Statement Of Problem: The accuracy of virtual interocclusal records has been evaluated, but clinical studies comparing the clinical output to the virtual design are lacking.

Purpose: The purpose of this clinical study was to evaluate the agreement between the virtual occlusal scheme designed by a computer-aided design and computer-aided manufacturing software program and the occlusal scheme obtained clinically on the definitive prosthesis assessed with articulating paper.

Material And Methods: The virtual occlusal scheme design of 20 single monolithic crowns and their adjacent teeth was obtained by using an intraoral scanning system in 17 participants.

View Article and Find Full Text PDF

A wide variety of titanium (Ti) alloy dental implant systems are available and as a result, choosing the correct system has become a challenge. Cleanliness of the dental implant surface affects osseointegration but surface cleanliness may be jeopardized during manufacturing. The purpose of this study was to assess the cleanliness of three implant systems.

View Article and Find Full Text PDF

Aim: To evaluate CAD/CAM milling vibrations related to zirconia disk design, framework, and location of digital crown nesting during zirconia soft milling.

Materials And Methods: In the present in vitro study, 25 round zirconia disks of 98 mm (R group) and 15 D-shaped zirconia disks of 71 mm (D group) were placed in a 5-axis CAD/CAM milling unit. The R group had 3 crown milling sites (n = 75) and the D group had 2 crown milling sites (n = 30).

View Article and Find Full Text PDF

Purpose: The objective of this study was to compare marginal bone loss (MBL) and clinical complications between surviving implants (SIs) and recently placed implants (RIs) splinted together to support a fixed partial restoration (FPR).

Materials And Methods: This retrospective study employed the medical records of patients treated with implant-supported FPRs in the Maccabi-Dent Dental Clinic. Patients were included if they were over the age of 18 years, were treated with RIs adjacent to existing SIs that had previously supported FPRs for more than 1 year, and the RIs and SIs were splinted to support new FPRs.

View Article and Find Full Text PDF

The effects of different heights of ti-base abutments on the color of anterior screw-retained zirconia restorations fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) technologies may affect the optical clinical outcome. The purpose of this study was to measure and compare the color parameters of zirconia crowns in different shades on ti-base abutments. Identical specimens (N = 160) were milled to restore the screw-retained central maxillary incisor crown, using 5% mol yttria zirconia (5Y-TZP).

View Article and Find Full Text PDF

Background: The purpose of this study was to measure and compare the strain levels in the peri-implant bone as generated by the blade-like implant (BLI) and the screw-type implant (STI) with two different internal connections (hexagonal and conical) and with a 1:1 and 2:1 crown/implant (C/I) ratio. Methods: The implants (BLI and STI) were placed into sawbones according to the manufacturer’s protocol. Two strain gauges, horizontal and vertical to the implant axis, were placed around each implant on the bone surface 1 mm from the cervical part.

View Article and Find Full Text PDF

Purpose: To estimate the effects of the thermal cycling (TC) process on the metal surfaces of Locators, as well as retention loss, and the correlation between them.

Materials And Methods: Twenty-five new Locator R-Tx were included in the study. Four areas were marked on each Locators' patrix metal surface and scanned using a confocal scanner (μsurf explorer; NanoFocus).

View Article and Find Full Text PDF

Aim: We assess the accuracy of torque controllers after several aging processes and the bacterial leakage on implant-abutment complexes (IAC).

Methods: A total of 12 spring-type and 12 friction-type torque controllers and 48 IAC (24 conical and 24 hexagonal connections) were evaluated. Chemical, mechanical, temperature, and pressure-aging methods were applied individually to replicate clinical use.

View Article and Find Full Text PDF

Purpose: The objective of this study was to report implant survival rates, marginal bone loss, and the impact of prosthesis type among patients with type 2 diabetes mellitus (DMT2), with high hemoglobin A1C (HbA1c) values.

Materials And Methods: This retrospective study utilized patient medical records from an oral surgeon's office. Patients who had moderately or poorly controlled DMT2 with HbA1c values up to 10% were reviewed.

View Article and Find Full Text PDF

Purpose: To investigate the recovery of loss of smell and taste among recovered COVID-19 patients.

Materials And Methods: This cross-sectional follow-up study is a sequel to a study by Biadsee et al. Among the previous study population of 128 non-hospitalized patients, positive for COVID-19 by reverse transcription-polymerase chain reaction (RT-PCR), 97 patients participated in a survey designed for this study.

View Article and Find Full Text PDF

Purpose: This in vitro study was designed to compare bacterial adhesion to zirconia versus lithium disilicate crowns after artificial aging.

Materials And Methods: Seventy-five discs were tested in this study: 25 Cr-Co base metal discs (control), 25 zirconia discs, and 25 lithium disilicate discs. Each sample was polished and glazed appropriately.

View Article and Find Full Text PDF

The objective of this in vivo study was to compare bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) values of a new implant, designed to be inserted without bone preparation, using two different preparation protocols: no site preparation and prior limited cortical perforation, versus the values of a control implant using a conventional drilling protocol. Forty-one implants were inserted in 13 rabbits. Thirteen test implants with a new thread design were inserted using no bone preparation (NP), 14 test implants were inserted with limited cortical perforation (CP), and 14 conventional implants served as control.

