A smartphone-based technology combining a digital stethoscope (DS) with simultaneous phonocardiography (PCG) and 1-lead electrocardiogram (ECG) is available. The aim of the present study was to evaluate the sensitivity and specificity of the DS for the detection of heart disease in cats considering transthoracic echocardiography as gold standard. The study is prospective and observational inlcuding 42 client-owned cats.
View Article and Find Full Text PDFIn veterinary medicine, the radiographic assessment of right heart enlargement (RHE) is essentially subjective. The aim of this study was to evaluate the vertebral right heart index (VRHi) as a new quantitative radiographic method to detect RHE in dogs. This was a multicenter, retrospective, observational study, including dogs with RHE and control dogs.
View Article and Find Full Text PDFGlobe-LFMC 2.0, an updated version of Globe-LFMC, is a comprehensive dataset of over 280,000 Live Fuel Moisture Content (LFMC) measurements. These measurements were gathered through field campaigns conducted in 15 countries spanning 47 years.
View Article and Find Full Text PDFBackground: Artificial intelligence (AI) could improve accuracy and reproducibility of echocardiographic measurements in dogs.
Hypothesis: A neural network can be trained to measure echocardiographic left ventricular (LV) linear dimensions in dogs.
Animals: Training dataset: 1398 frames from 461 canine echocardiograms from a single specialist center.
Introduction: Atrial fibrillation secondary to dilated cardiomyopathy (DCM) frequently affects large-breed dogs. The aim of the present study was to identify risk factors for the development of atrial fibrillation in dogs of different breeds with an echocardiographic diagnosis of DCM.
Methods: In this multicenter retrospective study, we searched the electronic databases of five cardiology referral centers for dogs with an echocardiographic diagnosis of DCM.
Background: Pulmonary stenosis (PS) usually is evaluated using echocardiography. A multiparametric approach, in addition to the maximum pressure gradient (PG), might be indicated to better characterize PS severity and address its management.
Hypothesis/objectives: Our hypothesis was that right heart size and function are associated with echocardiographic and clinical severity of pulmonary stenosis in dogs.
Background: Three-dimensional (3D) echocardiography and 2-dimensional (2D) strain measurements of the right ventricle (RV) are important indices in humans with pulmonary hypertension (PH) and need further evaluation in dogs with PH.
Objectives: To evaluate various RV size and function indices in dogs with PH and to examine differences between pre- and postcapillary PH.
Animals: A total of 311 client-owned dogs: 100 dogs with PH, 31 with postcapillary and 69 with precapillary PH, and 211 healthy control dogs.
Although vascular plugs for the closure of patent ductus arteriosus (PDA) have been validated in dogs, studies are lacking on its use as a first-choice device with a transjugular approach. The present case series describes the transvenous right jugular embolization of PDA using an Amplatzer Vascular Plug II in seven dogs of different ages, breeds, and body weights. Complete closure of the PDA was demonstrated in all cases.
View Article and Find Full Text PDFPercutaneous balloon dilation was performed in a Rhodesian Ridgeback and in an American Staffordshire Terrier affected by cor triatriatum dexter (CTD). Both cases had ascites without jugular venous distension or pleural effusion. In both dogs the CTD presented a perforated membrane but with different morphology: in one case the coronary sinus entered the caudal chamber of the CTD together with the caudal vena cava.
View Article and Find Full Text PDFThe purpose of this study was to evaluate the reliability of precordial leads for the detection of right ventricular enlargement (RVE) in dogs. This was a prospective observational study. The RVE was defined by echocardiography.
View Article and Find Full Text PDFTwo French bulldogs and one English bulldog affected by pulmonary valve stenosis and referred for pulmonary balloon valvuloplasty were diagnosed with different abnormalities of the external jugular veins. The diagnosis included unilateral absence of the right external jugular vein and bilateral hypoplasia of the external jugular veins, associated with persistent left cranial vena cava. Vascular ultrasound and computed tomography were used for the diagnosis.
View Article and Find Full Text PDFPulmonary valve stenosis (PS) in dogs is usually suspected due to the presence of a heart murmur and clinical signs. Echocardiography is needed to confirm the diagnosis and define the severity of PS. This retrospective study evaluated the utility of clinical and electrocardiographic (ECG) findings in the prediction of PS severity.
