Purpose: The study objective is to compare the outcomes of laparoscopic to tally extraperitoneal repair using the standard-weight polypropylene mesh or a lightweight titanium-coated mesh.
Methods: A retrospective review was conducted on 138 adult patients with unilateral inguinal hernias, who underwent totally extraperitoneal inguinal hernia repair between 2010 and 2013 using either a standard-weight polypropylene mesh (Prolene mesh, 80 g/m) or a lightweight titanium-coated mesh (Ti Mesh light, 35 g/m).
Results: There was no difference in reported pain at 24 hours postoperatively.