In everyday dentistry, lithium disilicate is a valid option for single-fix partial dentures, and this material crystallization process is available with two protocols: long and short. This study's aim was to assess the effects of these two different crystallization protocols, long and short, on the marginal gap of lithium disilicate single crowns. A total of 24 abutment plastic teeth were scanned using an intra-oral scanner.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigated how sterilization impacts the measurements of implants in a straight line using two different scanning methods: laboratory scanners (LBS) and intra-oral scanners (IOS).
  • A 3D model was used to conduct multiple scans of a titanium intra-oral scan body (ISB) both before and after sterilization, with the results analyzed for discrepancies in measurements.
  • Findings revealed that sterilization significantly increased measurement errors for most implant distances and axes, highlighting the need for further research to establish guidelines on the sterilization of ISBs.
View Article and Find Full Text PDF

Purpose: Assess whether a Retroaortic left renal vein (RLRV) affects vertebral osteophyte formation in the lumbar spine, compared to normal anatomy left renal vein.

Methods: We conducted a retrospective case-control study. Computed tomography (CT) scans of individuals with a RLRV (study group) were compared to age- and gender-matched normal anatomy CT scans (control group).

View Article and Find Full Text PDF

: In everyday dentistry, monolithic single crowns can be cemented with self-adhesive resin cements. The aim of this in vitro study was to evaluate how the marginal adaptation of full monolithic zirconia-reinforced lithium silicate (ZLS) single crowns is influenced by three different self-adhesive resin cements. : Forty-five typodont teeth fully prepared for full monolithic crowns were divided into three groups (fifteen each) for the use of three different self-adhesive resin cements.

View Article and Find Full Text PDF

This study aimed to compare the impact of CAD/CAM closed systems and open systems on the marginal gap of monolithic zirconia-reinforced lithium silicate (ZLS) ceramic crowns, as both systems are used in everyday dentistry, both chair-side and laboratory. For the closed system, 20 plastic teeth were scanned by a Primescan intra-oral scanner (IOS), and for the open system, the same number of plastic teeth were scanned by Trios 4 IOS. For the closed system, CEREC software was used, and for the open system, EXOCAD software was used.

View Article and Find Full Text PDF

: In this study, we aimed to compare the effects of conventional and digital impressions on several parameters (inter-implant distance, intra-implant distance, inter-implant axis, and intra-implant axis) of three implants in curved lines and straight lines by using a laboratory scanner (LBS) versus an intra-oral scanner (IOS). : Two 3D models were fabricated using a printer, each model with three internal hex implants analogues at the positions of 15#,16#,17# (straight line) and 12#,13#,14# (curved line). Standard intra-oral scan bodies (ISBs) were used, and the two models were scanned using 7 Series dental wings (LBS, reference model), followed by ten scans with Primescan (digital method).

View Article and Find Full Text PDF

Background: This study compared the influence of crystallization on marginal gap adaptation by using computer-aided design and manufacturing (CAD-CAM) for producing monolithic zirconia-reinforced lithium silicate (ZLS) ceramic crowns.

Methods: A total of 25 plastic teeth were scanned using a Primescan intra-oral scanner (IOS), and ZLS crowns were ground. For each unit (abutment and crown), the marginal gap was evaluated pre crystallization and post crystallization at four regions of interest through the use of a scanning electron microscope (SEM).

View Article and Find Full Text PDF

The configuration of implant-supported prostheses is considered to influence the magnitude of stress concentrations, affecting their survival rate. The purpose of this study is to determine, through strain gauge measurements during load application, the dispersion and magnitude of strain concentrations in different implant-supported prosthesis designs. All designs matched those commonly used in posterior partially edentulous states.

View Article and Find Full Text PDF

Background: The purpose of this in vitro study was to compare the inter-implant distance, inter-implant axis, and intra-implant axis of three implants in a straight line by using a laboratory scanner (LBS) versus an intra-oral scanner (IOS) with two different intra-oral scan bodies (ISBs).

Methods: A 3D model was printed with internal hex implant analogs of three implants in positions 15#, 16#, and 17#. Two standard intra-oral scan bodies (ISBs) were used: MIS ISB (two-piece titanium) and Zirkonzhan ISB (two-piece titanium).

View Article and Find Full Text PDF

Even after a successful ventricular tachycardia ablation (VTA), some patients have recurrent ventricular tachycardia (VT) during their follow-up. We assessed the long-term predictors of recurrent VT after having a successful VTA. The patients who underwent a successful VTA (defined as the non-inducibility of any VT at the procedure's end) in 2014-2021 at our center in Israel were retrospectively analyzed.

View Article and Find Full Text PDF
Article Synopsis
  • Anti-PLA2R antibodies serve as a key diagnostic and prognostic biomarker in primary membranous nephropathy (PMN), indicating the severity and potential outcomes of the disease.
  • A study involving 41 PMN patients in Israel showed that higher levels of these antibodies at diagnosis correlate with increased proteinuria and lower serum albumin levels.
  • The research suggests that monitoring anti-PLA2R antibody levels can help predict remission and guide treatment strategies for PMN patients.
View Article and Find Full Text PDF

Caries development in children is a prevalent childhood disease. Factors affecting chronic teeth lesions include nutrition, parental involvement, and executing proper dental health attitude. Professional dentists are perceived as role models for the oral health and hygiene of their families.

