Publications by authors named "Norifumi Mizuno"

Article Synopsis
  • FMEA (Failure Mode and Effects Analysis) is gaining traction in radiotherapy for its effectiveness in preventing errors and can be carried out by individuals or groups online.
  • A web-based FMEA risk analysis worksheet was developed using Google tools to make it more accessible and user-friendly for various purposes.
  • The worksheet proved effective for both individual and group settings, allowing simultaneous online editing and automation to streamline the analysis process, ultimately enhancing collaboration and safety.
View Article and Find Full Text PDF

Introduction Whole lung irradiation (WLI) is used for the treatment of lung metastasis in Wilms tumor and Ewing sarcoma; however, cardiac complications are one of the concerns. We report the dosimetric advantages of WLI using volumetric-modulated arc therapy (VMAT) and present a dosimetric comparison of VMAT with anteroposterior-posteroanterior (AP-PA) and static-field intensity-modulated radiation therapy (IMRT). Additionally, we evaluated the dosimetric impact of respiratory motion and intra-fractional motion during VMAT treatment.

View Article and Find Full Text PDF

Manual delineation of organs at risk and clinical target volumes is essential in radiotherapy planning. Atlas-based auto-segmentation (ABAS) algorithms have become available and been shown to provide accurate contouring for various anatomical sites. Recently, deep learning auto-segmentation (DL-AS) algorithms have emerged as the state-of-the-art in medical image segmentation.

View Article and Find Full Text PDF

Background And Purpose: Quality indicators (QIs) for radiotherapy have been proposed by several groups, but no study has been conducted to correlate the implementation of indicators specific to patient safety over the course of the clinical process with an institution's background. An initial large-scale survey was conducted to understand the implementation status of QIs established for quality assurance and patient safety in radiotherapy and the relationship between implementation status and an institutions' background.

Materials And Method: Overall, 68 QIs that were established by this research team after a pilot survey were used to assess structures and processes for quality assurance and patient safety.

View Article and Find Full Text PDF

External beam accelerated partial breast irradiation (APBI) is an alternative treatment for patients with early-stage breast cancer. The efficacy of image-guided radiotherapy (IGRT) using fiducial markers, such as gold markers or surgical clips, has been demonstrated. However, the effects of respiratory motion during a single fraction have not been reported.

View Article and Find Full Text PDF

This study aimed to evaluate the robustness against geometric uncertainties in the hybrid intensity-modulated radiation therapy (IMRT) plans generated by commercially available software for automated breast planning (ABP). The ABP plans were compared with commonly used forward-planned field-in-field (FIF) technique plans. The planning computed tomography datasets of 20 patients who received left-sided breast-conserving surgery were used for both the ABP and FIF plans.

View Article and Find Full Text PDF

Introduction: Deep inspiration breath-hold (DIBH) for left-sided breast cancer radiotherapy reduces the dose exposure of the heart and left anterior descending coronary artery. DIBH requires the patient to maintain an adequate breath-hold position during their daily radiotherapy fraction. This study aimed to assess the reproducibility of the breath-hold position by implementing DIBH with visual feedback (VF) system.

View Article and Find Full Text PDF

Purpose: Accelerated partial breast irradiation (APBI) is alternative treatment option for patients with early stage breast cancer. The interplay effect on volumetric modulated arc therapy APBI (VMAT-APBI) has not been clarified. This study aimed to evaluate the feasibility of VMAT-APBI for patients with small breasts and investigate the amplitude of respiratory motion during VMAT-APBI delivery that significantly affects dose distribution.

View Article and Find Full Text PDF

This study investigates the quality indicators (QIs) of medical care that are expected to be introduced to radiotherapy departments in Japan and evaluates whether the QIs reflect the characteristics of the treatment facilities. For this purpose, a questionnaire survey was administered to radiotherapy treatment facilities in Japan. A consensus of early QI candidates was obtained from the panel members.

View Article and Find Full Text PDF

Purpose: The beam model in radiation treatment planning systems (RTPSs) plays a crucial role in determining the accuracy of calculated dose distributions. The purpose of this study was to ascertain differences in beam models and their dosimetric influences when a golden beam dataset (GBD) and multi-institution measured beam datasets (MBDs) are used for beam modeling in RTPSs.

Methods: The MBDs collected from 15 institutions, and the MBDs' beam models, were compared with a GBD, and the GBD's beam model, for Varian TrueBeam linear accelerator.

View Article and Find Full Text PDF

Purpose: Ionization chambers are widely used for dosimetry with megavoltage photon beams. Several properties of ionization chambers, including the cable effect, polarity effect, and ion recombination loss, are described in standard dosimetry protocols. The cable effect is categorized as the leakage current and Compton current, and careful consideration of these factors has been described not only in reference dosimetry but also in large fields.

