Publications by authors named "Nuanlaor Ratanawimarnwong"

Melamine has been intentionally added into food products to increase the protein count at less cost, especially in dairy products for infant resulting in serious adverse effects on health of consumers. Therefore, this study aimed to develop a method to quantify melamine in dairy products based on the change of fluorescent properties of carbon dots (CDs) as sensing probe. CDs with green-fluorescent emission were synthesized from citric acid and urea under microwave irradiation.

View Article and Find Full Text PDF
Article Synopsis
  • The study introduces a transparent 'Cross Injection Analysis' (CIA) platform for measuring chemiluminescence (CL) in a streamlined flow system.
  • It successfully analyzes Co(II) and paracetamol, demonstrating a calibration range of 0.002 to 0.025 mg/L for Co(II) and 10 to 200 mg/L for paracetamol.
  • The system supports high sample throughput at 60 samples per hour with a precision of ≤4.2% RSD and minimal reagent usage of about 170 µL per analysis.
View Article and Find Full Text PDF

This work presents a microfluidic paper-based analytical device (μPAD) for the determination of sucrose using the Benedict's test. An asymmetric dumbbell-shaped hydrophobic barrier was produced by rubber stamping the barrier pattern onto a laboratory filter paper. Hydrochloric acid and solution containing sucrose were successively deposited onto the sample reservoir of the μPAD attached to a glass slide.

View Article and Find Full Text PDF

This work presents two simple methods for estimating the firing distance from the gunshot residues (GSRs) on fabric targets. Four types of fabric targets, namely twill weave denim cotton-polyester (80/20), jersey knitting 100% cotton, plain weave cotton-polyester (80/20) and plain weave cotton-polyester (60/40), were employed. The firing tests were carried out using these white fabrics as targets at distances of 5-100 cm, respectively.

View Article and Find Full Text PDF

A new design of a membraneless vaporization (MBL-VP) unit coupled with a specific flow system is presented for the determination of arsenic at trace levels using a hydride generation process. The MBL-VP unit contains two concentric conical reservoirs, with the outer cone selected as the donor reservoir. The volume of the outer donor reservoir is thereby greater than the acceptor volume, necessary for holding sufficient sample and reagents for the generation of arsine gas by reaction between As(iii) and sodium borohydride under acidic conditions.

View Article and Find Full Text PDF

This work presents a novel development that exploits the concept of in-situ gas-separation together with a specific enzymatic colorimetric detection to produce a portable biosensor called "Blood Alcohol Micro-pad" for direct quantitation of ethanol in whole blood. The thin square device (25 mm × 25 mm × 1.8 mm) comprises two layers of patterned filter paper held together with a double-sided mounting tape with an 8-mm circular hole (the headspace).

View Article and Find Full Text PDF

The effect of solvent composition on the uv-visible spectrum of methyl orange was investigated for application to the quantitative determination of ethanol. At fixed pH, there was a hypsochromic shift of the absorbance band of methyl orange with increasing ethanol concentration. Using acetate buffer at pH 3.

View Article and Find Full Text PDF

This work presents the use of polyvinyl chloride (PVC) fabric ink, commonly employed for screening t-shirts, as new and versatile material for printing hydrophobic barrier on paper substrate for microfluidic paper-based analytical devices (μPADs). Low-cost, screen-printing apparatus (e.g.

View Article and Find Full Text PDF

A flow injection analysis system (FIA) for the simultaneous determination of salinity, carbonate and ammoniacal nitrogen has been developed and reported in this paper. FIA incorporating membrane units was used, not only for the separation of the gaseous carbon dioxide and ammonia, but also for on-line dilution in the salinity measurement. The sample was injected via a 10-port valve with two sample loops.

View Article and Find Full Text PDF

A new design of membraneless gas-diffusion unit with dual acceptor channels for separation, collection and simultaneous determination of two volatile analytes in liquid sample is presented. The unit is comprised of three parallel channels in a closed module. A sample is aspirated into the central channel and two kinds of reagents are introduced into the other two channels.