View Article and Find Full Text PDF
Article Synopsis
  • - * Fibromyalgia syndrome (FMS) affects 2-4% of people and is associated with small fiber neuropathy (SFN) but lacks a clear cause; recent studies suggest a link between IgM antibodies and SFN.
  • - * A study measured anti-TS-HDS IgM levels in 30 women with FMS and 21 healthy women, revealing significantly lower levels in those with FMS.
  • - * The findings imply a possible connection between lower anti-TS-HDS IgM levels and FMS, potentially explaining the relationship between FMS and SFN, warranting further investigation. *
View Article and Find Full Text PDF

A failed implant site is prone to reduced alveolar bone volume, both horizontally and vertically. The present study assessed the outcome of using cancellous bone block allografts for ridge reconstruction following the removal of failed implants associated with severe bone loss. Individuals presenting with failed implants and massive bone loss were included.

View Article and Find Full Text PDF
Article Synopsis
  • Ventricular tachycardia ablation (VTA) is challenging when patients have low blood pressure, but using veno-arterial extracorporeal membrane oxygenation (VA-ECMO) can help complete the procedure safely.
  • A study gathered data from 46 patients who underwent VA-ECMO-assisted VTA, focusing on their medical history, procedure details, and outcomes, comparing those who were weaned off VA-ECMO immediately versus those who were not.
  • Results showed that early de-cannulation from VA-ECMO was linked to significantly better survival rates after one year, highlighting the importance of timely weaning to reduce mortality risk.
View Article and Find Full Text PDF

Background: Substantial effort is dedicated to finding the most favorable parameters that will ensure low aftercare demands among edentulous patients wearing mandibular implant supported overdentures (MISODs). The purpose of this retrospective cohort study was to compare prosthetic aftercare between MISOD patients with a simultaneous (group A) vs. a three-week settling in period (group B) prior to attachment incorporation.

View Article and Find Full Text PDF

Background: Individuals with tooth agenesis often present a significant clinical challenge for dental practitioners. This retrospective study evaluated clinical and radiological long-term functional and esthetic outcomes following restoration using primary teeth to support fixed all-ceramic prosthesis in patients with teeth agenesis.

Methods: Patients with teeth agenesis and at least one year follow-up were included.

View Article and Find Full Text PDF

Background: Dietary habits, food intake and oral health are important factors for general health. The aim of these present study was to assess the association between implant-supported fixed oral rehabilitation and glycemia, by monitoring HbA1c values before and after implant-supported prostheses (ISP) delivery to diabetic individuals. Methods: Retrospective, cohort study based on dental records.

View Article and Find Full Text PDF

Purpose: Evaluate the esthetic outcome of ridge augmentation using cancellous bone-block allografts, late implant placement, and immediate loading in the atrophic anterior maxilla, by PES (pink esthetic score) and WES (white esthetic score) indexes. Materials and Methods: Retrospective cohort study. Inclusion criteria were bone loss of at least 3 mm horizontally and 3 mm vertically according to preliminary CBCT; ridge augmentation using cancellous bone-block allografts; six months later the implant insertion and immediately loaded.

View Article and Find Full Text PDF

Purpose: Treatment alternatives based on implant-supported prostheses (ISPs) may be almost impossible in cases with extremely atrophic mandibles. Vertical bone augmentation is then the only possibility to achieve an ISP.

Materials And Methods: The consequences of vertical augmentation in extremely atrophic mandibles (≤ 10-mm bone height) of edentulous patients using allogeneic block grafts via a submental approach were assessed.

View Article and Find Full Text PDF

Background: Various conditions may lead to bony deficiency in the anterior maxilla. The present study evaluated esthetic (PES-pink esthetic score and WES-white esthetic score) results after augmentation of the anterior atrophic maxilla using cancellous bone-block allograft followed by implant placement and late (conventional) loading.

Methods: Cohort study that included 33 patients with missing teeth in the upper anterior region characterized by extensive bone loss.

View Article and Find Full Text PDF

Background: The purpose of the study was to analyze the efficacy of platelet-rich fibrin (PRF) as a single augmentation material for complicated cases of maxillary sinus floor elevation, resulting from membrane perforation or previous infections.

Methods: Implant insertion in the posterior region of the maxilla was simultaneously performed with maxillary sinus floor augmentation. Schneiderian membrane elevation can be accompanied by extremely serious sinus membrane perforation, due to accidental tearing or intended incision for mucocele removal.

View Article and Find Full Text PDF

Polymyositis (PM) and dermatomyositis (DM) are autoimmune-mediated multisystemic myopathies, characterized mainly by proximal muscle weakness. A connection between epilepsy and PM/DM has not been reported previously. Our study aim is to evaluate this association.

View Article and Find Full Text PDF