View Article and Find Full Text PDF
Article Synopsis
  • * TG-100 is applicable to various advanced technologies in radiotherapy, aiming to improve safety measures and overall process efficiency.
  • * The methodology focuses on identifying vulnerabilities in treatment procedures by evaluating potential failure modes, highlighting the need for skilled staff and proper resources in modern radiotherapy.
View Article and Find Full Text PDF

Deep inspiration breath hold (DIBH) is a common method used worldwide for reducing the radiation dose to the heart. However, few studies have reported on the relationship between dose reduction and patient-specific parameters. The aim of this study was to compare the reductions of heart dose and volume using DIBH with the dose/volume of free breathing (FB) for patients with left-sided breast cancer and to analyse patient-specific dose reduction parameters.

View Article and Find Full Text PDF

Automated treatment planning may decrease the effort required in planning and promote increased routine clinical use of intensity-modulated radiation therapy (IMRT) for many breast cancer patients. The aim of this study was to evaluate a new commercial automated planning software for tangential breast IMRT by comparing it with clinical plans from whole-breast irradiation. We prospectively enrolled 150 patients with Stage 0-1 breast cancer who underwent breast-conserving surgery at our institution between September 2016 and August 2017.

View Article and Find Full Text PDF

In inhomogeneous media, there is often a large systematic difference in the dose between the conventional Clarkson algorithm (C-Clarkson) for independent calculation verification and the superposition-based algorithms of treatment planning systems (TPSs). These treatment site-dependent differences increase the complexity of the radiotherapy planning secondary check. We developed a simple and effective method of heterogeneity correction integrated with the Clarkson algorithm (L-Clarkson) to account for the effects of heterogeneity in the lateral dimension, and performed a multi-institutional study to evaluate the effectiveness of the method.

View Article and Find Full Text PDF

In this study, the optimum density scaling factors of phantom materials for a commercially available three-dimensional (3D) dose verification system (Delta4) were investigated in order to improve the accuracy of the calculated dose distributions in the phantom materials. At field sizes of 10 × 10 and 5 × 5 cm with the same geometry, tissue-phantom ratios (TPRs) in water, polymethyl methacrylate (PMMA), and Plastic Water Diagnostic Therapy (PWDT) were measured, and TPRs in various density scaling factors of water were calculated by Monte Carlo simulation, Adaptive Convolve (AdC, Pinnacle ), Collapsed Cone Convolution (CCC, RayStation), and AcurosXB (AXB, Eclipse). Effective linear attenuation coefficients (μ ) were obtained from the TPRs.

View Article and Find Full Text PDF

Some patients undergoing breast reconstruction require post-mastectomy radiation therapy, but the metallic ports used in temporary tissue expanders attenuate the X-rays. In this study, we evaluated by the film method, the attenuation of 4 MV and 6 MV X-rays after passing through a metallic port, with the aim of identifying a useful method for determining the appropriate density to use in the radiation treatment planning system (RTPS), taking into account the distance between the metallic port and the targets. Radiochromic film was used to measure depth doses after the X-rays passed through the metallic port.

View Article and Find Full Text PDF

Purpose: The aim of the present investigation was to evaluate the dosimetric variation regarding the analytical anisotropic algorithm (AAA) relative to other algorithms in lung stereotactic body radiation therapy (SBRT). We conducted a multi-institutional study involving six institutions using a secondary check program and compared the AAA to the Acuros XB (AXB) in two institutions.

Methods: All lung SBRT plans (128 patients) were generated using the AAA, pencil beam convolution with the Batho (PBC-B) and adaptive convolve (AC).

View Article and Find Full Text PDF

Purpose: The purpose of this study was to quantify the target coverage, homogeneity, and robustness of the dose distributions against geometrical uncertainties associated with four whole breast radiotherapy techniques.

Methods: The study was based on the planning-computed tomography-datasets of 20 patients who underwent whole breast radiotherapy. A total of four treatment plans (wedge, field-in-field [FIF], hybrid intensity-modulated radiotherapy [IMRT], and full IMRT) were created for each patient.

View Article and Find Full Text PDF

Volumetric-modulated arc therapy (VMAT) is a widespread intensity-modulated radiation therapy (IMRT) method, however, VMAT requires adaptation of the radiation treatment planning system (RTPS) and linear accelerator (linac); these upgrades are quite expensive. The Smart Arc of Pinnacle(3) (Philips), which is the software used in VMAT calculations, can select constant dose rate (CDR) mode. This approach has a low initial cost because the linac upgrade is not required.

View Article and Find Full Text PDF

Purpose: This study aims to clarify the time-course of gas accumulation in the rectum during treatment as guidance for the management of rectal volumes.

Materials And Methods: We reviewed 2042 sets (35.2 sets per patient) of anteroposterior and right-left mega voltage (MV) images obtained for daily set-up from 58 patients who underwent radical external beam radiotherapy for localised prostate cancer.

View Article and Find Full Text PDF