Publications by authors named "Oostdijk A"

Introduction: This study investigates the incidence of extrahepatic perfusion and incomplete hepatic perfusion at intraoperative methylene blue testing and on postoperative nuclear imaging in patients undergoing hepatic arterial infusion pump (HAIP) chemotherapy.

Methods: The first 150 consecutive patients who underwent pump implantation in the Netherlands were included. All patients underwent surgical pump implantation with the catheter in the gastroduodenal artery.

View Article and Find Full Text PDF

Background: Radium-223 (Ra-223), an alpha-emitting radiopharmaceutical, established an improved overall survival and health-related quality of life (HRQoL) in symptomatic metastatic castration-resistant prostate cancer (mCRPC) patients. However, effects on pain were not specifically evaluated. Here we assess integrated HRQoL, pain, and opioid use in a contemporary, more extensively pretreated, symptomatic and asymptomatic mCRPC population.

View Article and Find Full Text PDF

The ALSYMPCA study established a 3.6 month Overall Survival (OS) benefit in metastatic Castration Resistant Prostate Cancer (mCRPC) patients treated with Radium-223 dichloride (Ra-223) over placebo. Here we report clinical outcomes of Ra-223 treatment in a nonstudy population.

View Article and Find Full Text PDF

Background: We evaluated the diagnostic implications of a small-voxel reconstruction for lymph node characterization in breast cancer patients, using state-of-the-art FDG-PET/CT. We included 69 FDG-PET/CT scans from breast cancer patients. PET data were reconstructed using standard 4 × 4 × 4 mm and small 2 × 2 × 2 mm voxels.

View Article and Find Full Text PDF

Background: The coronary calcium score (CCS) provides independent diagnostic and prognostic information on top of myocardial perfusion imaging (MPI) in patients suspected for coronary artery disease, but requires an additional computed tomography (CT) scan.

Objective: We investigated the accuracy and inter-reader reproducibility of visual estimation of the CCS on the CT used for attenuation correction.

Methods: 250 patients undergoing single photon emission computed tomography MPI and Agatston CCS were included.

View Article and Find Full Text PDF

Background: Performing both single photon emission computerized tomography (SPECT) and coronary computed tomography angiography (CCTA) in patients suspected for coronary artery disease (CAD) leads to increased radiation exposure. We evaluated the need for additional imaging and following implications for radiation exposure of a sequential SPECT/computed tomography (CT) algorithm.

Methods And Results: 5018 consecutive patients without history of CAD were referred for stress-first SPECT and coronary artery calcium (CAC) scoring.

View Article and Find Full Text PDF

Background: The decreasing image quality in heavier patients can be compensated by administration of a patient-specific dose in myocardial perfusion imaging (MPI) using a cadmium zinc telluride-based SPECT camera. Our aim was to determine if the same can be achieved when using a conventional SPECT camera.

Methods: 148 patients underwent SPECT stress MPI using a fixed Tc-99m tetrofosmin tracer dose.

View Article and Find Full Text PDF

Unlabelled: Myocardial perfusion imaging (MPI) with SPECT is widely adopted in clinical practice but is associated with a relatively high radiation dose. The aim of this study was to determine the minimum product of tracer dose and scan time that will maintain diagnostic value for cadmium zinc telluride (CZT) SPECT MPI.

Methods: Twenty-four patients underwent clinically indicated stress MPI using CZT SPECT and a body weight-dependent (3 MBq/kg) (99m)Tc-tetrofosmin tracer dose.

View Article and Find Full Text PDF

Unlabelled: A major disadvantage of (18)F-FDG PET involves poor detection of small lesions and lesions with low metabolism, caused by limited spatial resolution and relatively large image voxel size. As spatial resolution and sensitivity are better in new PET systems, it is expected that small-lesion detection could be improved using smaller voxels. The aim of this study was to test this hypothesis using a state-of-the-art time-of-flight PET/CT device.

View Article and Find Full Text PDF

Background: Guidelines for SPECT myocardial perfusion imaging (MPI) traditionally recommend a fixed tracer dose. Yet, clinical practice shows degraded image quality in heavier patients. The aim was to optimize and validate the tracer dose and scan time to obtain a constant image quality less dependent on patients' physical characteristics.

View Article and Find Full Text PDF

Objective: Regadenoson is a recently approved selective adenosine-2A receptor agonist to induce pharmacological stress in myocardial perfusion imaging (MPI) procedures using a single bolus injection.

Material And Methods: We included 123 patients referred for MPI because of suspected coronary arterial disease (CAD). Of these, 66 patients underwent a regadenoson stress test and 57 patients underwent an adenosine stress test preceding standard myocardial SPECT imaging.

View Article and Find Full Text PDF

Purpose: Coronary artery calcium (CAC) scores influence the pre-test likelihood of ischemia in patients undergoing myocardial perfusion imaging (MPI). We investigated the influence of CAC score knowledge on the visual interpretation of MPI in patients referred for the diagnostic work-up of suspected coronary artery disease.

Methods: We retrospectively analyzed symptomatic patients who were referred for MPI.

View Article and Find Full Text PDF

Purpose: Recently introduced ultrafast cardiac SPECT cameras with cadmium zinc telluride-based (CZT) detectors may provide superior image quality allowing faster acquisition with reduced radiation doses. Although the level of concordance between conventional SPECT and invasive fractional flow reserve (FFR) measurement has been studied, that between FFR and CZT-based SPECT is not yet known. Therefore, we aimed to assess the level of concordance between CZT SPECT and FFR in a large patient group with stable coronary artery disease.

