Purpose: to present and validate a method for modeling three-dimensional positron emission (PE) activity distributions induced by proton beam irradiation for PET/CT delivery verification studies in homogeneous media.
Methods: the method relies on modeling the 3D proton flux distribution by combining the analytical expression for the depth reduction of proton flux with the empirically obtained lateral distribution. The latter is extracted from the corresponding dose distribution under the assumption that the projectile energy is nearly constant in the lateral plane.
Technol Cancer Res Treat
October 2012
Linear energy transfer (LET) of clinical proton beams is an important parameter influencing the biological effects of radiation. This work demonstrates LET-induced response enhancement in novel formulations of polymer gel dosimeters, potentially useful for LET mapping of clinical proton beams. A series of four polymer gel dosimeters (labeled A through D), prepared based on the BANG3-Pro2 formulation, but with varying concentrations of polymerization modifiers, were irradiated by a clinical proton beam with a spread out Bragg peak modulation (SOBP) and read out using the OCTOPUS-IQ optical CT scanner.
View Article and Find Full Text PDFOrgan motion in proton therapy affects treatment dose distribution during both double-scattering (DS) and uniform-scanning (US) deliveries. We investigated the dosimetric impact of target motion using three-dimensional polymer gel dosimeters and a programmable motion platform. A simple one-beam treatment plan with 16 cm range and 6 cm modulation was generated from the treatment planning system (TPS) in both the DS and US modes.
View Article and Find Full Text PDFPurpose: This work demonstrates a novel application of BANG3-Pro2 polymer gel dosimeter as a dosimetric phantom able to accurately capture both dose and induced activity.
Methods: BANG3-Pro2 dosimeters were irradiated with a clinical proton beam using an unmodulated beam and a spread-out Bragg peak (SOBP) modulation, the latter with a Lucite compensator to introduce a range offset in one quadrant of the circular field. The dosimeters were imaged in a nearby positron emission tomography/computed tomography (PET/CT) unit starting within 5 min of beam-off.
Technol Cancer Res Treat
December 2011
A spatial resolution investigation of the OCTOPUSTM-IQ scanner in combination with the new BANG3-Pro2(r) polymer gel was performed by scanning a high-contrast needle phantom. The phantom contained five thin needles (0.3_mm diameter) embedded in gel positioned in different patterns: needles were inserted (a) at 45° angle from the center of the gel container, and (b) vertically along the gel axis.
View Article and Find Full Text PDF