View Article and Find Full Text PDF

A microfluidic method with front-face fluorometric detection was developed for the determination of total inorganic iodine in drinking water. A polydimethylsiloxane (PDMS) microfluidic device was employed in conjunction with the Sandell-Kolthoff reaction, in which iodide catalyzed the redox reaction between Ce(IV) and As(III). Direct alignment of an optical fiber attached to a spectrofluorometer was used as a convenient detector for remote front-face fluorometric detection.

View Article and Find Full Text PDF

A low-cost and user-friendly microfluidic paper-based analytical device (μPAD) was developed for identification of bullet hole from gunshot residue (GSR) on cotton fabric target. The device (25 × 82 mm) is made of filter paper with a printed pattern consisting of a circular sample loading reservoir (6 mm i.d.

View Article and Find Full Text PDF

Use of membraneless vaporization (MBL-VP) unit with two cone-shaped reservoirs is presented for on-line separation and detection of non-volatile species. A flow system comprising two sets of MBL-VP units with a single in-house capacitively coupled contactless conductivity detector (C4D) was developed for dual determination of ammonium and sulfide ions. Using the continuous-flow section, two zones (280μL) of a sample, either mixed with sodium hydroxide (for ammonium) or hydrochloric acid (for sulfide), are separately delivered into the donor reservoir of the MBL-VP units.

View Article and Find Full Text PDF

This work presents new chemical sensing devices called "membraneless gas-separation microfluidic paper-based analytical devices" (MBL-GS μPADs). MBL-GS μPADs were designed to make fabrication of the devices simple and user-friendly. MBL-GS μPADs offer direct quantitative analysis of volatile and nonvolatile compounds.

View Article and Find Full Text PDF

An automated stopped-in-loop flow analysis (SILFA) system is proposed for the successive catalytic determination of vanadium and iron. The determination of vanadium was based on the p-anisidine oxidation by potassium bromate in the presence of Tiron as an activator to form a reddish dye, which has an absorption maximum at 510 nm. The selectivity of the vanadium determination was greatly improved by adding diphosphate as a masking agent of iron.

View Article and Find Full Text PDF

This work presents the first flow system for direct analysis of iodide and creatinine suitable for screening of human urine samples. The system had a mini-column packed with strong anion exchange resin for on-line extraction of iodide. After injection of a sample on the column the unretained urine sample was analyzed for creatinine in one section of the flow system using the Jaffe's reaction with spectrometric detection at 520 nm.

View Article and Find Full Text PDF

This work presents the simultaneous determination of sucrose and phosphate by using sequential injection (SI) system with a low cost paired emitter-detector diode (PEDD) light sensor. The PEDD uses two 890 nm LEDs. Measurement of sucrose in Brix unit was carried out based on the detection of light refraction occurring at the liquid interface (the schlieren effect) between the sucrose solution and water.

View Article and Find Full Text PDF

This work presents the development of a new design for a membraneless vaporization (MBL-VP) unit, called dual chamber MBL-VP for measurement of volatile compounds. With this unit, exact volumes of sample and reagent are introduced into their respective cone-shaped chambers from the base of the cones. Diffusion of volatile analyte then takes place.

View Article and Find Full Text PDF

A new four-channel simultaneous injection effective mixing flow analysis (SIEMA) system has been assembled for the determination of urinary albumin. The SIEMA system consisted of a syringe pump, two 5-way cross connectors, four holding coils, five 3-way solenoid valves, a 50-cm long mixing coil and a spectrophotometer. Tetrabromophenol blue anion (TBPB) in Triton X-100 micelle reacted with albumin at pH 3.

View Article and Find Full Text PDF

This work proposes a flow system suitable for the rapid screening of formaldehyde contaminated in food. The system is based on the concept of a flow analyzer with a Hantzsch reaction. An operating procedure was developed for multiple tasking and high sample throughput.

View Article and Find Full Text PDF