Impedance cardiography (ICG) is a low-cost, non-invasive technique that enables the clinical assessment of haemodynamic parameters, such as cardiac output and stroke volume (SV). Conventional ICG recordings are taken from the patient's thorax. However, access to ICG vital signs from the upper-arm brachial artery (as an associated surrogate) can enable user-convenient wearable armband sensor devices to provide an attractive option for gathering ICG trend-based indicators of general health, which offers particular advantages in ambulatory long-term monitoring settings.
View Article and Find Full Text PDFThere are highly conflicting data on relative frequency (2-32%), prognosis, and management of pT1b-gallbladder carcinoma (GBC), with 5-year survival ranging from > 90% in East/Chile where cholecystectomy is regarded as curative, versus < 50% in the West, with radical operations post-cholecystectomy being recommended by guidelines. A total of 473 in situ and invasive extensively sampled GBCs from the USA (n = 225) and Chile (n = 248) were re-evaluated histopathologically per Western invasiveness criteria. 349 had invasive carcinoma, and only 24 were pT1.
View Article and Find Full Text PDFThis article presents the development of a power loss emulation (PLE) system device to study and find ways of mitigating skin tissue heating effects in transcutaneous energy transmission systems (TETS) for existing and next generation left ventricular assist devices (LVADs). Skin thermal profile measurements were made using the PLE system prototype and also separately with a TETS in a porcine model. Subsequent data analysis and separate computer modelling studies permit understanding of the contribution of tissue blood perfusion towards cooling of the subcutaneous tissue around the electromagnetic coupling area.
View Article and Find Full Text PDFSudden cardiac death (SCD) risk can be reduced by early detection of short-lived and transient cardiac arrhythmias using long-term electrocardiographic (ECG) monitoring. Early detection of ventricular arrhythmias can reduce the risk of SCD by allowing appropriate interventions. Long-term continuous ECG monitoring, using a non-invasive armband-based wearable device is an appealing solution for detecting early heart rhythm abnormalities.
View Article and Find Full Text PDFThe use of wearable dry sensors for recording long term ECG signals is a requirement for certain studies of heart rhythm. Knowledge of the skin-electrode electrical performance of dry electrodes is necessary when seeking to improve various processing stages for signal quality enhancement. In this paper, methods for the assessment of dry skin-electrode impedance (Z) and its modelling are presented.
View Article and Find Full Text PDF