IEEE Trans Biomed Eng
March 2024
Objective: Cochlear implant signal processing strategies define the rules of how acoustic signals are converted into electrical stimulation patterns. Technological and anatomical limitations, however, impose constraints on the signal transmission and the accurate excitation of the auditory nerve. Acoustic signals are degraded throughout cochlear implant processing, and electrical signal interactions at the electrode-neuron interface constrain spectral and temporal precision.
View Article and Find Full Text PDFObjective: This study aimed to investigate the relationship between cochlear implant (CI) electrode distances to the cochlea's inner wall (the modiolus) and electrical impedance measurements made at the CI's electrode contacts. We introduced a protocol for "three-point impedances" in which we recorded bipolar impedances in response to monopolar stimulation at a neighboring electrode. We aimed to assess the usability of three-point impedances and two existing CI impedance measurement methods (monopolar and four-point impedances) for predicting electrode positioning during CI insertion.
View Article and Find Full Text PDFObjective: This study compared two different versions of an electrophysiology-based software-guided cochlear implant fitting method with a procedure employing standard clinical software. The two versions used electrically evoked compound action potential (ECAP) thresholds for either five or all twenty-two electrodes to determine sound processor stimulation level profiles. Objective and subjective performance results were compared between software-guided and clinical fittings.
View Article and Find Full Text PDFBackground: Models of auditory nerve fiber (ANF) responses to electrical stimulation are helpful to develop advanced coding for cochlear implants (CIs). A phenomenological model of ANF population responses to CI electrical stimulation with a lower computational complexity compared to a biophysical model would be beneficial to evaluate new CI coding strategies.
New Method: This study presents a phenomenological model which combines four temporal characteristics of ANFs (refractoriness, facilitation, accommodation and spike rate adaptation) in addition to a spatial spread of the electric field.
The use of electrocochleography (ECochG) for providing real-time feedback of cochlear function during cochlear implantation is receiving increased attention for preventing cochlear trauma and preserving residual hearing. Although various studies investigated the relationship between intra-operative ECochG measurements and surgical outcomes in recent years, the limited interpretability of ECochG response changes leads to conflicting study results and prevents the adoption of this method for clinical use. Specifically, the movement of the recording electrode with respect to the different signal generators in intracochlear recordings makes the interpretation of signal changes with respect to cochlear trauma difficult.
View Article and Find Full Text PDFA bio-inspired coding (BIC) strategy was implemented in this study with the goal of better representation of spectral and temporal information. The auditory nerve fibers' (ANFs) characteristics such as refractory recovery, facilitation and spatial spread were obtained from ECAP data recorded in 11 CI recipients. These characteristics, together with a non-individualized model-derived adaptation effect, were integrated into the BIC strategy for a better selection of channels.
View Article and Find Full Text PDFAuditory nerve fibers' (ANFs) refractoriness and facilitation can be quantified in electrically evoked compound action potentials (ECAPs) recorded via neural response telemetry (NRT). Although facilitation has been observed in animals and human cochlear implant (CI) recipients, no study has modeled this in human CI users until now. In this study, recovery and facilitation effects at different masker and probe levels for three test electrodes (E6, E12 and E18) in 11 CI subjects were recorded.
View Article and Find Full Text PDFTo gain more insight into central hearing loss, we investigated the relationship between cortical thickness and surface area, speech-relevant resting state EEG power, and above-threshold auditory measures in older adults and younger controls. Twenty-three older adults and 13 younger controls were tested with an adaptive auditory test battery to measure not only traditional pure-tone thresholds, but also above individual thresholds of temporal and spectral processing. The participants' speech recognition in noise (SiN) was evaluated, and a T1-weighted MRI image obtained for each participant.
View Article and Find Full Text PDFJ Neurosci Methods
February 2017
Background: Contemporary speech processing strategies in cochlear implants (CIs) such as the Advanced Combination Encoder (ACE) use a standard Fast Fourier Transform (FFT) filterbank to extract envelopes. The assignment of the FFT bins to approximate the frequency resolution of the basilar membrane is only partly based on physiology, especially since the bins are distributed linearly below 1000Hz and logarithmically above 1000Hz.
New Method: A Gammatone filterbank which provides a closer approximation to the bandwidths of filters in the human auditory system could replace the standard FFT filterbank in the ACE strategy.
The Nucleus(®) 5 System Sound Processor (CP810, Cochlear™, Macquarie University, NSW, Australia) contains two omnidirectional microphones. They can be configured as a fixed directional microphone combination (called Zoom) or as an adaptive beamformer (called Beam), which adjusts the directivity continuously to maximally reduce the interfering noise. Initial evaluation studies with the CP810 had compared performance and usability of the new processor in comparison with the Freedom™ Sound Processor (Cochlear™) for speech in quiet and noise for a subset of the processing options.
View Article and Find Full Text PDFMost simulations of cochlear implant (CI) coding strategies rely on standard vocoders that are based on purely signal processing techniques. However, these models neither account for various biophysical phenomena, such as neural stochasticity and refractoriness, nor for effects of electrical stimulation, such as spectral smearing as a function of stimulus intensity. In this paper, a neural model that accounts for stochastic firing, parasitic spread of excitation across neuron populations, and neuronal refractoriness, was developed and augmented as a preprocessing stage for a standard 22-channel noise-band vocoder.
