A rapid method for simultaneous determination of fluorine, chlorine and bromine in cement with ion chromatography after pyrolysis was proposed for routine quality control analysis. The elements were separated from cement sample by pyrolysis, and were subsequently determined with ion chromatography. A pyrolysis method was investigated for the separation of micro amounts of these elements from cement.

View Article and Find Full Text PDF

Using a spectrophotometric method after distillation separation is a standard test method widely employed for the determination of fluorine (F) in cement. Using a flow injection (FI) method after pyrolysis separation for quantification of fluorine in cement has recently been developed. Differences between the fluorine content values obtained by each method have been noted.

View Article and Find Full Text PDF

A detector for the simultaneous determination of choline (Ch) and acetylcholine (ACh) based on a sensitive trienzyme chemiluminometric biosensor in a single line flow injection (FI) system is described. Immobilized choline oxidase (ChOx), immobilized peroxidase (POx), immobilized acetylcholinesterase, and coimmobilized ChOx/POx were packed, in turn, in a transparent ETFE tube (1 mm i.d.

View Article and Find Full Text PDF

A chemiluminometric flow-through sensor for the simultaneous determination of glucose (Glu) and 3-hydroxybutyrate (HB) in a single sample has been developed. Coimmobilized 3-hydroxybutyrate dehydrogenase/NADH oxidase/peroxidase, a support material, and coimmobilized glucose dehydrogenase/NADH oxidase/peroxidase were packed sequentially in a transparent PTFE tube. The tube was then placed in front of a photomultiplier tube as a flow cell.

View Article and Find Full Text PDF

A micromachined flow cell (overall size; 25 x 25 x 1 mm3) was designed for the fast determination of hydrogen peroxide, based on a luminol-H2O2 chemiluminescence reaction catalyzed by immobilized peroxidase (POD). The flow cell consisted of a sandwich of anisotropically etched silicon and glass chips and contained a spiral channel (20 turns, 50 cm long, 150 microm wide, 20 microm depth, channel volume 1.4 microl) and two holes (1 mm diameter).

View Article and Find Full Text PDF

A chemiluminometric flow-through sensor for simultaneous determination of L-glutamate (Glu) and L-lysine (Lys) in a single sample has been developed. Immobilized uricase, immobilized peroxidase, support material, coimmobilized glutamate oxidase/peroxidase, support material, and coimmobilized lysine oxidase/peroxidase were packed sequentially in a transparent PTFE tube, and the tube was placed in front of a photomultiplier tube as a flow cell. A three-peak recording was obtained by one injection of the sample solution.