Publications by authors named "Nuray Attar"

Objective: The aim of this study was to compare the clinical performances of two low-shrinkage composite resins (silorane-based and methacrylate-based) in class I cavities prepared by Er,Cr:YSGG laser or conventional diamond bur over 60 months.

Materials And Method: Eighteen patients with four similar-sized occlusal lesions in molar teeth were included to the study. A total of 72 class I cavities were prepared either by Er,Cr:YSGG laser or conventional diamond bur.

View Article and Find Full Text PDF

This study evaluated the shear bond strengths of orthodontic brackets bonded to human premolars using five different combinations of flowable composites and one-step self-etching adhesives (n=12): (1) Adper Easy Bond+Filtek Supreme XT Flow; (2) Futurabond NR+Grandio Flow; (3) Clearfil S3 Bond+Clearfil Majesty Flow; (4) AdheSE One+Tetric EvoFlow; and (5) Transbond Plus Self Etching Primer+Transbond XT Light Cure Adhesive. After shear bond strength testing, adhesive remnant index (ARI) scores were given according to the amount of adhesive and resin remaining on the brackets. On shear bond strength, there were no statistically significant differences between Groups 2 and 4 and between Groups 3 and 5 (p>0.

View Article and Find Full Text PDF

Objective: The aim of this study was to evaluate the microleakage of different nano-restorative materials in Class V cavities prepared by Er:YAG laser and bur preparation.

Materials And Methods: Class V cavities were prepared on the buccal and lingual surfaces of 72 premolars by Er:YAG laser or bur. The occlusal margins were in enamel and the cervical margins were in cementum.

View Article and Find Full Text PDF

The purpose of this study was to investigate shear bond strength (SBS) between a light-curing nano-ionomer restorative and enamel or dentin after acid etching, after erbium:yttrium-aluminum-garnet (Er:YAG) laser etching, or after combined treatment. Forty third molars were selected, the crowns were sectioned, and 80 tooth slabs were obtained. The specimens were assigned to two groups, which were divided into four subgroups(n = 10).

View Article and Find Full Text PDF

The aim of this study was to evaluate the microleakage of all-in-one self-etch adhesives and their respective nanocomposites in class V cavities prepared by erbium:yttrium-aluminum-garnet (Er:YAG) laser and bur. Class V cavities were prepared on both buccal and lingual surfaces of 72 premolars by Er:YAG laser or bur and divided into six groups (n = 24). The occlusal margins were enamel and the cervical margins were cementum.

View Article and Find Full Text PDF

The purpose of this study was to investigate the influence of one-step polishing systems on the surface roughness of different flowable composites and a microhybrid composite. A total of 120 disks were fabricated and divided into six groups according to the different composite restorative materials tested (n = 20). Each group was further divided into four subgroups according to the polishing system (n = 5).

View Article and Find Full Text PDF

Objective: The aim of this study was to evaluate the microleakage of composite resin restorations using two different dentine adhesive systems prepared with a diamond instrument and different parameters of Er:YAG laser irradiation.

Background Data: Information on this topic with regard to preparing class V cavities with different parameters of Er:YAG laser irradiation and adhesive systems is scarce.

Materials And Methods: Two hundred class V cavities were assigned to ten groups (n = 20 each): group 1: Er:YAG laser (5 Hz, 600 mJ) + phosphoric acid (PA) + Adper Single Bond 2 (ASB2); group 2: Er:YAG laser (10 Hz, 300 mJ) + PA + ASB2; group 3: Er:YAG laser (15 Hz, 200 mJ) + PA + ASB2; group 4: Er:YAG laser (20 Hz, 150 mJ) + PA + ASB2; group 5: diamond instrument + PA + ASB2; group 6: Er:YAG laser (5 Hz, 600 mJ) + Adper Prompt L-Pop (APLP); group 7: Er:YAG laser (10 Hz, 300 mJ) + APLP; group 8: Er:YAG laser (15 Hz, 200 mJ) + APLP; group 9: Er:YAG laser (20 Hz, 150 mJ) + APLP; and group 10: diamond instrument + APLP.

View Article and Find Full Text PDF

Aim: The aim of this in vitro study was to investigate the cervical microleakage and internal voids of nanocomposites comparing them with a hybrid composite in Class II restorations with the margins located coronal and apical to the cementoenamel junction (CEJ).

