Urinalysis is attracting interest in personal healthcare management as part of a general move to improve quality of life. Urine contains various metabolites and the protein level in urine is an indicator of kidney function. In this study, a novel electrochemical sensing system based on boron-doped diamond (BDD) electrodes was developed for the detection of protein concentrations in human urine.
View Article and Find Full Text PDFOn-site monitoring of plasma drug concentrations is required for effective therapies. Recently developed handy biosensors are not yet popular owing to insufficient evaluation of accuracy on clinical samples and the necessity of complicated costly fabrication processes. Here, we approached these bottlenecks via a strategy involving engineeringly unmodified boron-doped diamond (BDD), a sustainable electrochemical material.
View Article and Find Full Text PDFSpikes are said to exhibit "memory" in that they can be altered by spikes that precede them. In retinal ganglion cell axons, for example, rapid spiking can slow the propagation of subsequent spikes. This increases inter-spike interval and, thus, low-pass filters instantaneous spike frequency.
View Article and Find Full Text PDFMonitoring drug concentration in blood and reflecting this in the dosage are crucial for safe and effective drug treatment. Most drug assays are based on total concentrations of bound and unbound proteins in the serum, although only the unbound concentration causes beneficial and adverse events. Monitoring the unbound concentration alone is expected to provide a means for further optimisation of drug treatment.
View Article and Find Full Text PDFBiosens Bioelectron
December 2022
Urine is one of the most used biological fluids for screening drug delivery and the resultant metabolites. In sports, the use of diuretics such as triamterene is considered a violation of anti-doping rules and is stipulated to be present at less than 79 nM in urine by the World Anti-Doping Agency (WADA). It is therefore important to develop effective rapid and low-cost tests for this diuretic.
View Article and Find Full Text PDFThe electrochemical behavior of oxygen (O) in blood was studied using boron-doped diamond (BDD) electrodes. Cyclic voltammogram of O in a 0.1 M phosphate buffer solution solution containing 1 × 10 M of bovine hemoglobin exhibits a reduction peak at -1.
View Article and Find Full Text PDFHearing loss affects >5% of the global population and therefore, has a great social and clinical impact. Sensorineural hearing loss, which can be caused by different factors, such as acoustic trauma, aging, and administration of certain classes of drugs, stems primarily from a dysfunction of the cochlea in the inner ear. Few therapeutic strategies against sensorineural hearing loss are available.
View Article and Find Full Text PDFMethylcobalamin, which is used for the clinical treatment of patients with neuropathy, can have an impact on the sensorineural components associated with the cochlea, and it is possible that the auditory threshold in a certain population of patients with deafness may be recovered. Nonetheless, it remains uncertain whether the action site of methylcobalamin is localized inside or outside the cochlea and which cellular or tissue element is targeted by the drug. In the present work, we developed a method to realize real-time simultaneous examination of the drug kinetics in two separate locations using boron-doped diamond microelectrodes.
View Article and Find Full Text PDFIn mammals, audition is triggered by travelling waves that are evoked by acoustic stimuli in the cochlear partition, a structure containing sensory hair cells and a basilar membrane. When the cochlea is stimulated by a pure tone of low frequency, a static offset occurs in the vibration in the apical turn. In the high-frequency region at the cochlear base, multi-tone stimuli induce a quadratic distortion product in the vibrations that suggests the presence of an offset.
View Article and Find Full Text PDFSpike conduction velocity characteristically differs between myelinated and unmyelinated axons. Here we test whether spikes of myelinated and unmyelinated paths differ in other respects by measuring rat retinal ganglion cell (RGC) spike duration in the intraretinal, unmyelinated nerve fiber layer and the extraretinal, myelinated optic nerve and optic chiasm. We find that rapid spike firing and illumination broaden spikes in intraretinal axons but not in extraretinal axons.
