Publications by authors named "Noel P"

Grating-based phase-contrast computed tomography (GBPC-CT) enables increased soft tissue differentiation, but often suffers from streak artifacts when performing high-sensitivity GBPC-CT of biomedical samples. Current GBPC-CT setups consist of one-dimensional gratings and hence allow to measure only the differential phase-contrast (DPC) signal perpendicular to the direction of the grating lines. Having access to the full two-dimensional DPC signal can strongly reduce streak artefacts showing up as characteristic horizontal lines in the reconstructed images.

View Article and Find Full Text PDF

Purpose: Evaluation of the influence of iterative reconstruction, tube settings and patient habitus on the accuracy of iodine quantification with dual-layer spectral CT (DL-CT).

Material And Methods: A CT abdomen phantom with different extension rings and four iodine inserts (1, 2, 5 and 10 mg/ml) was scanned on a DL-CT. The phantom was scanned with tube-voltages of 120 and 140 kVp and CTDI of 2.

View Article and Find Full Text PDF

This editorial comment refers to the article: Can We Perform CT of the Appendix with Less than 1 mSv? A De-escalating Dose-simulation Study. Park JH, et al., Eur Radiol, Dec 7, 2017.

View Article and Find Full Text PDF

Introduction: Effective delivery of healthcare in complex systems requires managing interdependencies between professions and organisational units. Reducing 30-day hospital readmissions may be one of the most complex tasks that a healthcare system can undertake. We propose that these less than optimal outcomes are related to difficulties managing the complex interdependencies among organisational units and to a lack of effective sensemaking among individuals and organisational units regarding how best to coordinate patient needs.

View Article and Find Full Text PDF

The International Myeloma Working Group has proposed the Revised International Staging System (R-ISS) for risk stratification of multiple myeloma (MM) patients. There are a limited number of studies that have validated this risk model in the autologous stem cell transplant (ASCT) setting. In this retrospective study, we evaluated the applicability and value for predicting survival of the R-ISS model in 134 MM patients treated with new agents and ASCT at the Mayo Clinic in Arizona and the University Hospital of Salamanca in Spain.

View Article and Find Full Text PDF

Social capital (SC) is highlighted as an important factor for post-crisis mental health outcomes. However, the heterogeneous nature of the construct makes it difficult to get a clear picture of the evidence concerning the association between SC indices and mental health. This review examines how SC is conceptualized and measured, and the relationships with other variables in quantitative empirical studies investigating the associations between SC and mental health in post-disaster and post-conflict contexts.

View Article and Find Full Text PDF

Multidetector computed tomography-based trabecular bone microstructure analysis ensures promising results in fracture risk prediction caused by osteoporosis. Because multidetector computed tomography is associated with high radiation exposure, its clinical routine use is limited. Hence, in this study, we investigated in 11 thoracic midvertebral specimens whether trabecular texture parameters are comparable derived from (1) images reconstructed using statistical iterative reconstruction (SIR) and filtered back projection as criterion standard at different exposures (80, 150, 220, and 500 mAs) and (2) from SIR-based sparse sampling projections (12.

View Article and Find Full Text PDF

Objectives: After endovascular aortic repair (EVAR), discrimination of endoleaks and intra-aneurysmatic calcifications within the aneurysm often requires multiphase computed tomography (CT). Spectral photon-counting CT (SPCCT) in combination with a two-contrast agent injection protocol may provide reliable detection of endoleaks with a single CT acquisition.

Methods: To evaluate the feasibility of SPCCT, the stent-lined compartment of an abdominal aortic aneurysm phantom was filled with a mixture of iodine and gadolinium mimicking enhanced blood.

View Article and Find Full Text PDF

The aim of this study was to assess the diagnostic value of x-ray dark-field radiography to detect pneumothoraces in a pig model. Eight pigs were imaged with an experimental grating-based large-animal dark-field scanner before and after induction of a unilateral pneumothorax. Image contrast-to-noise ratios between lung tissue and the air-filled pleural cavity were quantified for transmission and dark-field radiograms.

View Article and Find Full Text PDF

Objectives: Evaluation of imaging performance across dual-energy CT (DECT) platforms, including dual-layer CT (DLCT), rapid-kVp-switching CT (KVSCT) and dual-source CT (DSCT).

Methods: A semi-anthropomorphic abdomen phantom was imaged on these DECT systems. Scans were repeated three times for CTDIvol levels of 10 mGy, 20 mGy, 30 mGy and different fat-simulating extension rings.

View Article and Find Full Text PDF

Propagation-based phase-contrast tomography has become a valuable tool for visualization of three-dimensional biological samples, due to its high sensitivity and its potential in providing increased contrast between materials with similar absorption properties. We present a statistical iterative reconstruction algorithm for this imaging technique in the near-field regime. Under the assumption of a single material, the propagation of the x-ray wavefield-relying on the transport-of-intensity equation-is made an integral part of the tomographic reconstruction problem.

View Article and Find Full Text PDF

Unlabelled: This study investigated the feasibility of opportunistic osteoporosis screening in routine contrast-enhanced MDCT exams using texture analysis. The results showed an acceptable reproducibility of texture features, and these features could discriminate healthy/osteoporotic fracture cohort with an accuracy of 83%.

