Publications by authors named "OLIVECRONA H"

Background And Purpose: Pain in the sacroiliac joint may be caused by abnormal joint motion. Diagnosis is mainly based on clinical tests. The aims of this study were to examine whether low-dose computed tomography with provocation of the hip could detect sacroiliac joint motion, and to study whether provocation of the hip results in greater sacroiliac joint motion in the ipsilateral than in the contralateral sacroiliac joint.

View Article and Find Full Text PDF

Background: Volar locking plate fixation (VLPF) is the most common method for operative fixation of distal radius fractures (DRF). The dorsal ulnar corner (DUC) can be difficult to stabilize as the fragment is small and not exposed when using the volar approach. The purpose of this study was to study fracture fragment migration after VLPF of AO type C DRF, using a volume registration technique of paired CT scans with special focus on the DUC fragment.

View Article and Find Full Text PDF

Early implant migration is an indicator of the long-term survival/failure of implants. CT-based radio-stereometric analysis (CT-RSA) is a precise method for measuring and visualizing implant migration in vivo using image processing of CT scans. This makes the method widely applicable to orthopedic researcher.

View Article and Find Full Text PDF

Purpose: High-energy pelvic fractures are complex injuries often requiring surgical treatment. Different radiological methods exist to evaluate the reduction and healing process postoperatively but with certain limitations. The aim of this study was to evaluate Computed Tomography Micromotion Analysis (CTMA) in a clinical setting for follow-up of surgically treated pelvic fracture patients.

View Article and Find Full Text PDF

Background And Purpose: Inducible displacement CT compares 2 CTs acquired in series but with alternated rotation of the femur. This provides visual and quantitative clues as to the mechanical situation, i.e.

View Article and Find Full Text PDF

Background: Photochemical internalization (PCI) is a novel technology for light-induced enhancement of the local therapeutic effect of cancer drugs, utilizing a specially designed photosensitizing molecule (fimaporfin). The photosensitizing molecules are trapped in endosomes along with macromolecules or drugs. Photoactivation of fimaporfin disrupts the endosomal membranes so that drug molecules are released from endosomes inside cells and can reach their therapeutic target in the cell cytosol or nucleus.

View Article and Find Full Text PDF

Background And Purpose: CT micromotion analysis (CTMA) has been considered as an alternative to radiostereometry (RSA) for assessing early implant migration of orthopedic implants. We investigated the feasibility of CTMA to assess early migration and the progression of radiolucent lines in shoulder arthroplasties over 24 months using sequential low-dose CT scans.

Patients And Methods: 7 patients were included and underwent 9 primary total shoulder arthroplasties.

View Article and Find Full Text PDF

Adverse events in total hip replacement (THR) may have several origins, one being lack of precision in diagnosis and/or during surgery. This study describes the pattern and frequency of avoidable injuries in THR and the potential value of a new tool for early diagnosis of implant loosening. This retrospective study was based on all ( = 1 456) settled claims regarding THR in the Swedish National Patient Insurance database from 2010 to 2017.

View Article and Find Full Text PDF

Background and purpose - CT (computed tomography) based methods have lately been considered an alternative to radiostereometry (RSA) for assessing early implant migration. However, no study has directly compared the 2 methods in a clinical setting. We estimated the precision and effective radiation dose of a CT-based method and compared it with marker-based RSA in 10 patients with hip arthroplasty.

View Article and Find Full Text PDF

Scaphoid and lunate mobility has been suggested to be minimal during the dart-throwing motion in studies based on serial computed tomography (CT) scans and cadaver studies. This study analyzes the direct motion between the scaphoid and the lunate during the dart-throwing motion . We examined nine individuals with standard CT scans of the wrist in radial extension and ulnar flexion.

View Article and Find Full Text PDF

Background And Aims: Photochemical internalization (PCI) is a technology for inducing release of endocytosed antigens into the cell cytosol a light-induced process. Preclinical experiments have shown that PCI improves MHC class I antigen presentation, resulting in strongly enhanced CD8+ T-cell responses to polypeptide antigens. In PCI vaccination a mixture of the photosensitizing compound fimaporfin, vaccine antigens, and an adjuvant is administered intradermally followed by illumination of the vaccination site.

View Article and Find Full Text PDF

Photochemical internalization (PCI) is a technology to induce a localized, intracellular enhancement of therapeutics that are processed through endosomal pathways, including gemcitabine in malignant cells. In addition to a direct phototoxic and tumoricidal effect, PCI specifically disrupts endosomal membranes and, thereby, the compartmentalization of certain cytotoxic compounds to enhance a drug's intended intracellular target reach within the tissue treated. Non-resectable extrahepatic cholangiocarcinoma (eCCA) is a common primary tumor and gemcitabine/cisplatin chemotherapy is widely considered standard of care for it.