View Article and Find Full Text PDFStable and continuous biosensing of electroactive species in vivo has been achieved by using boron-doped diamond (BDD) electrodes owing to their outstanding electrochemical properties. However, the present problem in biosensing using BDD electrodes is how to specifically measure/detect the target molecules, including electrochemically inactive species. A possible solution is to fabricate an electrochemical aptamer-based (E-AB) sensor using a BDD electrode.
View Article and Find Full Text PDFNihon Yakurigaku Zasshi
August 2019
Continuous and real-time measurement of local concentrations of systemically administered drugs in vivo must be crucial for pharmacological studies. Nevertheless, conventional methods require considerable samples quantity and have poor sampling rates. Additionally, they cannot determine how drug kinetics correlates with target function over time.
View Article and Find Full Text PDFRepeated spike firing can transmit information at synapses and modulate spike timing, shape, and conduction velocity. These latter effects have been found to result from voltage-induced changes in ion currents and could alter the signals carried by axons. Here, we test whether Ca/calmodulin-dependent protein kinase II (CaMKII) regulates spike propagation in adult rat optic nerve.
View Article and Find Full Text PDFLight-gated ion channels and transporters have been applied to a broad array of excitable cells including neurons, cardiac myocytes, skeletal muscle cells and pancreatic β-cells in an organism to clarify their physiological and pathological roles. Nonetheless, among nonexcitable cells, only glial cells have been studied by this approach. Here, by optogenetic stimulation of a different nonexcitable cell type in the cochlea of the inner ear, we induce and control hearing loss.
View Article and Find Full Text PDFThe cochlear lateral wall-an epithelial-like tissue comprising inner and outer layers-maintains +80 mV in endolymph. This endocochlear potential supports hearing and represents the sum of all membrane potentials across apical and basolateral surfaces of both layers. The apical surfaces are governed by K equilibrium potentials.
View Article and Find Full Text PDFReal-time recording of the kinetics of systemically administered drugs in in vivo microenvironments may accelerate the development of effective medical therapies. However, conventional methods require considerable analyte quantities, have low sampling rates and do not address how drug kinetics correlate with target function over time. Here, we describe the development and application of a drug-sensing system consisting of a glass microelectrode and a microsensor composed of boron-doped diamond with a tip of around 40 μm in diameter.
View Article and Find Full Text PDFThe cochlea of the mammalian inner ear contains an endolymph that exhibits an endocochlear potential (EP) of +80 mV with a [K(+)] of 150 mM. This unusual extracellular solution is maintained by the cochlear lateral wall, a double-layered epithelial-like tissue. Acoustic stimuli allow endolymphatic K(+) to enter sensory hair cells and excite them.
View Article and Find Full Text PDFEukaryotic cells exhibit negative resting membrane potential (RMP) owing to the high K(+) permeability of the plasma membrane and the asymmetric [K(+)] between the extracellular and intracellular compartments. However, cochlear fibrocytes, which comprise the basolateral surface of a multilayer epithelial-like tissue, exhibit a RMP of +5 to +12 mV in vivo. This positive RMP is critical for the formation of an endocochlear potential (EP) of +80 mV in a K(+)-rich extracellular fluid, endolymph.
View Article and Find Full Text PDFStria vascularis of the mammalian cochlea transports K(+) to establish the electrochemical property in the endolymph crucial for hearing. This epithelial tissue also transports various small molecules. To clarify the profile of proteins participating in the transport system in the stria vascularis, membrane components purified from the stria of adult rats were analysed by liquid chromatography tandem mass spectrometry.
View Article and Find Full Text PDFLumen formation is important for morphogenesis; however, an unanswered question is whether it involves the collective migration of epithelial cells. Here, using a collagen gel overlay culture method, we show that Madin-Darby canine kidney cells migrated collectively and formed a luminal structure in a collagen gel. Immediately after the collagen gel overlay, an epithelial sheet folded from the periphery, migrated inwardly, and formed a luminal structure.
View Article and Find Full Text PDF