View Article and Find Full Text PDFPurpose: Background sounds provided by a wearable sound playback device were mixed with the acoustical input picked up by a cochlear implant speech processor in an attempt to suppress tinnitus.
Method: First, patients were allowed to listen to several sounds and to select up to 4 sounds that they thought might be effective. These stimuli were programmed to loop continuously in the wearable playback device.
Objective: To provide guidelines for the development of two types of closed-set speech-perception tests that can be applied and interpreted in the same way across languages. The guidelines cover the digit triplet and the matrix sentence tests that are most commonly used to test speech recognition in noise. They were developed by a working group on Multilingual Speech Tests of the International Collegium of Rehabilitative Audiology (ICRA).
View Article and Find Full Text PDFObjective: To describe the principles and operation of a new telemetry-based function test for the Nucleus® cochlear implant, known as the CS19 Intra-Cochlear Impedance Matrix (IIM) and to present results from a multicentre clinical study to establish reproducibility (test-retest reliability) and normative ranges.
Method: The IIM test measures bipolar impedances between all electrode pairs and employs a normalization procedure based on common ground impedances in order to identify abnormal current paths among electrodes. Six European clinics collected IIM data from a total of 192 devices.
Objectives: To compare speech perception outcomes between bilateral implantation (cochlear implants [CIs]) and bimodal rehabilitation (one CI on one side plus one hearing aid [HA] on the other side) and to explore the clinical factors that may cause asymmetric performances in speech intelligibility between the two ears in case of bilateral implantation.
Design: Retrospective data from 2247 patients implanted since 2003 in 15 international centers were collected. Intelligibility scores, measured in quiet and in noise, were converted into percentile ranks to remove differences between centers.
Custom Sound EP™ (CSEP) is an advanced flexible software tool dedicated to recording of electrically evoked compound action potentials (ECAPs) in Nucleus® recipients using Neural Response Telemetry™ (NRT™). European multi-centre studies of the Freedom™ cochlear implant system confirmed that CSEP offers tools to effectively record ECAP thresholds, amplitude growth functions, recovery functions, spread of excitation functions, and rate adaptation functions and an automated algorithm (AutoNRT™) to measure threshold profiles. This paper reports on rate adaptation measurements.
View Article and Find Full Text PDFThe cochlear implant (CI) is one of the most successful neural prostheses developed to date. It offers artificial hearing to individuals with profound sensorineural hearing loss and with insufficient benefit from conventional hearing aids. The first implants available some 30 years ago provided a limited sensation of sound.
View Article and Find Full Text PDFBilateral cochlear implant (CI) users encounter difficulties in localizing sound sources in everyday environments, especially in the presence of background noise and reverberation. They tend to show large directional errors and front-back confusions compared to normal hearing (NH) subjects in the same conditions. In this study, the ability of bilateral CI users to use head movements to improve sound source localization was evaluated.
View Article and Find Full Text PDFObjective: To test the influence of multiple factors on cochlear implant (CI) speech performance in quiet and in noise for postlinguistically deaf adults, and to design a model of predicted auditory performance with a CI as a function of the significant factors.
Study Design: Retrospective multi-centre study.
Methods: Data from 2251 patients implanted since 2003 in 15 international centres were collected.
Objective: To update a 15-year-old study of 800 postlinguistically deaf adult patients showing how duration of severe to profound hearing loss, age at cochlear implantation (CI), age at onset of severe to profound hearing loss, etiology and CI experience affected CI outcome.
Study Design: Retrospective multicenter study.
Methods: Data from 2251 adult patients implanted since 2003 in 15 international centers were collected and speech scores in quiet were converted to percentile ranks to remove differences between centers.
Sound localization with hearing aids has traditionally been investigated in artificial laboratory settings. These settings are not representative of environments in which hearing aids are used. With individual Head-Related Transfer Functions (HRTFs) and room simulations, realistic environments can be reproduced and the performance of hearing aid algorithms can be evaluated.
View Article and Find Full Text PDFObjective: The primary objective was to report on experiences regarding the safety and efficacy of the Vibrant Soundbridge (VSB) using a floating mass transducer (FMT)-partial/total ossicular replacement prosthesis (PORP/TORP) assembly as a treatment for conductive and mixed hearing losses of mild-to-moderate/severe degree. The secondary objective was to gather information regarding device fitting, as well as to refine surgical procedures.
Patients: Five German-speaking adults from 2 European study sites were implanted with a VSB using an FMT-PORP/TORP assembly and evaluated before and after surgery for air-and bone-conduction thresholds and speech recognition performance.
Efficacy of the SPEAK and ACE coding strategies was compared with that of a new strategy, MP3000™, by 37 European implant centers including 221 subjects. The SPEAK and ACE strategies are based on selection of 8-10 spectral components with the highest levels, while MP3000 is based on the selection of only 4-6 components, with the highest levels relative to an estimate of the spread of masking. The pulse rate per component was fixed.
View Article and Find Full Text PDFIn this prospective multicenter study, tinnitus loudness and tinnitus-related distress were investigated in 174 cochlear implant (CI) candidates who underwent CI surgery at a Swiss cochlear implant center. All subjects participated in two session, one preoperatively and one 6 months after device activation. In both sessions, tinnitus loudness was assessed using a visual analogue scale and tinnitus distress using a standardized tinnitus questionnaire.
View Article and Find Full Text PDF