Chimeric antigen receptor T-cell (CAR T-cell) therapy has revolutionized the treatment of hematologic malignancies in patients with relapsed or refractory disease without other treatment options. However, only a very small proportion of patients with an indication for CAR T-cell can access the treatment. The imbalance between supply and demand is magnified in minority and vulnerable populations.
View Article and Find Full Text PDFPtychography is a lensless imaging technique that is aberration-free and capable of imaging both the amplitude and the phase of radiation reflected or transmitted from an object using iterative algorithms. Working with extreme ultraviolet (EUV) light, ptychography can provide better resolution than conventional optical microscopy and deeper penetration than scanning electron microscope. As a compact lab-scale EUV light sources, high harmonic generation meets the high coherence requirement of ptychography and gives more flexibilities in both budget and experimental time compared to synchrotrons.
View Article and Find Full Text PDFMany European sculptures and altarpieces from the Middle Ages were decorated with Zwischgold, a bilayer metal leaf with an ultra-thin gold face backed by silver. Zwischgold corrodes quickly when exposed to air, causing the surface of the artefact to darken and lose gloss. The conservation of such Zwischgold applied artefacts has been an obstinate problem.
View Article and Find Full Text PDFThe performance of functional materials is either driven or limited by nanoscopic heterogeneities distributed throughout the material's volume. To better our understanding of these materials, we need characterization tools that allow us to determine the nature and distribution of these heterogeneities in their native geometry in 3D. Here, we introduce a method based on x-ray near-edge spectroscopy, ptychographic x-ray computed nanotomography, and sparsity techniques.
View Article and Find Full Text PDFTransmission electron microscopes use electrons with wavelengths of a few picometers, potentially capable of imaging individual atoms in solids at a resolution ultimately set by the intrinsic size of an atom. However, owing to lens aberrations and multiple scattering of electrons in the sample, the image resolution is reduced by a factor of 3 to 10. By inversely solving the multiple scattering problem and overcoming the electron-probe aberrations using electron ptychography, we demonstrate an instrumental blurring of less than 20 picometers and a linear phase response in thick samples.
View Article and Find Full Text PDFX-ray linear dichroism and X-ray birefringence microscopy are yet to be fully utilized as instruments in the microstructural characterization of crystalline materials. Here, we demonstrate analyser-free X-ray linear dichroism microscopy using spectroscopic hard X-ray ptychography. First experiments enabled a spectroscopic and microstructural characterisation of polycrystalline vanadium pentoxide on the nanoscale, outside of diffraction-contrast based methods.
View Article and Find Full Text PDFThe pressing need for knowledge of the detailed wavefront properties of ultra-bright and ultra-short pulses produced by free-electron lasers has spurred the development of several complementary characterization approaches. Here a method based on ptychography is presented that can retrieve high-resolution complex-valued wavefunctions of individual pulses without strong constraints on the illumination or sample object used. The technique is demonstrated within experimental conditions suited for diffraction experiments and exploiting Kirkpatrick-Baez focusing optics.
View Article and Find Full Text PDFBoth high resolution and high precision are required to quantitatively determine the atomic structure of complex nanostructured materials. However, for conventional imaging methods in scanning transmission electron microscopy (STEM), atomic resolution with picometer precision cannot usually be achieved for weakly-scattering samples or radiation-sensitive materials, such as 2D materials. Here, we demonstrate low-dose, sub-angstrom resolution imaging with picometer precision using mixed-state electron ptychography.
View Article and Find Full Text PDFAcross all branches of science, medicine and engineering, high-resolution microscopy is required to understand functionality. Although optical methods have been developed to `defeat' the diffraction limit and produce 3D images, and electrons have proven ever more useful in creating pictures of small objects or thin sections, so far there is no substitute for X-ray microscopy in providing multiscale 3D images of objects with a single instrument and minimal labeling and preparation. A powerful technique proven to continuously access length scales from 10 nm to 10 µm is ptychographic X-ray computed tomography, which, on account of the orthogonality of the tomographic rotation axis to the illuminating beam, still has the limitation of necessitating pillar-shaped samples of small (ca 10 µm) diameter.
View Article and Find Full Text PDFOver the past decade, ptychography has been proven to be a robust tool for non-destructive high-resolution quantitative electron, X-ray and optical microscopy. It allows for quantitative reconstruction of the specimen's transmissivity, as well as recovery of the illuminating wavefront. Additionally, various algorithms have been developed to account for systematic errors and improved convergence.
View Article and Find Full Text PDFUnderstanding and control of the dynamic response of magnetic materials with a three-dimensional magnetization distribution is important both fundamentally and for technological applications. From a fundamental point of view, the internal magnetic structure and dynamics in bulk materials still need to be mapped, including the dynamic properties of topological structures such as vortices, magnetic singularities or skyrmion lattices. From a technological point of view, the response of inductive materials to magnetic fields and spin-polarized currents is essential for magnetic sensors and data storage devices.
View Article and Find Full Text PDFX-ray tomography has become an indispensable tool for studying complex 3D interior structures with high spatial resolution. Three-dimensional imaging using soft X-rays offers powerful contrast mechanisms but has seen limited success with tomography due to the restrictions imposed by the much lower energy of the probe beam. The generalized geometry of laminography, characterized by a tilted axis of rotation, provides nm-scale 3D resolution for the investigation of extended (mm range) but thin (μm to nm) samples that are well suited to soft X-ray studies.