Introduction: This aim of this study is to investigate the feasibility of opportunistic osteoporosis screening in routine contrast-enhanced MDCT exams using texture analysis.

View Article and Find Full Text PDF

Background The explosive growth of computer tomography (CT) has led to a growing public health concern about patient and population radiation dose. A recently introduced technique for dose reduction, which can be combined with tube-current modulation, over-beam reduction, and organ-specific dose reduction, is iterative reconstruction (IR). Purpose To evaluate the quality, at different radiation dose levels, of three reconstruction algorithms for diagnostics of patients with proven liver metastases under tumor follow-up.

View Article and Find Full Text PDF

The performance of a recently introduced spectral computed tomography system based on a dual-layer detector has been investigated. A semi-anthropomorphic abdomen phantom for CT performance evaluation was imaged on the dual-layer spectral CT at different radiation exposure levels (CTDI of 10 mGy, 20 mGy and 30 mGy). The phantom was equipped with specific low-contrast and tissue-equivalent inserts including water-, adipose-, muscle-, liver-, bone-like materials and a variation in iodine concentrations.

View Article and Find Full Text PDF

To assess whether phantomless calcium-hydroxyapatite (HA) specific bone mineral density (BMD) measurements with dual-layer spectral computed tomography are accurate in phantoms and vertebral specimens. Ex-vivo human vertebrae (n = 13) and a phantom containing different known HA concentrations were placed in a semi-anthropomorphic abdomen phantom with different extension rings simulating different degrees of obesity. Phantomless dual-layer spectral CT was performed at different tube current settings (500, 250, 125 and 50 mAs).

View Article and Find Full Text PDF

Conventional x-ray radiography is a well-established standard in diagnostic imaging of human bones. It reveals typical bony anatomy with a strong surrounding cortical bone and trabecular structure of the inner part. However, due to limited spatial resolution, x-ray radiography cannot provide information on the microstructure of the trabecular bone.

View Article and Find Full Text PDF

Phase-contrast x-ray computed tomography (PCCT) is currently investigated as an interesting extension of conventional CT, providing high soft-tissue contrast even if examining weakly absorbing specimen. Until now, the potential for dose reduction was thought to be limited compared to attenuation CT, since meaningful phase retrieval fails for scans with very low photon counts when using the conventional phase retrieval method via phase stepping. In this work, we examine the statistical behaviour of the reverse projection method, an alternative phase retrieval approach and compare the results to the conventional phase retrieval technique.

View Article and Find Full Text PDF

Many cancer types, including pancreatic cancer, have a dense fibrotic stroma that plays an important role in tumor progression and invasion. Activated cancer associated fibroblasts are a key component of the tumor stroma that interact with cancer cells and support their growth and survival. Models that recapitulate the interaction of cancer cells and activated fibroblasts are important tools for studying the stromal biology and for development of antitumor agents.

View Article and Find Full Text PDF
Article Synopsis
  • Some political campaigns involve different strategies: some want to have discussions, while others only talk to people who agree with them.
  • The way these campaigns are set up can change how they compete against each other, especially when they adapt to their opponents.
  • In complicated situations with three or more competitors, weird results can happen, showing that sometimes a competitor’s extreme actions can change the outcome, even if those actions seem unlikely to win.
View Article and Find Full Text PDF
Article Synopsis
  • Grating-based X-ray interferometry enhances imaging of hard-to-see materials and tissues compared to standard X-ray methods.
  • An iterative reconstruction algorithm allows for achieving high image quality by directly processing the interferograms, avoiding the need for multiple grating movements.
  • This breakthrough enables the successful reconstruction of important coefficients with just one measurement per angle, paving the way for future clinical applications of this advanced imaging technique.
View Article and Find Full Text PDF

Background: Laparoscopic sleeve gastrectomy (LSG) became the most frequent bariatric procedure performed in France (2011) and in the United States (2013), but studies reporting long-term results are still rare.

Setting: Private hospital, France.

Methods: This is a retrospective analysis of a prospective cohort of 168 patients who underwent LSG between 2005 and 2008.

View Article and Find Full Text PDF

By acquiring tomographic measurements with several distinct photon energy spectra, spectral computed tomography (spectral CT) is able to provide additional material-specific information compared with conventional CT. This information enables the generation of material selective images, which have found various applications in medical imaging. However, material decomposition typically leads to noise amplification and a degradation of the signal-to-noise ratio.

View Article and Find Full Text PDF
Article Synopsis
  • X-ray chest radiography is commonly used for lung assessments but is not very sensitive for early pulmonary disease detection.
  • Recent studies of X-ray dark-field (XDF) imaging on mice show it significantly improves early diagnosis of conditions like chronic obstructive pulmonary disease (COPD) compared to standard radiography.
  • This study presents the first successful in-vivo XDF imaging of a pig's chest, paving the way for potential use in humans and indicating a shift in how lung conditions might be diagnosed in high-risk patients.
View Article and Find Full Text PDF