View Article and Find Full Text PDF

Background and purpose - Early postoperative implant migration predicts failure of joint replacements. Bone mineral density reflects bone quality and bone-graft incorporation. Implant migration and bone densitometry analysis usually require special equipment.

View Article and Find Full Text PDF

Background and purpose - Early implant migration is known to be a predictive factor of clinical loosening in total hip arthroplasty (THA). Radiostereometric analysis (RSA) is the gold standard used to measure early migration in patients. However, RSA requires costly, specialized imaging equipment and the image process is complex.

View Article and Find Full Text PDF

Background: Radiostereometric analysis (RSA) is the gold standard to measure early implant migration which is a predictive factor for implant survival.

Purpose: To validate an alternative computed tomography (CT) technique to measure implant migration in shoulder arthroplasty.

Material And Methods: A cadaver proximal humerus and a scapula, which had tantalum beads incorporated within them, were prepared to accept a short-stemmed humeral component and a two-pegged glenoid component of a commercial total shoulder arthroplasty (TSA) system.

View Article and Find Full Text PDF

Purpose: Lunocapitate arthrodesis is a motion-preserving salvage procedure for painful wrist osteoarthritis. Because the arthrodesis is limited to the capitate and the lunate, the adaptive motion of the triquetrum is theoretically maintained. We aimed to examine whether triquetral motion is sustained after lunocapitate arthrodesis.

View Article and Find Full Text PDF

This case report follows a woman who had a total hip replacement in 1992 when she was 45 years old. Six serial computed tomography (CT) examinations over a period of 13 years provided information that allowed her revision surgery to be limited to liner replacement as opposed to replacement of the entire prosthesis. Additionally, they provided data that ruled out the presence of osteolysis and indeed none was found at surgery.

View Article and Find Full Text PDF

As part of the 14-year follow-up of a prospectively randomized radiostereometry (RSA) study on uncemented cup fixation, two pairs of stereo radiographs and a CT scan of 46 hips were compared. Tantalum beads, inserted during the primary operation, were detected in the CT volume and the stereo radiographs and used to produce datasets of 3D coordinates. The limit of agreement between the combined CT and RSA datasets was calculated in the same way as the precision of the double RSA examination.

View Article and Find Full Text PDF

Background and Purpose. The gold standard for detection of implant wear and migration is currently radiostereometry (RSA). The purpose of this study is to compare a three-dimensional computed tomography technique (3D CT) to standard RSA as an alternative technique for measuring migration of acetabular cups in total hip arthroplasty.

View Article and Find Full Text PDF

Objectives: Computed tomography (CT) plays an important role in evaluating wear and periacetabular osteolysis (PAO) in total hip replacements. One concern with CT is the high radiation exposure since standard pelvic CT provides approximately 3.5 millisieverts (mSv) of radiation exposure, whereas a planar radiographic examination with three projections totals approximately 0.

View Article and Find Full Text PDF

Objective: Anakinra is approved for the treatment of RA and cryopyrin-associated periodic syndromes (CAPS). While the anakinra safety profile is well established in RA, the long-term safety profile in severe CAPS is less well documented and will therefore be discussed in this report.

Methods: A prospective, open-label, single centre, clinical cohort study was conducted at the National Institutes of Health in the USA, from 2003 to 2010, investigating the efficacy and safety of anakinra treatment for up to 5 years in 43 patients with CAPS.

View Article and Find Full Text PDF

Background: Radiostereometric analysis (RSA) is often used for evaluating implanted devices over time. Following patients who have had tantalum beads implanted as markers in conjunction with joint replacements is important for longitudinal evaluation of these patients and for those with similar implants. As doing traditional RSA imaging is exacting and limited to specialized centers, it is important to consider alternative techniques for this ongoing evaluation.

View Article and Find Full Text PDF

This study describes a 3D-CT method for analyzing facet joint motion and vertebral rotation in the lumbar spine after TDR. Ten patients were examined before and then three years after surgery, each time with two CT scans: provoked flexion and provoked extension. After 3D registration, the facet joint 3D translation and segmental vertebral 3D rotation were analyzed at the operated level (L5-S1) and adjacent level (L4-L5).

View Article and Find Full Text PDF

Object: Artificial disc replacement (ADR) devices are unlike implants used in cervical fusion in that they are continuously exposed to stress not only within the implant site but also at their site of attachment to the adjacent vertebra. An imaging technique with higher accuracy than plain radiography and with the possibility of 3D visualization would provide more detailed information about the motion quality and stability of the implant in relation to the vertebrae. Such high-accuracy studies have previously been conducted with radiostereometric analysis (RSA), which requires implantation of tantalum markers in the adjacent vertebrae.

View Article and Find Full Text PDF