Purpose: To investigate the utility and generalizability of deep learning subtraction angiography (DLSA) for generating synthetic digital subtraction angiography (DSA) images without misalignment artifacts.
Materials And Methods: DSA images and native digital angiograms of the cerebral, hepatic, and splenic vasculature, both with and without motion artifacts, were retrospectively collected. Images were divided into a motion-free training set (n = 66 patients, 9,161 images) and a motion artifact-containing test set (n = 22 patients, 3,322 images).
IEEE Trans Med Imaging
March 2023
Deep-learning (DL) based CT image generation methods are often evaluated using RMSE and SSIM. By contrast, conventional model-based image reconstruction (MBIR) methods are often evaluated using image properties such as resolution, noise, bias. Calculating such image properties requires time consuming Monte Carlo (MC) simulations.
View Article and Find Full Text PDFJ Med Imaging (Bellingham)
February 2022
: For 50 years now, SPIE Medical Imaging (MI) conferences have been the premier forum for disseminating and sharing new ideas, technologies, and concepts on the physics of MI. : Our overarching objective is to demonstrate and highlight the major trajectories of imaging physics and how they are informed by the community and science present and presented at SPIE MI conferences from its inception to now. : These contributions range from the development of image science, image quality metrology, and image reconstruction to digital x-ray detectors that have revolutionized MI modalities including radiography, mammography, fluoroscopy, tomosynthesis, and computed tomography (CT).
View Article and Find Full Text PDFWe are interested in learning the hyperparameters in a convex objective function in a supervised setting. The complex relationship between the input data to the convex problem and the desirable hyperparameters can be modeled by a neural network; the hyperparameters and the data then drive the convex minimization problem, whose solution is then compared to training labels. In our previous work (Xu and Noo 202119NT01), we evaluated a prototype of this learning strategy in an optimization-based sinogram smoothing plus FBP reconstruction framework.
View Article and Find Full Text PDFPhys Med Biol
March 2022
The past decade has seen the rapid growth of model based image reconstruction (MBIR) algorithms, which are often applications or adaptations of convex optimization algorithms from the optimization community. We review some state-of-the-art algorithms that have enjoyed wide popularity in medical image reconstruction, emphasize known connections between different algorithms, and discuss practical issues such as computation and memory cost. More recently, deep learning (DL) has forayed into medical imaging, where the latest development tries to exploit the synergy between DL and MBIR to elevate the MBIR's performance.
View Article and Find Full Text PDFPhys Med Biol
September 2021
We propose a hyperparameter learning framework that learnshyperparameters for optimization-based image reconstruction problems for x-ray CT applications. The framework consists of two functional modules: (1) a hyperparameter learning module parameterized by a convolutional neural network, (2) an image reconstruction module that takes as inputs both the noisy sinogram and the hyperparameters from (1) and generates the reconstructed images. As a proof-of-concept study, in this work we focus on a subclass of optimization-based image reconstruction problems with exactly computable solutions so that the whole network can be trained end-to-end in an efficient manner.
View Article and Find Full Text PDFIEEE Trans Radiat Plasma Med Sci
January 2020
For situations of cone-beam scanning where the measurements are incomplete, we propose a method to quantify the severity of the missing information at each voxel. This incompleteness metric is geometric; it uses only the relative locations of all cone-beam vertices with respect to the voxel in question, and does not apply global information such as the object extent or the pattern of incompleteness of other voxels. The values are non-negative, with zero indicating "least incompleteness," i.
View Article and Find Full Text PDFThree-dimensional cone-beam imaging has become valuable in interventional radiology. Currently, this tool, referred to as C-arm CT, employs a circular short-scan for data acquisition, which limits the axial volume coverage and yields unavoidable cone-beam artifacts. To improve flexibility in axial coverage and image quality, there is a critical need for novel data acquisition geometries and related image reconstruction algorithms.
View Article and Find Full Text PDFJoint image reconstruction for multiphase CT can potentially improve image quality and reduce dose by leveraging the shared information among the phases. Multiphase CT scans are acquired sequentially. Inter-scan patient breathing causes small organ shifts and organ boundary misalignment among different phases.
View Article and Find Full Text PDFPurpose: The computational burden associated with model-based iterative reconstruction (MBIR) is still a practical limitation. Iterative coordinate descent (ICD) is an optimization approach for MBIR that has sometimes been thought to be incompatible with modern computing architectures, especially graphics processing units (GPUs). The purpose of this work is to accelerate the previously released open-source FreeCT_ICD to include GPU acceleration and to demonstrate computational performance with ICD that is comparable with simultaneous update approaches.
