Publications by authors named "Omar Yusef Kudsi"

Background: This study aims to compare clinical outcomes and financial cost of intraperitoneal onlay mesh (IPOM) versus retromuscular (RM) repairs in robotic incisional hernia repairs (rIHR).

Methods: Patients who underwent either IPOM or RM elective rIHR from 2012 to 2022 were included. Demographics, operative details, postoperative outcomes, and hospital costs were directly compared.

View Article and Find Full Text PDF

In this review, the advantages of the robotic platform in rTAPP are presented and discussed. Against the background of the unchanged results of conventional TAPP for decades (approx. 10% chronic pain and approx.

View Article and Find Full Text PDF

Objective: A universal resident robotic surgery training pathway that maximizes proficiency and safety has not been defined by a consensus of surgical educators or by surgical societies. The objective of the Robotic Surgery Education Working Group was to develop a universal curriculum pathway and leverage digital tools to support resident education.

Design: The two lead authors (JP and YN) contacted potential members of the Working Group.

View Article and Find Full Text PDF

Background: The increased digitization in robotic surgical procedures today enables surgeons to quantify their movements through data captured directly from the robotic system. These calculations, called objective performance indicators (OPIs), offer unprecedented detail into surgical performance. In this study, we link case- and surgical step-specific OPIs to case complexity, surgical experience and console utilization, and post-operative clinical complications across 87 robotic cholecystectomy (RC) cases.

View Article and Find Full Text PDF

Background: The coronavirus disease 2019 (COVID-19) pandemic strained the health care sector, putting severe constraints on surgical departments. In this study, we evaluate the impact of the pandemic on the outcomes of patients undergoing robotic cholecystectomy (RC).

Patients And Methods: Patients who underwent RC 1 year before and after March 2020 were included in this retrospective study and assigned accordingly to the pre or post-COVID group.

View Article and Find Full Text PDF

Objective: To establish the learning curve of multiport robotic cholecystectomy (MRC).

Patients And Methods: A retrospective analysis of patients undergoing MRC was performed. A cumulative sum analysis helped define the learning curve through the evaluation of skin-to-skin (STS) time and postoperative complications rate.

View Article and Find Full Text PDF

The purpose of this study is to compare the clinical outcomes of robotic ventral hernia repair (RVHR) between smokers and non-smokers. Data for patients undergoing RVHR between 2012 and 2022 were collected. Patients were assigned to either smoking (+) or smoking (-) groups, according to their smoking status in the last 3 months prior to their procedure.

View Article and Find Full Text PDF

The elderly population are at an increased risk of perioperative morbidity and mortality due to their disease profile. Minimally invasive surgery and in particular the robotic approach may improve the outcomes of cholecystectomy in the elderly. Patients who underwent robotic cholecystectomy (RC) and were older than 65 at the time of the procedure were included in this retrospective study.

View Article and Find Full Text PDF

Background: We sought to study the impact of antithrombotics(antiplatelets and anticoagulants) on robotic ventral hernia repair(RVHR).

Methods: RVHR cases were divided into antithrombotic (AT) (-) and AT (+) groups. After comparing both groups, a logistic regression analysis was performed.

View Article and Find Full Text PDF

Background: As obese adults often suffer from gallbladder disease, more data on postoperative outcomes following robotic cholecystectomy(RC) is needed.

Methods: RC candidates with a body mass index(BMI) > 30 kg/m were included. Postoperative course was documented and analyzed.

View Article and Find Full Text PDF

Background: As robotic ventral hernia repair(VHR) adoption increases, real-world evidence is needed to ensure appropriate utilization.

Methods: Data for open and robotic VHR(OVHR, RVHR) was retrospectively analyzed. Outcomes and costs were compared via inverse probability treatment weighting using propensity scores to estimate the average treatment effect on the treated for RVHR.

View Article and Find Full Text PDF

Background: Ventral hernia remains as one of the most performed procedures worldwide. With the aging of the population and increasing comorbidities, it is common for ventral hernia to coexist with other pathologies that require surgery. Patients may opt for concomitant repairs while undergoing ventral hernia surgery.

