Objectives: The purpose of this in vitro study was to evaluate the trueness of four commercially available intraoral scanners (IOSs) on scanning different substrates that existed in the adjacent proximal contact area.
Methods: Four IOSs (TRIOS 4, TRIOS 3, Primescan, Omnicam) were used for scanning the intact enamel surface of a molar tooth, and six restorative materials (zirconia, lithium disilicate glass-ceramic, composite resin, hybrid ceramic, feldspathic ceramic, metal) that were located at the adjacent proximal contact area of the same tooth. Reference scans were obtained using an extraoral scanner (inEos X5).
Objectives: The purpose of this in vitro study was to evaluate the trueness of scanning the post space up to 20 mm with an intraoral scanner (IOS).
Methods: We captured 20-, 18-, 16-, 14-, 12-, and 10-mm length post space scans using an IOS (Primescan) eight times each by shortening the apical 2 mm end of the same mandibular canine tooth. The reference impressions of each length group were taken using a light-body polyvinyl siloxane impression material and were scanned with an extraoral scanner.
Objectives: The purpose of this in vitro study was to evaluate the influence of the ceramic thickness, cement shade, and airborne-particle abrasion of the titanium on the final color of titanium base cemented lithium disilicate glass-ceramic restorations.
Method And Materials: In total, 144 lithium disilicate glass-ceramic disks of three thicknesses (0.5, 1.
Objectives: The aim of this study was to evaluate the outcomes of immediate fixed full-arch prostheses supported by axial or tilted narrow-diameter Ti-Zr implants (3.3 mm) (Roxolid®, Institut Straumann® AG, Basel, Switzerland) (NDIs) in combination with standard-diameter implants up to 2 years' follow-up.
Materials And Methods: The study was conducted at Kocaeli University Faculty of Dentistry from 2016 to 2018.
J Oral Implantol
February 2022
The purpose of the present study was to investigate the intraobserver and interobserver reliability of 3 resonance frequency analysis (RFA) devices and to compare the implant stability quotient (ISQ) values according to implant macro design and diameter in 2 different bone densities. A total of 64 implants (Neoss ProActive; Neoss; Harrogate, UK) of varying diameters (3.5 and 4.
View Article and Find Full Text PDFInt J Prosthodont
October 2021
Purpose: To evaluate the trueness of digital impressions of different composite resin materials that can be used for core build-ups in clinical practice.
Materials And Methods: A maxillary central incisor was prepared and scanned with an intraoral scanner (Primescan, Dentsply Sirona). Ten composite resin specimens (in three groups: universal composite; flowable composite; and bulk fill resin composite) were milled in the same dimensions of the prepared tooth and scanned.
Purpose: To compare the accuracy of six intraoral scanners in two different partially edentulous maxillary models and to evaluate the effect of scanning sequence on accuracy.
Materials And Methods: Maxillary Kennedy Class I and Class IV situations were used as reference models. The reference datasets were obtained by scanning the models using a highly accurate industrial scanner (ATOS Core 80, GOM).
Statement Of Problem: The digital scan accuracy of different intraoral scanners (IOSs) for long-span fixed prosthesis and the effect of the starting quadrant on accuracy is unclear.
Purpose: The purpose of this in vitro study was to evaluate the accuracy of 6 IOSs for complete-arch and prepared teeth digitally isolated from the complete-arch and to determine the effect of the starting quadrant on accuracy.
Material And Methods: A maxillary model containing bilaterally prepared canines, first molar teeth, and edentulous spans between the prepared teeth was used.
Statement Of Problem: The accuracy of intraoral scanners (IOSs) has been evaluated. However, testing their performance when scanning deep endocrown preparations is lacking.
Purpose: The purpose of this in vitro study was to assess the effect of pulpal chamber extension depth (PCED) on scanning accuracy and to compare the accuracy of different IOSs on scanning different PCEDs.
J Adv Prosthodont
October 2020
Purpose: The aim of this study was to evaluate the accuracy of six recently introduced intraoral scanners (IOSs) for single crown preparations isolated from the complete arch, and to determine the effect of scanning sequence on accuracy.
