Publications by authors named "Noti F"

Article Synopsis
  • - The study compared the effects of dexmedetomidine and propofol on heart function in patients undergoing atrial fibrillation ablation, focusing on how each sedative impacts sinus node function and atrioventricular (AV) conduction.
  • - A total of 160 patients were enrolled, with findings indicating that patients given dexmedetomidine experienced slower sinus rates and prolonged AV conduction times compared to those given propofol.
  • - Despite these differences, both sedatives did not significantly affect certain aspects of heart conduction, such as infrahissian AV conduction and ventricular repolarization, and arrhythmia occurrence was similar across both groups.
View Article and Find Full Text PDF

Background: Pulsed-field ablation (PFA) is a novel nonthermal ablation technology. Its potential value for repeat procedures after unsuccessful thermal ablation for atrial fibrillation has not been assessed.

Objective: The purpose of this study was to summarize our initial experience with patients undergoing repeat procedures using PFA.

View Article and Find Full Text PDF

Aims: Pacemaker (PM) patients may require a subsequent upgrade to an implantable cardioverter defibrillator (ICD). Limited data exists on this patient population. We sought to characterize this population, to assess predictors for ICD upgrade, and to report the outcome.

View Article and Find Full Text PDF

Background: Recurrence of paroxysmal atrial fibrillation (AF) following pulmonary vein isolation (PVI) is presumably caused by pulmonary vein (PV) reconnections. However, there is little data available on the durability of PVI and incidence of arrhythmia recurrence in patients with persistent AF.

Objectives: The purpose of this study was to evaluate the lesion durability by means of an a priori planned remapping procedure in patients with persistent AF undergoing CLOSE-guided PVI.

View Article and Find Full Text PDF

Background: Pulsed-field ablation (PFA) has shown promising data in terms of safety and procedural efficiency for pulmonary vein isolation (PVI), with similar long-term outcomes compared to radiofrequency ablation (RFA) and cryoballoon ablation (CBA) in patients with paroxysmal atrial fibrillation (AF).

Objective: The purpose of this study was to compare the procedural and long-term outcomes in patients with persistent AF undergoing PVI using PFA, CBA, or RFA.

Methods: Consecutive patients with persistent AF undergoing first PVI with PFA, CBA, or RFA were included.

View Article and Find Full Text PDF

Aims: Pulmonary vein isolation (PVI) is increasingly performed in patients with atrial fibrillation (AF). Both AF phenotype and left atrial (LA) volume have been shown to influence ablation outcome. The inter-relationship of the two is incompletely understood.

View Article and Find Full Text PDF

Aims Of The Study: To assess glucose levels in adults with diabetes at a Swiss tertiary hospital when transitioning from insulin delivery with a sensor-augmented pump with (predictive) low-glucose suspend ([P]LGS) to a hybrid-closed loop (HCL) and from a HCL to an advanced hybrid-closed loop (AHCL).

Methods: Continuous glucose monitoring data for 44 adults with type 1 diabetes transitioning from (P)LGS to hybrid-closed loop and from hybrid-closed loop to advanced hybrid-closed loop were analysed, including the percentage of time spent within, below, and above glucose ranges. In addition, a subgroup analysis (n = 14) of individuals undergoing both transitions was performed.

View Article and Find Full Text PDF
Article Synopsis
  • Leadless pacemakers (LPs) for VDD pacing rely on mechanical sensing of atrial contraction, which is less reliable than electrical sensing.
  • This study analyzed P-wave amplitudes from preoperative ECGs to predict mechanical sensing in patients undergoing LP implantation.
  • Findings showed that specific P-wave amplitudes correlate with mechanical contraction signals, indicating a potential method to enhance atrial-synchronous pacing success.
View Article and Find Full Text PDF

Background: Screening for atrial fibrillation (AF) may reveal incidental arrhythmias of relevance. The aim of this study was to describe incidental arrhythmias detected during screening for AF in the STAR-FIB (Predicting SilenT AtRial FIBrillation in Patients at High Thrombembolic Risk) cohort study.

Methods And Results: In the STAR-FIB cohort study, we screened hospitalized patients for AF with 3 repeat 7-day Holter ECGs.

View Article and Find Full Text PDF

Aims: The left atrial posterior wall is a potential ablation target in patients with recurrent atrial fibrillation despite durable pulmonary vein isolation or in patients with roof-dependent atrial tachycardia (AT). Pulsed-field ablation (PFA) offers efficient and safe posterior wall ablation (PWA), but available data are scarce.

Methods And Results: Consecutive patients undergoing PWA using PFA were included.