Methods And Materials: Standardized MOD cavities (one cervical margin located in dentin, one in enamel) were prepared in 40 extracted human molars and divided into four groups according to the composite used to restore them (n=10/group). Group 1: Adper Single Bond2/Filtek Supreme XT; Group 2: Excite/Tetric EvoCeram; Group 3: Prime & BondNT/Ceram X; and Group 4 (control) Adper Single Bond2/Filtek Z250.

View Article and Find Full Text PDF

Aim: The aim of this study was to evaluate the antibacterial effects of different one-step and two-step self-etching primer/adhesives on Streptococcus mutans (S. mutans), Lactobacillus casei (L. casei), and Lactobacillus acidophilus (L.

View Article and Find Full Text PDF

Objectives: This in vitro study evaluated the surface roughness and microhardness of nanocomposites that contain nanoparticles and a microhybrid composite finished and polished with two different one-step polishing systems and a conventional multi-step polishing system.

Methods And Materials: The materials evaluated were Filtek Supreme XT, Grandio, Ceram X, Aelite Aesthetic Enamel, Tetric EvoCeram and Filtek Z250. A total of 240 specimens (10-mm in diameter, 2 mm thick) were fabricated for both tests (n=120 each test) in a plexiglass mold covered with a Mylar strip.

View Article and Find Full Text PDF

Objective: The aim of this study was to compare the shear bond strength (SBS) of orthodontic brackets after acid etching, laser ablation, self-etching primer application, and combined treatments.

Methods: One hundred defect-free premolars were randomly assigned to five groups. The teeth received the following treatments: group 1: phosphoric acid + Transbond XT primer; group 2: Transbond Plus Self-Etching Primer (TPSEP); group 3: Er:YAG laser ablation + Transbond XT primer; group 4: Er:YAG laser ablation + phosphoric acid + Transbond XT primer; and group 5: Er:YAG laser ablation + TPSEP.

View Article and Find Full Text PDF

This study evaluated the two-year clinical performance of one microhybrid composite and three different types of flowable resin materials in non-carious cervical lesions. A total of 252 noncarious cervical lesions were restored in 37 patients (12 male, 25 female) with Admira Flow, Dyract Flow, Filtek Flow and Filtek Z250, according to manufacturers' instructions. All the restorations were placed by one operator, and two other examiners evaluated the restorations clinically within one week after placement and after 6, 12, 18 and 24 months, using modified USPHS criteria.

View Article and Find Full Text PDF

Aim: The purpose of this study was to investigate the effect of light-emitting diode (LED) light curing units (LCUs) compared with halogen LCUs on the shear bond strength (SBS) of one nanofill composite (Filtek Supreme) and one microhibrid composite (Artemis) with self-etch adhesives.

Methods And Materials: The buccal surfaces of 60 non-carious extracted human molars were flattened to expose dentin and, subsequently, polished for 60 seconds with 600-grit wet silicon carbide abrasive paper. Specimens were assigned into six groups (n=10) according to composite material, self-etch adhesive, and curing light used as follows: Group 1: Adper Prompt L-Pop (AP) and Filtek Supreme (FS) using an Elipar Free Light (EFL); Group 2: AP and FS using an Elipar Free Light 2 (EFL2); Group 3: AP and FS using a Hilux Expert (HE) light, Group 4: AdheSE (AS)+Artemis (AR) using an EFL; Group 5: AS+AR using an EFL2; and Group 6: AS+AR using a HE light.

View Article and Find Full Text PDF

Purpose: The aim of this study was to determine the influence of four flowable composite linings on marginal microleakage and internal voids in Class II composite restorations with the margins above the cementoenamel junction (CEJ).

Materials And Methods: Class II cavities were randomly divided into 8 groups (n = 10). Group 1: One Step Plus/Aelite LS Packable; group 2: One Step Plus/Aelite Flow/Aelite LS Packable; group 3: Comfort Bond/Solitaire 2; group 4: Comfort Bond/Flowline/Solitaire 2; group 5: Solobond M/Grandio; group 6: Solobond M/Grandio Flow/Grandio; group 7: Admira Bond/Admira; Group 8: Admira bond/Admira Flow/Admira.

View Article and Find Full Text PDF

Objective: To assess and compare the effects of one- and two-step self-etching primer and adhesive with conventional acid-etching and bonding system on the shear bond strength of orthodontic brackets.