View Article and Find Full Text PDF

Purpose: High coronary artery calcium (CAC) scores are associated with a high likelihood of ischaemia and obstructive coronary disease. Myocardial perfusion imaging (MPI) is a key investigation to determine the need for revascularization. However, the value of MPI in presence of extensive CAC has so far only been demonstrated in asymptomatic patients, whereas its value in symptomatic patients remains largely unclear.

View Article and Find Full Text PDF

Purpose: To assess the capability of a zero coronary artery calcium (CAC) score to help exclude flow-limiting coronary artery disease (CAD) in a homogeneous population with stable anginal complaints and a low-to-intermediate pretest likelihood.

Materials And Methods: The study protocol had institutional ethics committee approval, with written informed consent from all patients. Between 2009 and 2011, a total of 3501 consecutive stable patients without known CAD underwent prospectively simultaneous myocardial perfusion imaging and CAC scoring on a hybrid, 64-section single photon emission computed tomography (SPECT)/computed tomography (CT) scanner.

View Article and Find Full Text PDF

Background: A standardized diagnostic program, initiated to reduce the length of the diagnostic track and to improve application of diagnostic tools for patients referred with suspicious abnormalities on standard chest radiographs, was evaluated.

Methods: The findings on integrated positron emission tomography/computed tomography (PET-CT) determined the choice of invasive investigations to be performed the same day. Diagnostic results, time courses, and number and sorts of applied invasive investigations were assessed.

View Article and Find Full Text PDF

Purpose: The new ultrafast cardiac single photon emission computed tomography (SPECT) cameras with cadmium-zinc-telluride (CZT)-based detectors are faster and produce higher quality images as compared to conventional SPECT cameras. We assessed the need for additional imaging, total imaging time, tracer dose and 1-year outcome between patients scanned with the CZT camera and a conventional SPECT camera.

Methods: A total of 456 consecutive stable patients without known coronary artery disease underwent myocardial perfusion imaging on a hybrid SPECT/CT (64-slice) scanner using either conventional (n = 225) or CZT SPECT (n = 231).

View Article and Find Full Text PDF

Cardiac SPECT-CT is a new hybrid technique that simultaneously produces non-invasive functional information (SPECT) and anatomical information about the coronary arteries (CT). Both types of information are crucial for optimal decision making regarding coronary revascularisation. The hybrid SPECT-CT scanner is very suitable for individual patient-tailored algorithms in which SPECT based ischaemia detection can be complemented with CT coronary angiography or vice-versa.

View Article and Find Full Text PDF

Background: Lesions detected by positron emission tomography-computed tomography (PET-CT) during the analysis of thoracic tumours are often impalpable at physical examination, and subsequent ultrasound (US) may aid in finding these lesions for pathologic evaluation.

Objectives: The success rate of percutaneous US-guided biopsies of palpable and non-palpable lesions and the impact on tumour stage were studied prospectively.

Methods: Lesions, significant for diagnosis and disease stage, with metabolic activity on PET-CT and presumed appropriate for percutaneous approach under US guidance were selected for cytologic aspiration or tissue core biopsies.

View Article and Find Full Text PDF

Introduction: Incidental mediastinal lymphadenopathy challenges pulmonologists to decide on eventual further diagnostic steps. The aim of this study was to characterize unexpected mediastinal findings by imaging and pathologic analysis.

Methods: Entry criterion for this prospective explorative study was mediastinal lymphadenopathy as an incidental finding on computed tomography (CT) scans made for indications other than the analysis and staging of neoplasms.

View Article and Find Full Text PDF

Background: After induction treatment restaging of mediastinal disease in patients with stage III non-small cell lung cancer (NSCLC) may lead to selection of candidates for further surgical treatment. Nodal down-staging is the best predictive characteristic for proceeding with surgery. We report our experience in restaging with endoscopic ultrasound-guided fine needle aspirations (EUS-FNA) and with repeated integrated positron emission tomography and computed tomography (PET-CT).

View Article and Find Full Text PDF

D-dimer test combined with clinical probability assessment has been proposed as the first step in the diagnostic work-up of patients with suspected pulmonary embolism (PE). In a prospective management study we investigated the safety and efficiency of excluding PE by a normal D-dimer combined with a low or moderate clinical probability. Of the 202 study patients this combination ruled out PE in 64 (32%) patients.

View Article and Find Full Text PDF

We describe a patient with frontal hygroma after spinal anesthesia--a rare complication. This condition should be considered in patients after spinal anesthesia with persisting orthostatic headache. Risk factors include ventriculo-peritoneal shunt or brain atrophy caused by old age.

View Article and Find Full Text PDF

Patients with suspected pulmonary embolism often receive heparin therapy for hours to days before ventilation/perfusion scintigraphy is completed. We assessed to what extent the lung scan classification and pulmonary vascular perfusion changed over a period of 2-4 days of full anticoagulant therapy. In 312 consecutive patients with at least one segmental perfusion defect on the initial perfusion scan, classification of both the initial and the final lung scan allowed us to study alteration in scan classification.

View Article and Find Full Text PDF

Background: The main purpose of ventilation scanning, as adjunct to perfusion lung scintigraphy, in acute pulmonary embolism is to allow for the classification of segmental perfusion defects as mismatched, which is generally accepted as proof for the presence of pulmonary embolism. We examined whether this function of the ventilation scan could be replaced by the chest X-ray.

Methods: In 389 consecutive patients with suspected pulmonary embolism and at least one segmental perfusion defect we classified the ventilation/perfusion (V/Q) scan and chest X-ray/perfusion (X/Q) scan as either mismatched or matched.

View Article and Find Full Text PDF