View Article and Find Full Text PDF

Background And Objectives: To estimate the average treatment effect on the treated (ATT) and to assess the clinical outcomes in two different types of mesh in robotic Rives-Stoppa (rRS) ventral hernia repair (VHR).

Methods: A retrospective analysis of a robotic VHR database between February 1, 2013 and May 31, 2022. Patients who underwent a rRS VHR were included in this study and separated into two groups depending on the mesh used: Synecor Preperitoneal Biomaterial (Synecor Pre) and Bard™ Soft.

View Article and Find Full Text PDF

The aim of this study was to compare the clinical outcomes and hospital costs associated with two different meshes in robotic transabdominal preperitoneal inguinal hernia repair (IHR). Patients who underwent IHR were assigned to either the polyester self-gripping (PSG) or the polypropylene (PP) group depending on the mesh used. A propensity score matching analysis was performed to obtain balanced populations.

View Article and Find Full Text PDF

Advancement in surgery has shifted numerous procedures to a same-day discharge (SDD) setting. In this study, we evaluated factors related to SDD after robotic transversus abdominis release (rTAR). A retrospective analysis of a prospectively maintained hernia databank was performed.

View Article and Find Full Text PDF

Background: The COVID-19 pandemic disrupted the healthcare sector and forced hospitals to limit the number of elective procedures with the goal of reducing overcrowding of wards and thus viral transmission. Recent trends for ventral hernia repair have shifted towards retromuscular techniques, which normally require a longer length of stay. Therefore, the aim of this study is to investigate the impact of the COVID-19 pandemic on clinical outcomes of robotic retromuscular ventral hernia repair (rRVHR).

View Article and Find Full Text PDF

Background: Although the advantages of laparoscopic inguinal hernia repair (LIHR) have been described, guidelines regarding robotic inguinal hernia repair (RIHR) have yet to be established, despite its increased adoption as a minimally invasive alternative. This study compares the largest single-center cohorts of LIHR and RIHR and aims to shed light on the differences in outcomes between these two techniques.

Methods: Patients who underwent LIHR or RIHR over an 8-year period were included as part of a retrospective analysis.

View Article and Find Full Text PDF

Purpose: The purpose of this study is to prospectively evaluate surgical and quality of life (QoL) outcomes of robotic retromuscular ventral hernia repair (rRMVHR) using a new hybrid mesh in high-risk patients.

Methods: Data was prospectively collected for patients classified as high-risk based on the modified ventral hernia working group (VHWG) grading system, who underwent rRMVHR using Synecor™ Pre hybrid mesh in a single center, between 2019 and 2020. Pre-, intra- and postoperative variables including hernia recurrence, surgical site events (SSE), hernia-specific quality of life (QoL), and financial costs were analyzed.

View Article and Find Full Text PDF

Background: Obese patients have an increased incidence of ventral hernias; in over 50% of these cases, patients are symptomatic. At the same time, morbid obesity is a disease of epidemic proportions. The combination of symptomatic hernia and obesity is a challenge for the treating surgeon, because the risk of perioperative complications and recurrence increases with increasing BMI.

View Article and Find Full Text PDF

Background: Despite heightened interest in robotic transversus abdominis release (rTAR), concerns over its steep learning curve (LC) and associated challenges may limit its adoption. This study defines the operative time and morbidity-based LC of a single surgeon's experience with rTAR.

Methods: A retrospective analysis of patients undergoing rTAR over an 8-year period was conducted.

View Article and Find Full Text PDF

Objective: To describe the outcomes of RVHR with varying prosthetic reinforcement techniques.

Summary Of Background Data: As a recent addition to minimally invasive hernia repair, more data is needed to establish the long-term benefits of RVHR and to identify potential predictors of adverse outcomes.

Methods: Patients who underwent RVHR over a 7-year period were evaluated.

View Article and Find Full Text PDF