View Article and Find Full Text PDF

Objective: The coronavirus disease 2019 (COVID-19) pandemic poses a threat to global health. Early diagnosis is an essential key to limit the outbreak of the virus.

Study Design: Case series, study conducted between March 25, 2020, and April 15, 2020.

View Article and Find Full Text PDF

Innovative implant thread design enables timesaving one-stage insertion, with no need for prior osteotomy. This technique may impair bone and implant surface. The aim of this study was to investigate the strain levels produced in surrounding bone by this new treatment approach during and after implant placement and the effect of high insertion torque on the surface microstructure of the implants.

View Article and Find Full Text PDF

The objective of this study was to compare the efficacy of supportive periodontal therapy (i.e. scaling and root planning, SRP) alone, versus a chemical device silica dioxide (SiO2) colloidal solutions (SDCS) used in association with SRP in the treatment of chronic periodontitis in adult patients.

View Article and Find Full Text PDF

Statement Of Problem: Although the Periotest has been shown to provide reliable information about initial implant stability, whether Periotest values (PTVs) can be correlated with the stability of implants in function for several years is unclear.

Purpose: The purpose of this prospective clinical study was to investigate implant stability by using PTVs, as well as changes in stability and peri-implant marginal bone levels (as measured by radiographs) over a 3-year follow-up period. The exploratory hypothesis was that there is a significant correlation between PTVs and bone loss around the implant and that PTVs can provide predictive information about marginal bone-level changes and implant stability over time.

View Article and Find Full Text PDF

Purpose: The objective of this study was to assess whether long-term implant survival rates and bone loss in patients with moderately controlled type 2 diabetes is similar to the rates reported in the nondiabetic population.

Materials And Methods: This retrospective observational study utilized patient medical records from a general practitioner's dental office. The records of patients who had moderately controlled type 2 diabetes with hemoglobin A1C (HbA1c) up to 8% and glucose level below 150 mg/dL were reviewed, as patients with HbA1c up to 7% are considered to be well-controlled type 2 diabetes.

View Article and Find Full Text PDF

SureFil SDR is a flowable resin-based composite that allows a single incremental bulk placement. The marginal seal of SureFil SDR at the gingival margins of class II restorations located apical to the cemento-enamel-junction (CEJ) has not been adequately evaluated compared to those located occlusal to the CEJ. Forty class II cavities were prepared in human molars.

View Article and Find Full Text PDF

Multiple recession defects in the dentition of the patients are routinely encountered in clinical practice and as such present a challenge for clinicians. Periodontal plastic surgical procedures aim to restore both esthetics as function in periodontal tissues. The objective of this study was to evaluate and compare the clinical efficacy of using a tunnel technique with a collagen matrix to cover multiple recessions in the maxilla or mandible.

View Article and Find Full Text PDF

Aim: This study investigated strain levels during and after implant insertion, and during and after simulated mastication, in splinted and nonsplinted restorations with different occlusal schemes.

Materials And Methods: Fresh bovine bone resembling type I jawbone was collected. Strain gauges were placed at each implant's neck, one horizontally and one vertically.

View Article and Find Full Text PDF

The purpose of this work is to evaluate changes in temperature of one-piece titanium implant surface during the setting of acrylic resin temporary crowns and to correlate thermal changes to implant diameter. Thirty-three one-piece implants (ARRP, Alpha-Biotec) were divided into 3 groups according to diameter size (G1=3 mm, G2=3.3 mm, G3=3.

View Article and Find Full Text PDF

Denture adhesives are widely used in dentistry. The growth of Candida albicans on the denture base is common on both jaws, particularly in elderly patients. A strong correlation has been found between the growth of Candida albicans and dentures, potentially leading to denture stomatitis.

View Article and Find Full Text PDF

The final outcome of dental treatment needs to be not only clinically sufficient, but also esthetically pleasing. Bilateral symmetry in the maxillary incisor teeth is of significant importance in esthetic dentistry. In restorative dentistry, symmetry refers to the appearance of balance around the dental midline.

View Article and Find Full Text PDF

The present study was based on the screening of procedures and materials used by dentists in constructing complete removable dental prostheses, considering their professional background and years of experience. Questions arose regarding differences and similarities within the local dental society, of which approximately 75% were trained in Europeans countries with differences in academic background, and compared to international dentistry. A questionnaire web site was used in order to anonymously collect answers to the survey by general practicing and specialist dentists.

View Article and Find Full Text PDF

Introduction: The success of implant-supported restorations is dependent on proper treatment planning, effective communication within the clinical team, and the use of appropriate methods and materials in the dental laboratory. The objective of this study was to determine collaboration trends between dentists and laboratories and to assess the common methods and materials involved in fabricating implant-supported restorations.

Methods: Questionnaires were distributed to dental laboratories and technicians.

View Article and Find Full Text PDF