Rationale: The benefit from applying suction during endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is unclear.
Background: The purpose of this study was to evaluate the impact of applying suction during EBUS-TBNA of lymph nodes (LN) on the diagnostic yield and specimen quality of EBUS-TBNA smears and cellblocks.
Methods: We conducted a randomized blinded cross-over trial comparing the diagnostic yield and quality of EBUS-TBNA samples obtained with suction (S+) and without suction (S-) from suspected malignant mediastinal LN.