Materials And Methods: The one-step self-etching primer and adhesive used was Clearfil tri-S bond, the two-step fluoride-releasing antibacterial self-etching primer and adhesive was Clearfil Protect Bond, and the fluoride-releasing conventional acid-etching and bonding system was Kurasper F Bond. Brackets were bonded to defect-free human premolars (n = 14 per group) according to each manufacturer's recommendations by using light-cured bracket adhesive Kurasper F Paste with a light-emitting diode of a light-curing unit.

View Article and Find Full Text PDF

Aim: The disadvantages of light cured composite resin materials with respect to microleakage are predominantly a result of polymerization shrinkage upon curing. It has been shown curing methods play a significant role in polymerization shrinkage of light-cured composite resins. The purpose of this study was to investigate the effect of light-emitting diode (LED) light curing units (LCUs) compared with a halogen LCU on microleakage of three different flowable composites using self-etch adhesives.

View Article and Find Full Text PDF

Aims: The aims of this study were to evaluate the effect of various finishing and polishing procedures on the surface roughness of six different composite resin materials (Artemis Enamel, TPH Spectrum, Filtek A-110, Filtek Supreme Enamel, Solitaire 2, and Filtek P-60) as well as to evaluate the effectiveness of the surface sealant application (BisCover) on the surface roughness after finishing and polishing procedures of tested composites.

Methods And Materials: Specimens (n=168) measuring 5 mm in diameter x 2 mm in thickness were fabricated in a plexiglass well covered with a Mylar strip using six composite resins. A control group of seven specimens of each material received no polishing after being cured under the Mylar strip.

View Article and Find Full Text PDF

This study determined the radiopacity of 21 commercially available direct esthetic restorative materials with reference to an aluminum step wedge and an equivalent thickness of enamel and dentin. A total of 168 samples measuring 6 mm in diameter and 1 mm in thickness, with eight samples of each material, were prepared from restorative materials. Enamel and dentin samples 1-mm thick were also prepared by longitudinally sectioning eight extracted human permanent molars using a microslicing machine.

View Article and Find Full Text PDF

Objective: This study was undertaken to characterize 9 currently available proprietary flowable composites with respect to key properties of flow, flexural strength, stiffness (modulus of elasticity) and radiopacity.

Methods: Seven proprietary flowable composites (Aelite Flo, Filtek Flow, Heliomolar Flow, PermaFlo, Revolution Formula 2, Tetric Flow, Wave) and 2 flowable compomers (Compoglass Flow, Dyract Flow) were evaluated. A universal hybrid composite (Filtek Z250) and a restorative compomer (Dyract AP) were used as controls.

View Article and Find Full Text PDF

Many fluoride-releasing dental materials are being sold on the basis of their cariostatic properties. However, the amount fluoride release of these materials is still uncertain. This study investigated the fluoride release and uptake characteristics of four flowable resin composites (Heliomolar Flow, Tetric Flow, Wave, Perma Flo), one flowable compomer (Dyract flow), one conventional glass ionomer cement mixed with two different powder/liquid ratios (ChemFlex Syringeable and ChemFlex Condensable), one packable resin composite (SureFil), one ion-releasing composite (Ariston pHc) and one resin-modified glass ionomer cement (Vitremer).

View Article and Find Full Text PDF

This study evaluated the microleakage of a flowable polyacid-modified resin composite used as a fissure sealant on air-abraded teeth in comparison to a resin-based fluoride sealant. Sixty extracted human third molars were divided into six subgroups (n = 10) under two main groups (fissure sealant materials). The occlusal surfaces of the teeth were air-abraded at 80 psi using 50 microm particles of aluminum oxide for 30 seconds, followed by rinsing and drying.

View Article and Find Full Text PDF

Statement Of Problem: New luting agents, particularly with adhesive capability, are being introduced in an attempt to improve clinical success. Independent studies of basic comparative data are necessary to characterize these materials in relation to mechanical and physical properties.

Purpose: The purpose of this study was to compare the flexural strength, modulus of elasticity, and radiopacity and pH of representatives of 5 types (categories) of luting agents.

View Article and Find Full Text PDF

Dental restorations fail for a variety of reasons. Secondary caries is one of the primary causes of failure of dental restorations. One method for reducing frequency and severity of this problem is the use of fluoride containing restorative materials.

View Article and Find Full Text PDF