Japan has the highest estimated exposure frequency of diagnostic X-rays in the world. Furthermore, the volumetric computed tomography dose index (CTDIvol) and dose length product (DLP) of computed tomography coronary angiography are relatively high in Japanese diagnostic reference levels, and it is important to reduce both dose indices. This study proposed a new exposure reduction technique, the vanishing liver position (VLP), where the body is tilted to the right in the z-axis.
View Article and Find Full Text PDFIn this study, scaled scan band was developed to provide size-specific dose estimation (SSDE) values based on head circumference of patients undergoing computed tomography (CT) scans. The scan band was tested in 40 consecutive head CT examinations. The accuracy of the specialized scan band method was determined by comparing SSDEband with SSDE293,forehead, SSDEmean and SSDEcenter.
View Article and Find Full Text PDFRadiat Prot Dosimetry
December 2020
The risk in computed tomography (CT) examinations is radiation exposure. We aimed to develop a specialised tape measure for determining the size-specific dose estimate (SSDE) for patients undergoing CT scans. The scanning parameters used were those of the abdominal protocol in our institute.
View Article and Find Full Text PDFThe aim of this study is to evaluate the effect of table height displacement and patient center deviation along the [Formula: see text]-axis on size-specific dose estimate (SSDE) calculations based on computed tomography (CT) localizer radiographs in pediatric and adult abdominal CT examinations. CT localizer radiographs and CT axial images were acquired with table heights of - 5.0, - 2.
View Article and Find Full Text PDFObjective: The purpose of this study was to analyze in detail the quality of abdominal CT images obtained using three protocols reported by Image Gently in 2014 (hereafter referred to as Image Gently 2014), with the use of a handmade body phantom adapted to typical body sizes of the Japanese population. Moreover, we converted the findings of Image Gently 2014 to match Japanese body sizes and referred to our converted findings as Image Gently Japan.
Materials And Methods: We scanned each phantom in a mechanical isocenter in accordance with the Image Gently 2014 abdominal imaging protocol.
Nihon Hoshasen Gijutsu Gakkai Zasshi
September 2013
In recent years, development of advanced radiotherapy technology has resulted in an improvement in radiotherapy. Although the radiotherapy system has improved, the effect of the gap, the gyration center, and distortion of the rotation orbit cannot be neglected. Therefore, a verification method for a geometrical isocenter and rotation orbit in a three-dimension (3D) space is required.
View Article and Find Full Text PDF