View Article and Find Full Text PDF

Objectives: Epicardial adipose tissue (EAT) remodeling is associated with atrial fibrillation (AF). Left atrial (LA) EAT dispersion on cardiac CT is a non-invasive imaging biomarker reflecting EAT heterogeneity. We aimed to investigate the association of LA EAT dispersion with AF recurrence after pulmonary vein isolation (PVI).

View Article and Find Full Text PDF

Aims: Implantation of an implantable cardiac monitor (ICM) is a simple procedure, but adds significant and increasing workload to the arrhythmia service. In 2020, we established a nurse-led ICM implantation service. We aimed to analyse patient satisfaction, adverse events during implant, and ICM re-interventions with nurse-led ICM implantation (N-Implant) compared to physician-led ICM implantation (P-Implant).

View Article and Find Full Text PDF

Background: Pulsed-field ablation (PFA) has shown favourable data in terms of safety and procedural efficiency for pulmonary vein isolation (PVI). We sought to compare procedural and 1-year follow-up data of patients with paroxysmal atrial fibrillation (AF) undergoing PVI using PFA, cryoballoon ablation (CBA) and radiofrequency ablation (RFA).

Methods: Consecutive patients with paroxysmal AF undergoing a first PVI with PFA at our institution were included.

View Article and Find Full Text PDF

Background: Device patients may require upgrade interventions from simpler to more complex cardiac implantable electronic devices. Prior to upgrading interventions, clinicians need to balance the risks and benefits of transvenous lead extraction (TLE), additional lead implantation or lead abandonment. However, evidence on procedural outcomes of TLE at the time of device upgrade is scarce.

View Article and Find Full Text PDF

Background: Prediction of the chamber of origin in patients with outflow tract ventricular arrhythmias (OTVA) remains challenging. A clinical risk score based on age, sex and presence of hypertension was associated with a left ventricular outflow tract (LVOT) origin. We aimed to validate this clinical score to predict an LVOT origin in patients with OTVA.

View Article and Find Full Text PDF

Background: A novel multipolar pulsed-field ablation (PFA) catheter has recently been introduced for pulmonary vein isolation (PVI). Pre-market data showed high rates for PVI-durability during mandatory remapping studies.

Objective: To present post-market data in patients with recurrent arrhythmias.

View Article and Find Full Text PDF

Right-sided infective endocarditis (IE) accounts for 5% to 10% of all IE cases. Compared with left-sided IE, it is more often associated with intravenous drug abuse and intracardiac devices, whereas the latter has become more prevalent in recent decades. The authors report the first case of IE in a heterotopic caval valved stent used for treating torrential tricuspid regurgitation.

View Article and Find Full Text PDF

Background: The implantation procedure of left ventricular (LV) leads and the management of cardiac resynchronization therapy (CRT) patients can be challenging. The IS-4 standard for CRT offers additional pacing vectors compared to bipolar leads (IS-1). IS-4 leads improve procedural outcome and may also result in lower adverse events during follow-up (FU) and improve clinical outcome in CRT patients.

View Article and Find Full Text PDF

Conduction system pacing (CSP) encompassing His bundle (HBP) and left bundle branch area pacing (LBBAP) is gaining increasing attention in the electrophysiology community. These relatively novel physiological pacing modalities have the potential to outperform conventional pacing approaches with respect to clinical endpoints, although data are currently still limited. While HBP represents the most physiological form of cardiac stimulation, success rates, bundle branch correction, and electrical lead performance over time remain a concern.

View Article and Find Full Text PDF

Background: We describe our initial experience using a multipolar pulsed-field ablation catheter for the treatment of left atrial (LA) reentry tachycardia.

Methods: We included all patients with LA reentry tachycardia treated with PFA at our institution between September 2021 and March 2022. The tachycardia mechanism was identified using 3D electro-anatomical mapping (3D-EAM).

View Article and Find Full Text PDF

Aims: Subcutaneous implantable cardioverter defibrillators (S-ICDs) are well established. However, inappropriate shocks (IAS) remain a source of concern since S-ICDs offer very limited troubleshooting options. In our multicentre case series, we describe several patients who experienced IAS due to a previously unknown S-ICD system issue.

View Article and Find Full Text PDF

Background: A pace and ablate strategy may be performed in refractory atrial fibrillation with rapid ventricular response. Objective: We aimed to assess sex-related differences in patient selection and clinical outcomes after pace and ablate. Methods: In a retrospective multicentre study, patients undergoing AV junction ablation were studied.

View Article and Find Full Text PDF

Aims: To validate the performance of a multipolar pulsed-field ablation (PFA) catheter compared to a standard pentaspline 3D-mapping catheter for endpoint assessment of pulmonary vein isolation (PVI). PFA for PVI using single-shot devices combines the benefits of high procedural efficacy and safety. A newly available multipolar PFA catheter allows real-time recording of pulmonary vein (PV) signals during PVI.

View Article and Find Full Text PDF