: Radiography is an essential and low-cost diagnostic method in pulmonary medicine that is used for the early detection and monitoring of lung diseases. An adequate and consistent image quality (IQ) is crucial to ensure accurate diagnosis and effective patient management. This pilot study evaluates the feasibility and effectiveness of the International Atomic Energy Agency (IAEA)'s remote and automated quality control (QC) methodology, which has been tested in multiple imaging centers.
View Article and Find Full Text PDFPhys Eng Sci Med
September 2024
This article documents the work conducted in implementing the IAEA non-agreement TC regional RAS6088 project "Strengthening Education and Training Programmes for Medical Physics". Necessary information on the project was collected from the project counterparts via emails for a period of one month, starting from 21st September 2023, and verified at the Final Regional Coordination Meeting in Bangkok, Thailand from 30th October 2023 to 3rd November 2023. Sixty-three participants were trained in 5 Regional Training Courses (RTCs), with 48%, 32% and 20% in radiation therapy, diagnostic radiology, and nuclear medicine, respectively.
View Article and Find Full Text PDF: Total knee arthroplasty (TKA) has become the treatment of choice for advanced osteoarthritis. The aim of this paper was to show the possibilities of optimizing the Perth CT protocol, which is highly effective for preoperative planning and postoperative assessment of alignment. : The cross-sectional study comprised 16 patients for preoperative planning or postoperative evaluation of TKA.
View Article and Find Full Text PDFThe purpose of this work is to assess accuracy and compare the performance of radionuclide calibrators (RNCs) used in nuclear medicine departments in Serbia. Testing of the RNCs included verification of measurement accuracy, as well as analysis of routinely used quality control protocols, by using the certified radioactivity standards (Co, Cs). RNCs performances were assessed with Tc through comparison of reference value for radionuclide activity and RNC measurements.
View Article and Find Full Text PDFPurpose: The purpose of this work is to provide a comprehensive analysis of uncertainties associated with the use of software solutions utilizing DICOM RDSRs for skin dose assessment in the interventional fluoroscopic environment.
Methods And Results: Three different scenarios have been defined for determining the overall uncertainty, each with a specific assumption on the maximum deviations of factors affecting the calculated dose. Relative expanded uncertainty has been calculated using two approaches: the law of propagation of uncertainty and the propagation of distributions based on the Monte Carlo method.