Materials And Methods: A complete arch with right and left canine preparations for single crowns was used as a study model. The reference dataset was obtained by scanning the complete arch using a highly accurate industrial scanner (ATOS Core 80, GOM GmbH).
Objective: This study evaluated the effect of low-level laser therapy (LLLT) on postoperative pain in children undergoing primary molar extraction.
Materials And Methods: This randomized, controlled-crossover, double-blind clinical trial was conducted with 37 children requiring bilateral extraction of primary molars. In one tooth (LLLT group), a GaAlAs diode laser (wavelength, 810 nm; continuous mode, output power 0.
The current literature suggests that low-level laser stimulation of the PC 6 acupuncture points may prevent gagging. This study aimed to determine if low-level laser therapy (LLLT) can reduce the gag reflex in children undergoing intraoral maxillary radiography. This randomized, controlled, double-blind clinical trial was conducted with 25 children with moderate-to-very severe gag reflexes who required bilateral periapical radiographic examination of the maxillary molar region.
View Article and Find Full Text PDFPurpose: To evaluate the in vitro diffusion of 2-hydroxyethyl methacrylate (HEMA) from the resin cements through different thicknesses of dentin using high-performance liquid chromatography (HPLC) at two time intervals.
Methods: 60 freshly extracted caries- and restoration-free human third molar teeth were used in this study. Standardized box-shaped Class I inlay cavities (6 mm long, 3 mm wide and 2 mm deep) were prepared in all teeth with a high-speed handpiece mounted on a standard cavity machine.
Purpose: To evaluate the effects of different types of luting cements and different colors of zirconium cores on the final color of the restoration that simulates implant-supported fixed partial dentures (FPDs) by using a titanium base on the bottom.
Materials And Methods: One hundred and twenty zirconium oxide core plates (Zr-Zahn; 10 mm in width, 5 mm in length, 0.5 mm in height) were prepared in different shades (n = 20; noncolored, A2, A3, B1, C2, D2).
Background And Objective: The laser debonding procedure of adhesively luted all-ceramic restorations is based on the ablation of resin cement due to the transmitted laser energy through the ceramic. The purpose of this study was to determine the effect of Er:YAG laser irradiation transmitted through a dental ceramic on five different resin cements.
Materials And Methods: Five different resin cements were evaluated in this study: G-Cem LinkAce, Multilink Automix, Variolink II, Panavia F, and Rely X Unicem U100.
Purpose: The aim of this study was to evaluate the diffusion of 2-Hydroxyethyl methacrylate (HEMA) from resin cement through dentin both affected and unaffected by caries through high-performance liquid chromatography (HPLC) at two time intervals.
Materials And Methods: Ten freshly extracted restoration-free, caries-free and ten extracted carious human third molar teeth were used in this study. Standardized box-shaped Class I inlay cavities (6 mm long, 3 mm wide, 2 mm deep) were prepared in all teeth with a high-speed handpiece mounted on a standard cavity machine.
Objectives: The purpose of this study was to evaluate the effect of three provisional cements and two cleaning techniques on the final bond strength of porcelain laminate veneers.
Methods: The occlusal third of the crowns of forty molar teeth were sectioned and embedded in autopolymerizing acrylic resin. Dentin surfaces were polished and specimens were randomly divided into four groups (n=10).
The purpose of this study was to determine colour changes in a composite cured with tungsten-halogen, light-emitting diode (LED) or a plasma arc after 5 years. Five specimens 10 mm in diameter and 2 mm in height were prepared using Hybrid (Clearfil AP-X) composite for each test group. The corresponding specimens were cured with a tungsten-halogen curing light, a LED unit or with a plasma arc.
View Article and Find Full Text PDFClin Oral Investig
September 2008
The purpose of this study was to evaluate the temperature rise during polymerization of three different provisional materials by direct method on two different dentin disc thicknesses. Two autopolymerizing; bis-acrylic composite (Fill-in; Kerr), polymethyl methacrylate (Temdent; Weil Dental), and one light polymerizing composite (Revotek LC; GC) provisional restoration materials were used in this study. Sixty dentin discs were prepared from extracted molars (diameter, 5 mm; height, 1 or 2 mm).
View Article and Find Full Text PDF