View Article and Find Full Text PDFAs the resolution of X-ray tomography improves, the limited long-term stability and accuracy of nanoimaging tools does not allow computing artifact-free three-dimensional (3D) reconstructions without an additional step of numerical alignment of the measured projections. However, the common iterative alignment methods are significantly more computationally demanding than a simple tomographic reconstruction of the acquired volume. Here, we address this issue and present an alignment toolkit, which exploits methods with deep-subpixel accuracy combined with a multi-resolution scheme.
View Article and Find Full Text PDFReaching the full potential of X-ray nanotomography, in particular for biological samples, is limited by many factors, of which one of the most serious is radiation damage. Although sample deformation caused by radiation damage can be partly mitigated by cryogenic protection, it is still present in these conditions and, as we exemplify here using a specimen extracted from scales of the Cyphochilus beetle, it will pose a limit to the achievable imaging resolution. We demonstrate a generalized tomographic model, which optimally follows the sample morphological changes and attempts to recover the original sample structure close to the ideal, damage-free reconstruction.
View Article and Find Full Text PDFWe present a systematic study, where effects of the illumination probe design on ptychography reconstruction quality are evaluated under well-controlled conditions. The illumination probe was created using Fresnel zone-plate (FZP) optics with locally displaced zones to provide a fine control over perturbations of the illumination wavefront. We show that optimally designed wavefront modulations not only reduce bias and variance in the reconstruction of the lowest spatial frequencies but also lead to improved imaging resolution and reduction of artefacts compared to a conventional FZP.
View Article and Find Full Text PDFScanning X-ray microscopy such as X-ray ptychography requires accurate and fast positioning of samples in the X-ray beam. Sample stages often have a high mobile mass as they may carry additional mechanics or mirrors for position measurements. The high mobile mass of a piezo stage can introduce vibrations in the setup that will lead to imaging quality deterioration.
View Article and Find Full Text PDFThe search for higher performance, improved safety, and lifetime of lithium-ion batteries relies on the understanding of degradation mechanisms. Complementary to methods and studies on primary particles or crystalline structure on bulk materials, here we use spatially correlated ptychographic X-ray computed nanotomography with a 35 nm resolution and scanning X-ray diffraction microscopy with 1 μm resolution to visualize in 3D the hidden morphological and structural degradation processes in individual secondary particles of lithium-rich nickel, cobalt, and manganese oxides. From comparative examination of pristine and cycled particles, we suggest that morphological degradation could have radial dependency and secondary particle size dependency.
View Article and Find Full Text PDFPtychography is a coherent diffractive imaging method that can provide a diffraction-limited, robust reconstruction of the sample's complex transmission function without the use of high-quality optics. However, the scanning nature of conventional X-ray ptychography unavoidably requires the mechanical motion of either the illumination probe or the sample. In order to avoid overhead related to breaking and acceleration for every scan position, so-called fly-scan methods were developed.
View Article and Find Full Text PDFFor many scientific questions gaining three-dimensional insight into a specimen can provide valuable information. We here present an instrument called "tOMography Nano crYo (OMNY)," dedicated to high resolution 3D scanning x-ray microscopy at cryogenic conditions via hard X-ray ptychography. Ptychography is a lens-less imaging method requiring accurate sample positioning.
View Article and Find Full Text PDFAlthough ptychography does not require a precise knowledge of the illumination wavefront, common implementations rely upon assumptions such as accurate knowledge of the scan positions and constant illumination. Limited validity of these assumptions results in deterioration of the reconstruction quality. We present a generalized ptychography method that optimizes the reconstruction along multiple directions.
View Article and Find Full Text PDFThe soft X-ray (SXR) emission provides valuable insight into processes happening inside of high-temperature plasmas. A standard method for deriving the local emissivity profiles of the plasma from the line-of-sight integrals measured by pinhole cameras is the tomographic inversion. Such an inversion is challenging due to its ill-conditioned nature and because the reconstructed profiles depend not only on the quality of the measurements but also on the inversion algorithm used.
View Article and Find Full Text PDFPtychographic Coherent diffractive imaging (PCDI) is a significant advance in imaging allowing the measurement of the full electric field at a sample without use of any imaging optics. So far it has been confined solely to imaging of linear optical responses. In this paper we show that because of the coherence-preserving nature of nonlinear optical interactions, PCDI can be generalised to nonlinear optical imaging.
View Article and Find Full Text PDFThis note amends the list of funders in a recent Letter [Opt. Lett.41, 1317 (2016)OPLEDP0146-959210.
View Article and Find Full Text PDFHigh-harmonic generation (HHG) provides a laboratory-scale source of coherent radiation ideally suited to lensless coherent diffractive imaging (CDI) in the EUV and x-ray spectral region. Here we demonstrate transmission extreme ultraviolet (EUV) ptychography, a scanning variant of CDI, using radiation at a wavelength around 29 nm from an HHG source. Image resolution is diffraction-limited at 54 nm and fields of view up to ∼100 μm are demonstrated.
View Article and Find Full Text PDFPtychography is a scanning coherent diffractive imaging (CDI) technique that relies upon a high level of stability of the illumination during the course of an experiment. This is particularly an issue for coherent short wavelength sources, where the beam intensity is usually tightly focused on the sample in order to maximize the photon flux density on the illuminated region of the sample and thus a small change in the beam position results in a significant change in illumination of the sample. We present an improved ptychographic method that allows for limited stability of the illumination wavefront and thus significantly improve the reconstruction quality without additional prior knowledge.
View Article and Find Full Text PDF