Publications by authors named "Nora L Maidana"

Dead-time effects in X-ray spectra taken with a digital pulse processor and a silicon drift detector were investigated when the number of events at the low-energy end of the spectrum was more than half of the total, at counting rates up to 56 kHz. It was found that dead-time losses in the spectra are energy dependent and an analytical correction for this effect, which takes into account pulse pile-up, is proposed. This and the usual models have been applied to experimental measurements, evaluating the dead-time fraction either from the calculations or using the value given by the detector acquisition system.

View Article and Find Full Text PDF

The peak efficiency for photons hitting the frontal surface of a medium volume n-type HPGe coaxial detector is mapped using acutely collimated beams of energies between 31 and 383 keV from a (133)Ba radioactive source. Simulated values obtained with the Monte Carlo radiation transport code penelope, using a model that respected actual detector dimensions and physical constants while varying dead-layer thicknesses, allowed us to fit the experimental results in the detector bulk but not near its rim. The spectra of a (137)Cs source were measured using the detector shielded from the natural background radiation, with and without a broad angle collimator.

View Article and Find Full Text PDF

The extrapolation chamber is a parallel-plate ionization chamber that allows variation of its air-cavity volume. In this work, an experimental study and MCNP-4C Monte Carlo code simulations of an ionization chamber designed and constructed at the Calibration Laboratory at IPEN to be used as a secondary dosimetry standard for low-energy X-rays are reported. The results obtained were within the international recommendations, and the simulations showed that the components of the extrapolation chamber may influence its response up to 11.

View Article and Find Full Text PDF

A gamma-gamma coincidence experiment was performed to check the 152Eu 13-year decay scheme and the placement of the observed gamma-ray transitions. The multi-detector array for residual activity measurement of the Linear Accelerator Laboratory was used. The source activity was 1 MBq, and about 10(9) coincidence events were observed.

View Article and Find Full Text PDF

The procedure to determine the statistical correlations between gamma-ray intensities is described here, as well as that required to take these correlations into account. The advantages of using branching-ratios and feeding fractions instead of gamma-ray intensities in the gamma-ray standards are discussed.

View Article and Find Full Text PDF