Objectives: To evaluate the long-term angiographic patency of saphenous vein grafts (SVG) harvested using the no-touch technique compared to the conventional technique.
Methods: This was a single-center, retrospective, cohort study. The inclusion criteria were individuals who underwent a CABG (coronary artery bypass grafting) between January 1995 and July 2020, and who successively needed a clinically-driven angiography.
Introduction: Conventional vein grafts have a high risk of thrombosis and early atherosclerosis. Percutaneous coronary intervention (PCI) in conventional vein grafts is associated with a higher incidence of late adverse cardiac events. The aim of this study was to evaluate the long-term results after PCI in saphenous vein grafts (SVG) harvested with the no-touch technique compared to the conventional technique.
View Article and Find Full Text PDFIntroduction: There is no consensus on the impact of coronary artery disease in patients undergoing transcatheter aortic valve implantation. Therefore, the objective of this study was, in a single-center setting, to evaluate the five-year outcome of transcatheter aortic valve implantation patients with or without coronary artery disease.
Methods: All transcatheter aortic valve implantation patients between 2009 and 2019 were included and grouped according to the presence or absence of coronary artery disease.
Background: Periprocedural stroke during transcatheter aortic valve implantation is a rare but devastating complication. The calcified aortic valve is the most likely source of the emboli in a periprocedural stroke. The total load and distribution of calcium in the leaflets, aortic root, and left ventricular outflow tract varies from patient to patient.
View Article and Find Full Text PDFObjective: To compare health-related quality of life (HRQoL) of patients primarily treated with a no-touch saphenous vein graft with that of patients who received a conventional graft.
Methods: The study included all individuals treated with a percutaneous coronary intervention (PCI) on a saphenous vein graft (SVG) between January 2006 and June 2020. The RAND-36 health survey was used to assess HRQoL.
Background: Randomized trials show high long-term patency for no-touch saphenous vein grafts in coronary artery bypass grafting. The patency rate in off-pump coronary bypass surgery for these grafts has not been investigated. Our center participated in the CORONARY randomized trial, NCT00463294.
View Article and Find Full Text PDFTo investigate the results of percutaneous coronary intervention (PCI) in saphenous vein grafts after coronary artery bypass grafting (CABG). MEDLINE, Embase, and the Cochrane library were searched for relevant articles published between 1 January 2000 and 29 February 2020. The PICO (population, intervention, comparison, outcome) model was applied in constructing the clinical question.
View Article and Find Full Text PDFSaphenous veins used for coronary artery bypass surgery are subjected to considerable vascular trauma when harvested by conventional methods. This vascular damage is responsible, at least in part, for the inferior patency of the saphenous vein when compared with the internal thoracic artery. The performance of saphenous vein grafts is improved when this conduit is harvested atraumatically using the no-touch technique.
View Article and Find Full Text PDFAsian Cardiovasc Thorac Ann
July 2021
Objective: Concerns have been raised regarding whether skeletonization of the internal thoracic artery could damage the graft and thereby reduces its patency. The objective of this study was to compare patency rates at mid- and long-term follow-up between pedicled and skeletonized left internal thoracic artery grafts.
Methods: This randomized controlled trial included 109 patients undergoing coronary artery bypass surgery.
Asian Cardiovasc Thorac Ann
June 2021
The saphenous vein is the most commonly used conduit for coronary artery bypass grafting. Arterial grafts are harvested with the outer pedicle intact whereas saphenous veins are harvested with the pedicle removed in the conventional graft harvesting technique. This conventional procedure causes considerable vascular damage.
View Article and Find Full Text PDFAdipose-derived mesenchymal stem cells (ADSCs) are promising candidates for novel cell therapeutic applications. Hibernating brown bears sustain tissue integrity and function via unknown mechanisms, which might be plasma borne. We hypothesized that plasma from hibernating bears may increase the expression of favorable factors from human ADSCs.
View Article and Find Full Text PDFThe saphenous vein is the most common conduit used in coronary artery bypass grafting (CABG) yet its failure rate is higher compared to arterial grafts. An improvement in saphenous vein graft performance is therefore a major priority in CABG. No-touch harvesting of the saphenous vein is one of the few interventions that has shown improved patency rates, comparable to that of the left internal thoracic artery.
View Article and Find Full Text PDFMesenchymal stem cells (MSCs) for cardiovascular cell therapy are procured from different sources including bone marrow and adipose tissue. Differently located MSCs differ in growth potential, differentiation ability and gene expression when cultured and studies show different healing abilities for different MSC subgroups. In this study, bone marrow derived MSCs (BMSCs) and adipose tissue derived MSCs (ADSCs) from six human donors with coronary artery disease were compared for growth potential and expression of target genes (Angpt1, LIF, HGF, TGF-β1 and VEGF-A) in response to exposure to 1% and 5% O, for up to 48 h.
View Article and Find Full Text PDFWith more than 800,000 coronary artery bypass grafting (CABG) operations annually worldwide and the saphenous vein being the most common conduit used, there is no question that improving saphenous vein graft patency is one of the most important tasks in CABG. This video describes the no-touch harvesting procedure of the saphenous vein on an 80-year old man with hypertension, hyperlipidemia and a previous myocardial infarction with percutaneous coronary intervention to the right coronary artery. He was complaining of exertional chest pain and was diagnosed with stable angina pectoris.
View Article and Find Full Text PDFIschemic heart disease is currently the leading cause of death globally, with coronary artery bypass grafting among the most common operations performed worldwide. More extensive use of arterial grafts has been advocated because of their high long-term patency, long-term survival benefit, and freedom from reinterventions. Despite this, the saphenous vein is the most frequently used conduit in patients undergoing coronary artery bypass surgery since its introduction over 50 years ago.
View Article and Find Full Text PDFObjectives: We investigated the patency rates of no-touch saphenous vein grafts anastomosed to the left anterior descending artery compared with the left internal thoracic artery. Further, we compared the patency of no-touch vein grafts to the left anterior descending artery with the patency of no-touch vein grafts to other coronary arteries.
Methods: Of 2635 consecutive patients undergoing coronary artery bypass grafting between 2003 and 2008, 168 (6.
Interact Cardiovasc Thorac Surg
March 2017
Objectives: The objective of this study was to investigate whether graft patency was associated with higher health-related quality of life in coronary artery bypass grafting patients and to compare this study with the general Swedish population.
Methods: Patients were included from 3 randomized trials and 1 prospective cohort trial. The generic health-related quality of life instrument, EQ-5D (VAS and index) was used.
Objectives: This study investigates whether the no-touch (NT) vein graft, at a mean time of 16 years, maintains a significantly higher patency rate than conventional (C) vein grafts and still has patency comparable to that of the left internal thoracic artery (LITA).
Methods: A total of 156 patients accepted for coronary artery bypass grafting were randomly allocated to 1 of 3 groups. In the C group, the saphenous vein (SV) was stripped and distended.
Objectives: To assess the left ventricular heart function and the clinical outcome 16 years after coronary artery bypass surgery.
Design: In a randomised trial, the no-touch (NT) vein graft in coronary artery bypass surgery has shown a superior patency rate, a slower progression of atherosclerosis and better clinical outcome compared to the conventional (C) vein graft at 8.5 years.