View Article and Find Full Text PDFBackground: There is currently a lack of reference intervals (RIs) for the novel measures like 3-dimensional (3D) echocardiography or speckle-tracking strain for assessment of right ventricular (RV) structure and function.
Objectives: To generate RIs and to determine the influence of age, heart rate, and body weight (BW) on various RV function indices using a dedicated RV software for 3D RV end-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), global and free wall RV longitudinal strain (RVLS), end-diastolic area (RVEDA), end-systolic area (RVESA), fractional area change (FAC), tricuspid annular plane systolic excursion (TAPSE), and tissue Doppler imaging (TVI)-derived systolic myocardial velocity of the lateral tricuspid annulus (S').
Animals: Healthy adult client-owned dogs (n = 211) of various breeds and ages.
Background: There is no commonly shared severity score for myxomatous mitral valve disease (MMVD) based on routinely acquired echocardiographic variables.
Hypothesis/objectives: To propose an easy-to-use echocardiographic classification of severity of MMVD in dogs.
Animals: Five hundred and sixty dogs with MMVD.
Symmetric dimethylarginine (SDMA) is a serum biomarker of renal damage in dogs. Moreover, SDMA concentration is an independent predictor of development of severe heart failure (HF) in humans with cardiac disease. This study evaluates whether the serum concentration of SDMA in dogs with myxomatous mitral valve disease (MMVD) is influenced by the severity of heart disease, pulmonary hypertension (PH) and treatment of HF.
View Article and Find Full Text PDFLeft atrial enlargement (LAE) is a well-known negative prognostic factor in dogs with myxomatous mitral valve disease (MMVD). Left atrial-to-aortic root ratio (LA/Ao) is the most commonly used method to evaluate left atrial (LA) size in dogs, while the left atrial anteroposterior diameter (LAD) has been proposed as an additional measurement of LA size in different species. The aim of this study was to establish a normal reference range of LAD normalized to body weight (LADn) in dogs using allometric scales, and to evaluate the agreement between LADn and LA/Ao in the detection of LAE in dogs with MMVD.
View Article and Find Full Text PDFA 2-year-old American Pit Bull dog was presented for surgical evaluation of imperforate cor triatriatum dexter (CTD) and patent foramen ovale (PFO). Echocardiography identified an imperforate CTD associated with a right-to-left shunting PFO and valvular pulmonary stenosis. A 2-step interventional and surgical approach was used.
View Article and Find Full Text PDFIn canine electrocardiography, the reference interval of the ventricular mean electrical axis (MEA) is between +40° and +100°. MEA values in dogs can be influenced by the patient position as well as by the shape of the thorax. The aim of this study was to evaluate the MEA in healthy Doberman Pinschers, hypothesizing that some present a left shift of the MEA.
View Article and Find Full Text PDFThe feasibility of the home monitoring of heart rate (HR) and rhythm through ECG tracings recorded by owners with a smartphone ECG device was evaluated in dogs. Smartphone ECG tracings were recorded by owners at home using a single-lead ECG device and sent via email for interpretation. A questionnaire was prepared to assess the owner's opinion regarding this home monitoring service.
View Article and Find Full Text PDFBackground: Right ventricular (RV) enlargement and dysfunction are associated with prognosis in humans with pulmonary hypertension (PH).
Hypothesis/objectives: To assess RV size and systolic function in dogs with PH and to determine if they are associated with disease severity and right-sided congestive heart failure (R-CHF).
Animals: 89 dogs with PH and 74 healthy dogs.
The aims of this study were to assess if ECG-gated 16-multidetector CT (MDCT) provides sufficient temporal and spatial resolution to evaluate canine coronary arteries and provide a detailed description of their anatomy. A total of 24 dogs were included. Images were reviewed to assess: (1) coronary artery opacification and dominance; (2) choice of optimal R-R ECG reconstruction interval for both left coronary artery (LCA) and right coronary artery (RCA); (3) branching patterns of the left main coronary artery (LMCA); and (4) diameter and length of the LCA and RCA and classification of their branches by adapting a previously described segmental coding system.
View Article and Find Full Text PDFA 6-month-old German shepherd dog was presented for progressive paraparesis. Multiple arteriovenous fistulae and hyperostosis of the thoracic vertebrae with secondary thoraco-lumbar spinal cord compression were diagnosed. Arteriovenous spinal fistula is a rare condition but should be considered as a differential diagnosis in young dogs with progressive paraparesis.
View Article and Find Full Text PDF