy is missing. The objectives of this study were 1) to identify to what extent important attributes of diagnostic procedures in epilepsy affect preferences for a procedure, 2) to determine the relative importance of these attributes, and 3) to calculate overall utility scores for routine electroencephalography (EEG) and magnetoencephalography (MEG) recordings.
View Article and Find Full Text PDFEEG-correlated functional MRI (EEG-fMRI) visualizes brain regions associated with interictal epileptiform discharges (IEDs). This technique images the epileptiform network, including multifocal, superficial and deeply situated cortical areas. To understand the role of EEG-fMRI in presurgical evaluation, its results should be validated relative to a gold standard.
View Article and Find Full Text PDFCo-registered EEG and functional MRI (EEG/fMRI) is a potential clinical tool for planning invasive EEG in patients with epilepsy. In addition, the analysis of EEG/fMRI data provides a fundamental insight into the precise physiological meaning of both fMRI and EEG data. Routine application of EEG/fMRI for localization of epileptic sources is hampered by large artefacts in the EEG, caused by switching of scanner gradients and heartbeat effects.
View Article and Find Full Text PDFEEG-correlated functional MRI (EEG-fMRI) has been used to indicate brain regions associated with interictal epileptiform discharges (IEDs). This technique enables the delineation of the complete epileptiform network, including multifocal and deeply situated cortical areas. Before EEG-fMRI can be used as an additional diagnostic tool in the preoperative work-up, its added value should be assessed in relation to intracranial EEG recorded from depth electrodes (SEEG) or from the cortex (ECoG), currently the clinical standard.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2012
In this paper we show a proof of concept for novel automatic seizure onset zone detector. The proposed approach utilizes the Austrian Institute of Technology (AIT) seizure detection system EpiScan extended by a frequency domain source localization module. EpiScan was proven to detect rhythmic epileptoform seizure activity often seen during the early phase of epileptic seizures with reasonable high sensitivity and specificity.
View Article and Find Full Text PDFThe analysis of simultaneous EEG and fMRI data is generally based on the extraction of regressors of interest from the EEG, which are correlated to the fMRI data in a general linear model setting. In more advanced approaches, the spatial information of EEG is also exploited by assuming underlying dipole models. In this study, we present a semi automatic and efficient method to determine electrode positions from electrode gel artifacts, facilitating the integration of EEG and fMRI in future EEG/fMRI data models.
View Article and Find Full Text PDFTo describe the spatial and temporal profiles of connectivity networks and sources preceding generalized spike-and-wave discharges (SWDs) in human absence epilepsy. Nonlinear associations of MEG signals and cluster indices obtained within the framework of graph theory were determined, while source localization in the frequency domain was performed in the low frequency bands with dynamic imaging of coherent sources. The results were projected on a three-dimensional surface rendering of the brain using a semi-realistic head model and MRI images obtained for each of the five patients studied.
View Article and Find Full Text PDF