Purpose: This study was conducted to investigate the accuracy of intraoral scanner (IOS) for recording maximal intercuspal position (MIP) and border positions of the mandible.
Materials And Methods: Maxillary and mandibular master casts were articulated in MIP, protrusive, and lateral interocclusal position sequentially on a semi-adjustable articulator. For each articulation relation, sites of occlusal contacts (SOCs) and sites of clearance (SCs) were identified on the master casts with articulating paper (reference sites).
Statement Of Problem: Occlusal veneers are a conservative method of reestablishing vertical dimensions of occlusion (VDO) for worn teeth. A restorative material used for occlusal veneers should have a smooth surface, adequate wear resistance, and low abrasiveness to the antagonists, as total wear of occlusal veneers and their antagonists determines the stability of the reestablished VDO. Studies on roughness, wear, and abrasiveness of occlusal veneers are scarce.
View Article and Find Full Text PDFBackground: Interim crowns are utilized for restoring implants during and after the process of osseointegration. However, studies on adaptation and fracture strength of implant-supported interim crowns are rare.
Aim Of The Study: The aim of this in vitro study is evaluating marginal fit and fracture resistance of conventional, subtractive, and additive methods of fabricating implant-supported interim crowns.
Purpose: To assess the accuracy of virtual articulation in direct digital workflow (DDW) and indirect digital workflow (IDW) in arches prepared for fixed partial dentures (FPDs).
Materials And Methods: Five pairs of master models were used in this study representing different clinical scenarios of full dentate (FD), and prepared arches for fixed partial dentures as follows: FD group, short span posterior (SSP group), long span posterior (LSP group), short span anterior (SSA group), and long span anterior (LSA). Fourteen pairs of interarch reference points were added to each set of master models to measure linear interarch distance with a caliper (reference measurements).
Background: Cement spacer is essential for compensating deformation of zirconia restoration after sintering shrinkage, allowing proper seating and better fracture resistance of the restoration. Studies assessing the effect of cement spacer on fit accuracy and fracture strength of zirconia frameworks are missing in the literature. Therefore, the aim of this study was to evaluate the effect of different cement spacer settings on fit accuracy and fracture strength of 3-unit and 4-unit zirconia frameworks.
View Article and Find Full Text PDFStatement Of Problem: The surface topography of metal substrate can affect its bond to porcelain. A neodynium-doped yttrium aluminum garnet (Nd:YAG) laser has been introduced to modify the metal surface topography and improve porcelain bond strength. However, studies on the effect of laser etching on metal to porcelain bond strength are lacking.
View Article and Find Full Text PDFStatement Of Problem: Cement spacer has a crucial influence on the adaptation of fixed restorations. Recently, digitally fabricated zirconia crowns have become more popular, but studies on the effect of occlusal cement spacer on the fit accuracy of digitally designed and milled zirconia crowns are lacking.
Purpose: The purpose of this in vitro study was to investigate the effect of modifying digital occlusal spacer on the marginal and internal fit of digitally manufactured zirconia crowns.
Background: Shade determination is a critical step for the fabrication of a satisfactory restoration. Visual shade selection with conventional shade guides is subjective and influenced by variables related to light, observer, and object. Shade selection devices have been introduced to provide subjective and quantitative shade values.
View Article and Find Full Text PDFBackground: Clinical studies comparing the accuracy of digital and conventional records for static interocclusal registration are lacking. Therefore, the purpose of this clinical study was to assess the precision of digital interocclusal registration compared to conventional registration for full arch and quadrant arch conditions.
Methods: Nine individuals with complete natural dentition were enrolled in this study.
Statement Of Problem: Static virtual articulation with intraoral scanners (IOSs) can eliminate the human errors related to conventional articulation methods and enhance accuracy. A systematic review and meta-analysis based on multiple accuracy outcomes can combine the available literature and provide an evidence-based conclusion.
Purpose: The purpose of this systematic review and meta-analysis was to investigate whether static virtual articulation with IOSs has acceptable accuracy for completely dentate and partially edentulous patients.
Statement Of Problem: Available studies comparing fit accuracy of zirconia fixed partial dentures (FPDs) fabricated from conventional impressions and digital scans provide contradictory results. In addition, studies have been heterogeneous and of a limited number to provide conclusive evidence.
Purpose: The purpose of this systematic review and meta-analysis was to compare the marginal and intaglio fit of tooth-supported zirconia FPDs fabricated from conventional impressions and digital scans and to investigate the effect of different variables on the fit results.
Objectives: This study aimed to compare the accuracy of conventional and digital impressions based on the fit of produced three-unit fixed partial dentures (FPDs) in vivo and the trueness and precision of both impression techniques.
Materials And Methods: Twelve patients received a conventional polyether impression (group C, control, n=12) and a digital impression with CS3500 (group D, test, n=12) for each participant. Monolithic multilayer zirconia FPDs were fabricated, and the internal and marginal fit were assessed using the replica technique.
Thermal inactivation of peroxidase (POD) and polyphenol oxidase (PPO) in both pomegranate arils crude enzyme extract and fresh juice was investigated. The optimum conditions for reactions were studied using a mixture of guaiacol and HO as substrate for POD and pyrogallol for PPO. The experimental work indicated that optimum pH for both enzymes was 7.
View Article and Find Full Text PDFThe present study investigated the effects of adding the powder of cactus () seeds on the functional properties, fiber, antioxidants and acceptability of rice-based extrudates. The control blend consisting basically of rice flour was replaced with seed powder at 2, 4, 6, 8, 10, 15 and 20% then extruded at the optimum processing conditions. The extruded products were evaluated for their chemical composition, functional properties, color attributes, antioxidant activity and sensory characteristics.
View Article and Find Full Text PDFThis study aimed to evaluate the potential of near infrared spectroscopy (NIRS) as a fast and non-destructive tool for detecting and quantifying different adulterants in fresh and frozen-thawed minced beef. Partial least squares regression (PLSR) models were built under cross validation and tested with different independent data sets, yielding determination coefficients (R(P)(2)) of 0.96, 0.
View Article and Find Full Text PDF