In vitro and in vivo studies attribute potent immune regulatory properties to the vitamin D receptor (VDR). Yet, it is unclear to what extend these observations translate to the clinical context of (vascular) inflammation. This clinical study evaluates the potential of a VDR agonist to quench vascular inflammation.
View Article and Find Full Text PDFObjective: Since chronic Q fever often develops insidiously, and symptoms are not always recognized at an early stage, complications are often present at the time of diagnosis. We describe complications associated with vascular chronic Q fever as found in the largest cohort of chronic Q fever patients so far.
Methods: Patients with proven or probable chronic Q fever with a focus of infection in an aortic aneurysm or vascular graft were included in this study, using the Dutch national chronic Q fever database.
Objective: To evaluate the feasibility and anatomical success of endovenous laser ablation (EVLA) of incompetent perforating veins (IPV).
Methods: All 135 consecutive patients with IPV treated with ELVA (intention-to-treat) from January 2008 to December 2013 were included. Up to the end of 2011, an 810-nm laserset (14 W) was used, and afterwards, a 1470-nm laserset (6 W) was introduced.
A large community outbreak of Q fever occurred in the Netherlands in the period 2007 to 2010. Some of the infected patients developed chronic Q fever, which typically includes pathogen dissemination to predisposed cardiovascular sites, with potentially fatal consequences. To identify the immune mechanisms responsible for ineffective clearance of Coxiella burnetii in patients who developed chronic Q fever, we compared serum concentrations of 47 inflammation-associated markers among patients with acute Q fever, vascular chronic Q fever, and past resolved Q fever.
View Article and Find Full Text PDFThe aim of this study was to describe specific histological findings of the Coxiella burnetii-infected aneurysmal abdominal aortic wall. Tissue samples of the aneurysmal abdominal aortic wall from seven patients with chronic Q fever and 15 patients without evidence of Q fever infection were analysed and compared. Chronic Q fever was diagnosed using serology and tissue PCR analysis.
View Article and Find Full Text PDFJ Infect
August 2014
Objectives: The aim of this study was to estimate the seroprevalence of Q fever and prevalence of chronic Q fever in patients with abdominal aortic and/or iliac disease after the Q fever outbreak of 2007-2010 in the Netherlands.
Methods: In November 2009, an ongoing screening program for Q fever was initiated. Patients with abdominal aortic and/or iliac disease were screened for presence of IgM and IgG antibodies to phase I and II antigens of Coxiella burnetii using immunofluorescence assay and presence of C.
We report 2 patients with symptomatic aortic aneurysm and serologic evidence of acute Q fever with positive Coxiella burnetii PCR in blood/tissue. This suggests a role for acute Q fever in aneurysm progression. Diagnostic testing for Q fever infection in patients with symptomatic aneurysms in Q fever areas is recommended.
View Article and Find Full Text PDFDelirium is a common problem in elderly patients undergoing surgery. Standard delirium care is not available at all surgical wards. We determined the incidence, risk factors, and outcomes of postoperative delirium among patients undergoing elective/emergency aortoiliac surgery at a surgical ward with high-standard delirium care.
View Article and Find Full Text PDFA 76-year-old man was referred to the Emergency Department because of collapse, epigastric pain and nausea. The patient had been diagnosed with an infrarenal aneurysm of the abdominal aorta nine years earlier. His symptoms were attributed to an aortic-duodenal fistula originating from the aneurysm.
View Article and Find Full Text PDFWe report the clinical feasibility of fluoroscopic Roentgen stereophotogrammetric analysis (FRSA), a validated method to quantify real time three-dimensional (3D) dynamic motion of stent grafts and the first clinical results after abdominal and thoracic endovascular repair (EVAR). Stent graft motion was measured at 30 (stereo) frames per second, during the cardiac cycle and in the patient after abdominal EVAR, due to respiratory action. Translational motions of the center of mass, diameter change, and rotational and axial motion could be measured.
View Article and Find Full Text PDFIsolated inflammatory aneurysm of the common iliac artery is a rare condition. Previously reported cases presented with urologic complications owing to entrapment of the ureter in the perianeurysmal fibrosis. We report a case of a healthy young man who presented with acute abdominal pain in the right lower quadrant without urologic complications mimicking acute appendicitis.
View Article and Find Full Text PDFObjective: To validate the use of fluoroscopic roentgenographic stereophotogrammetric analysis (FRSA) for its feasibility and accuracy for measuring the three-dimensional dynamic motion of stent grafts.
Methods: A digital biplane fluoroscopy setup was calibrated (Siemens Axiom Artis dBc). Stereo images were acquired of a static aortic model with a stent graft in different axial positions, imposed by a micromanipulator.
Purpose: This study was conducted to clarify the effect of the direction of pressure measurement on the pressure readout in fibrinous thrombus of the abdominal aortic aneurysm.
Methods: Three weights of 468 g (weight 1), 578 g (weight 2), and 675 g (weight 3) were molded. A specimen of human fibrinous thrombus was positioned under the weights.
Purpose: To evaluate in an in vitro model the feasibility and accuracy of Roentgen stereophotogrammetric analysis (RSA) versus computed tomography (CT) for the ability to detect stent-graft migration.
Methods: An aortic model was constructed from a 22-mm-diameter Plexiglas tube with 6-mm polytetrafluoroethylene inlays to mimic the renal arteries. Six tantalum markers were placed in the wall of the aortic tube proximal to the renal arteries.
Complete removal of an aortic endograft with suprarenal fixation is difficult. We report the use of a simple device to extract a Zenith endograft. This device is made by cutting off the tip of the cylinder of a 20-mL syringe and rounding off the edges.
View Article and Find Full Text PDFObjective: To clarify the effect of intraluminal thrombus on pressure transmission.
Methods: A saccular aneurysm was inserted into an artificial circulation system. Subsequently, the saccular aneurysm was filled with eight different human aortic aneurysm thrombus samples.