Publications by authors named "Osamu Nishizaki"

Purpose: A recent report by the American Association of Physicists in Medicine Task Group 75 and 180 provided imaging dose estimates for image-guided CyberKnife radiotherapy. However, to our knowledge, there have been no concrete demonstrations of imaging intervals that are directly linked to exposure dose. We hypothesized that setting a rational standard may be clearer through a balance of treatment accuracy and reducing imaging doses if the margin of the planned treatment volume is controlled through the imaging interval.

View Article and Find Full Text PDF

The purpose of this study was to evaluate the relationship between pressure on the occipital region and intrafraction motion using an individualized vacuum pillow and a thermoplastic mask for intracranial treatment. We calculated head displacement during treatment from 8811 image verifications in 59 patients and divided them into two groups according to the magnitude of the mean and standard deviation (SD) of the displacement in the 59 patients. Pressure was compared between the small (n = 29) and large (n = 30) displacement groups using Welch's t-test for the mean and SD of displacement.

View Article and Find Full Text PDF

This study developed a dedicated real-time monitoring system to detect intra-fractional head motion in intracranial radiotherapy using pressure sensors. The dedicated real-time monitoring system consists of pressure sensors with a thickness of 0.6 mm and a radius of 9.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to develop a new phantom to evaluate the positioning accuracy of patient immobilization systems.

Methods: The phantom was made of papers formed into a human shape, paper clay, and filling rigid polyester. Acrylonitrile butadiene styrene (ABS) pipes were inserted at anterior-posterior (A-P) and right-left (R-L) directions in the phantom to give static load by pulling ropes through the pipes.

View Article and Find Full Text PDF

A 70-year-old right-handed Japanese man who had undergone surgical resection for hepatocellular carcinoma (HCC) 2 years earlier was diagnosed with lung metastasis 3 months before consulting our hospital with a headache and visual field disturbance. Head computed tomography revealed a brain tumor with an intracerebral hemorrhage. Using (99m)Tc-PMT (pyridoxal-5-methly-triptophan) scintigraphy, we determined that the brain tumor was metastasis from the HCC and utilized the cyber-knife for treatment.

View Article and Find Full Text PDF

Purpose: In stereotactic conformal radiotherapy of the CyberKnife, multiple narrow beams from a cylindrical collimator are delivered to a planning target volume (PTV) without an isocenter by inverse planning. The influence of collimator size on stereotactic conformal radiotherapy was examined.

Materials And Methods: Five targets including two spherical targets (2.

View Article and Find Full Text PDF

Selective serotonin reuptake inhibitors (SSRI) are newly developed-antidepressants authorized in 1999 in Japan. We experienced a case of drug poisoning including fluvoxamine, one of SSRI. A comatose nineteen-year-old girl was transported to our ER in the morning on July 25, 2000.

View Article and Find Full Text PDF