Listeria monocytogenes is an infrequent cause of bacterial myocarditis. Myocarditis without evidence of endocarditis is even rarer. Management in such cases involves early diagnosis, antibiotic therapy, and emergency treatment of arrhythmias.
View Article and Find Full Text PDFBackground: We examined the effect of novel oral anticoagulants (NOACs) compared to warfarin on the risk of death or stroke in atrial fibrillation (AF) patients in every day clinical practice.
Methods: We examined a cohort of 2,836 AF patients, of whom 2,253 were prescribed warfarin and 583 were prescribed an NOAC. Patients with glomerular filtration rate < 30 mg/mL or history of significant valvular heart disease were excluded.
Introduction: Post-cardiac arrest patients are often exposed to 100% oxygen during cardiopulmonary resuscitation and the early post-arrest period. It is unclear whether this contributes to development of pulmonary dysfunction or other patient outcomes.
Methods: We performed a retrospective cohort study including post-arrest patients who survived and were mechanically ventilated at least 24 hours after return of spontaneous circulation.
Background: Although guidelines for antiarrhythmic drug therapy in atrial fibrillation (AF) were published in 2006, it remains uncertain whether adherence to these guidelines affects patient outcomes.
Methods And Results: We retrospectively evaluated the records of 5976 consecutive AF patients who were prescribed at least 1 antiarrhythmic drug between 2006 and 2013. Patients with 1 or more prescribed antiarrhythmic drugs that did not comply with guideline recommendations comprised the non-guideline-directed group (=2920); the remainder constituted the guideline-directed group (=3056).
Purpose: Previous observational studies have inconsistently associated early hyperoxia with worse outcomes after cardiac arrest, and have methodological limitations. We tested this association using a high-resolution database controlling for multiple disease-specific markers of severity of illness and care processes.
Methods: This was a retrospective analysis of a single-center, prospective registry of consecutive cardiac arrest patients.
Aims: Given design similarities and a common manufacturer, there have been suspicions regarding the Durata™ defibrillator (ICD) lead, in the aftermath of the Riata™ class I recall. We therefore examined the failure-free survival rates of the Durata™ compared with the Riata™ and Sprint Quattro™ ICD leads.
Methods And Results: All patients (n = 2475) implanted with a Durata (n = 828), Riata [n = 627; 8 Fr.