View Article and Find Full Text PDFPurpose: Model-based iterative reconstruction is a promising approach to achieve dose reduction without affecting image quality in diagnostic x-ray computed tomography (CT). In the problem formulation, it is common to enforce non-negative values to accommodate the physical non-negativity of x-ray attenuation. Using this a priori information is believed to be beneficial in terms of image quality and convergence speed.
View Article and Find Full Text PDFPurpose: An important challenge for deep learning models is generalizing to new datasets that may be acquired with acquisition protocols different from the training set. It is not always feasible to expand training data to the range encountered in clinical practice. We introduce a new technique, physics-based data augmentation (PBDA), that can emulate new computed tomography (CT) data acquisition protocols.
View Article and Find Full Text PDFPurpose: To facilitate investigations into the impacts of acquisition and reconstruction parameters on quantitative imaging, radiomics and CAD using CT imaging, we previously released an open-source implementation of a conventional weighted filtered backprojection reconstruction called FreeCT_wFBP. Our purpose was to extend that work by providing an open-source implementation of a model-based iterative reconstruction method using coordinate descent optimization, called FreeCT_ICD.
Methods: Model-based iterative reconstruction offers the potential for substantial radiation dose reduction, but can impose substantial computational processing and storage requirements.
IEEE Trans Med Imaging
January 2018
We present a direct (noniterative) algorithm for 1-D quadratic data fitting with neighboring intensity differences penalized by the Huber function. Applications of such an algorithm include 1-D processing of medical signals, such as smoothing of tissue time concentration curves in kinetic data analysis or sinogram preprocessing, and using it as a subproblem solver for 2-D or 3-D image restoration and reconstruction. dynamic programming was used to develop the direct algorithm.
View Article and Find Full Text PDFPhys Med Biol
September 2017
We show that two problems involving the anisotropic total variation (TV) and interval constraints on the unknown variables admit, under some conditions, a simple sequential solution. Problem 1 is a constrained TV penalized image denoising problem; problem 2 is a constrained fused lasso signal approximator. The sequential solution entails finding first the solution to the unconstrained problem, and then applying a thresholding to satisfy the constraints.
View Article and Find Full Text PDFPurpose: Lung cancer screening with low-dose CT has recently been approved for reimbursement, heralding the arrival of such screening services worldwide. Computer-aided detection (CAD) tools offer the potential to assist radiologists in detecting nodules in these screening exams. In lung screening, as in all CT exams, there is interest in further reducing radiation dose.
View Article and Find Full Text PDFPurpose: Recent reports indicate that model-based iterative reconstruction methods may improve image quality in computed tomography (CT). One difficulty with these methods is the number of options available to implement them, including the selection of the forward projection model and the penalty term. Currently, the literature is fairly scarce in terms of guidance regarding this selection step, whereas these options impact image quality.
View Article and Find Full Text PDFIEEE Trans Nucl Sci
June 2016
Positron emission tomography (PET) images are typically reconstructed with an in-plane pixel size of approximately 4mm for cancer imaging. The objective of this work was to evaluate the effect of using smaller pixels on general oncologic lesion-detection. A series of observer studies was performed using experimental phantom data from the Utah PET Lesion Detection Database, which modeled whole-body FDG PET cancer imaging of a 92kg patient.
View Article and Find Full Text PDFPurpose: With growing interest in quantitative imaging, radiomics, and CAD using CT imaging, the need to explore the impacts of acquisition and reconstruction parameters has grown. This usually requires extensive access to the scanner on which the data were acquired and its workflow is not designed for large-scale reconstruction projects. Therefore, the authors have developed a freely available, open-source software package implementing a common reconstruction method, weighted filtered backprojection (wFBP), for helical fan-beam CT applications.
View Article and Find Full Text PDFRecent reports show that three-dimensional cone-beam (CB) imaging with a floor-mounted (or ceiling-mounted) C-arm system has become a valuable tool in interventional radiology. Currently, a circular short scan is used for data acquisition, which inevitably yields CB artifacts and a short coverage in the direction of the patient table. To overcome these two limitations, a more sophisticated data acquisition geometry is needed.
View Article and Find Full Text PDF