Bioresour Technol
August 2024
Limited information is available on the removal of per- and polyfluoroalkyl substances (PFAS) in anaerobic digestion (AD). Τhe fate of six PFAS was studied in thermophilic bioreactors in the presence of granular activated carbon (GAC) and voltage application. Reactors with GAC exhibited lower concentrations of volatile fatty acids and higher methane production compared to those with and without the application of voltage.
View Article and Find Full Text PDFThe existence of the artificial sweetener acesulfame (ACE) in quantities of significance can negatively impact water quality, and its consumption has been associated with deleterious health effects. The present investigation explores the efficacy of heat-activated sodium persulfate (SPS) for eliminating ACE. The complete degradation of 0.
View Article and Find Full Text PDFAn integrated lab-scale wastewater treatment system consisting of an anaerobic Moving Bed Biofilm Reactor (AnMBBR) and an aerobic Membrane Bioreactor (AeMBR) in series was used to study the removal and fate of pharmaceuticals during wastewater treatment. Continuous-flow experiments were conducted applying different temperatures to the AnMBBR (Phase A: 35 °C; Phase B: 20 °C), while batch experiments were performed for calculating sorption and biotransformation kinetics. The total removal of major pollutants and target pharmaceuticals was not affected by the temperature of the AnMBBR.
View Article and Find Full Text PDFSonochemical oxidation was employed for the degradation of the drug dexamethasone (Dex). The oxidation at 20 kHz followed pseudo-first-order kinetics and increased with applied ultrasound power density. Acoustic cavitation at 71 W/L was able to eliminate 500 μg/L of dexamethasone from ultrapure water at inherent pH in less than 60 min.
View Article and Find Full Text PDFIn this article we applied drug consumption approach and chemical analysis in parallel to investigate the concentrations of a large number of pharmaceuticals in different streams of a General Hospital. Drugs consumption data was collected during two periods (Period 1, 2) and the predicted environmental concentrations (PECs) were estimated for the wastewater of a building housing specific medical services (Point A) and for the entire hospital (Point B). Hospital wastewater samples (HWW) samples were also collected from these points and periods and the measured environmental concentrations (MEC) were determined using UHPLC-ESI-QTOF-MS/MS.
View Article and Find Full Text PDF